core/homeassistant/components/flexit/climate.py

207 lines
7.1 KiB
Python

"""Platform for Flexit AC units with CI66 Modbus adapter."""
from __future__ import annotations
import logging
from typing import Any
import voluptuous as vol
from homeassistant.components.climate import (
PLATFORM_SCHEMA as CLIMATE_PLATFORM_SCHEMA,
ClimateEntity,
ClimateEntityFeature,
HVACAction,
HVACMode,
)
from homeassistant.components.modbus import (
CALL_TYPE_REGISTER_HOLDING,
CALL_TYPE_REGISTER_INPUT,
DEFAULT_HUB,
ModbusHub,
get_hub,
)
from homeassistant.const import (
ATTR_TEMPERATURE,
CONF_NAME,
CONF_SLAVE,
DEVICE_DEFAULT_NAME,
UnitOfTemperature,
)
from homeassistant.core import HomeAssistant
import homeassistant.helpers.config_validation as cv
from homeassistant.helpers.entity_platform import AddEntitiesCallback
from homeassistant.helpers.typing import ConfigType, DiscoveryInfoType
CALL_TYPE_WRITE_REGISTER = "write_register"
CONF_HUB = "hub"
PLATFORM_SCHEMA = CLIMATE_PLATFORM_SCHEMA.extend(
{
vol.Optional(CONF_HUB, default=DEFAULT_HUB): cv.string,
vol.Required(CONF_SLAVE): vol.All(int, vol.Range(min=0, max=32)),
vol.Optional(CONF_NAME, default=DEVICE_DEFAULT_NAME): cv.string,
}
)
_LOGGER = logging.getLogger(__name__)
async def async_setup_platform(
hass: HomeAssistant,
config: ConfigType,
async_add_entities: AddEntitiesCallback,
discovery_info: DiscoveryInfoType | None = None,
) -> None:
"""Set up the Flexit Platform."""
modbus_slave = config.get(CONF_SLAVE)
name = config.get(CONF_NAME)
hub = get_hub(hass, config[CONF_HUB])
async_add_entities([Flexit(hub, modbus_slave, name)], True)
class Flexit(ClimateEntity):
"""Representation of a Flexit AC unit."""
_attr_fan_modes = ["Off", "Low", "Medium", "High"]
_attr_hvac_mode = HVACMode.COOL
_attr_hvac_modes = [HVACMode.COOL]
_attr_supported_features = (
ClimateEntityFeature.TARGET_TEMPERATURE | ClimateEntityFeature.FAN_MODE
)
_attr_temperature_unit = UnitOfTemperature.CELSIUS
_enable_turn_on_off_backwards_compatibility = False
def __init__(
self, hub: ModbusHub, modbus_slave: int | None, name: str | None
) -> None:
"""Initialize the unit."""
self._hub = hub
self._attr_name = name
self._slave = modbus_slave
self._attr_fan_mode = None
self._filter_hours: int | None = None
self._filter_alarm: int | None = None
self._heat_recovery: int | None = None
self._heater_enabled: int | None = None
self._heating: int | None = None
self._cooling: int | None = None
self._alarm = False
self._outdoor_air_temp: float | None = None
async def async_update(self) -> None:
"""Update unit attributes."""
self._attr_target_temperature = await self._async_read_temp_from_register(
CALL_TYPE_REGISTER_HOLDING, 8
)
self._attr_current_temperature = await self._async_read_temp_from_register(
CALL_TYPE_REGISTER_INPUT, 9
)
res = await self._async_read_int16_from_register(CALL_TYPE_REGISTER_HOLDING, 17)
if self.fan_modes and res < len(self.fan_modes):
self._attr_fan_mode = self.fan_modes[res]
self._filter_hours = await self._async_read_int16_from_register(
CALL_TYPE_REGISTER_INPUT, 8
)
# # Mechanical heat recovery, 0-100%
self._heat_recovery = await self._async_read_int16_from_register(
CALL_TYPE_REGISTER_INPUT, 14
)
# # Heater active 0-100%
self._heating = await self._async_read_int16_from_register(
CALL_TYPE_REGISTER_INPUT, 15
)
# # Cooling active 0-100%
self._cooling = await self._async_read_int16_from_register(
CALL_TYPE_REGISTER_INPUT, 13
)
# # Filter alarm 0/1
self._filter_alarm = await self._async_read_int16_from_register(
CALL_TYPE_REGISTER_INPUT, 27
)
# # Heater enabled or not. Does not mean it's necessarily heating
self._heater_enabled = await self._async_read_int16_from_register(
CALL_TYPE_REGISTER_INPUT, 28
)
self._outdoor_air_temp = await self._async_read_temp_from_register(
CALL_TYPE_REGISTER_INPUT, 11
)
actual_air_speed = await self._async_read_int16_from_register(
CALL_TYPE_REGISTER_INPUT, 48
)
if self._heating:
self._attr_hvac_action = HVACAction.HEATING
elif self._cooling:
self._attr_hvac_action = HVACAction.COOLING
elif self._heat_recovery:
self._attr_hvac_action = HVACAction.IDLE
elif actual_air_speed:
self._attr_hvac_action = HVACAction.FAN
else:
self._attr_hvac_action = HVACAction.OFF
@property
def extra_state_attributes(self) -> dict[str, Any]:
"""Return device specific state attributes."""
return {
"filter_hours": self._filter_hours,
"filter_alarm": self._filter_alarm,
"heat_recovery": self._heat_recovery,
"heating": self._heating,
"heater_enabled": self._heater_enabled,
"cooling": self._cooling,
"outdoor_air_temp": self._outdoor_air_temp,
}
async def async_set_temperature(self, **kwargs: Any) -> None:
"""Set new target temperature."""
if (target_temperature := kwargs.get(ATTR_TEMPERATURE)) is None:
_LOGGER.error("Received invalid temperature")
return
if await self._async_write_int16_to_register(8, int(target_temperature * 10)):
self._attr_target_temperature = target_temperature
else:
_LOGGER.error("Modbus error setting target temperature to Flexit")
async def async_set_fan_mode(self, fan_mode: str) -> None:
"""Set new fan mode."""
if self.fan_modes and await self._async_write_int16_to_register(
17, self.fan_modes.index(fan_mode)
):
self._attr_fan_mode = fan_mode
else:
_LOGGER.error("Modbus error setting fan mode to Flexit")
# Based on _async_read_register in ModbusThermostat class
async def _async_read_int16_from_register(
self, register_type: str, register: int
) -> int:
"""Read register using the Modbus hub slave."""
result = await self._hub.async_pb_call(self._slave, register, 1, register_type)
if result is None:
_LOGGER.error("Error reading value from Flexit modbus adapter")
return -1
return int(result.registers[0])
async def _async_read_temp_from_register(
self, register_type: str, register: int
) -> float:
result = float(
await self._async_read_int16_from_register(register_type, register)
)
if not result:
return -1
return result / 10.0
async def _async_write_int16_to_register(self, register: int, value: int) -> bool:
result = await self._hub.async_pb_call(
self._slave, register, value, CALL_TYPE_WRITE_REGISTER
)
if not result:
return False
return True