core/homeassistant/components/nibe_heatpump/config_flow.py

231 lines
7.2 KiB
Python

"""Config flow for Nibe Heat Pump integration."""
from __future__ import annotations
from typing import Any
from nibe.connection.modbus import Modbus
from nibe.connection.nibegw import NibeGW
from nibe.exceptions import (
AddressInUseException,
CoilNotFoundException,
CoilWriteSendException,
ReadException,
ReadSendException,
WriteException,
)
from nibe.heatpump import HeatPump, Model
import voluptuous as vol
import yarl
from homeassistant.config_entries import ConfigFlow, ConfigFlowResult
from homeassistant.const import CONF_IP_ADDRESS, CONF_MODEL
from homeassistant.core import HomeAssistant
from homeassistant.helpers import selector
from .const import (
CONF_CONNECTION_TYPE,
CONF_CONNECTION_TYPE_MODBUS,
CONF_CONNECTION_TYPE_NIBEGW,
CONF_LISTENING_PORT,
CONF_MODBUS_UNIT,
CONF_MODBUS_URL,
CONF_REMOTE_READ_PORT,
CONF_REMOTE_WRITE_PORT,
CONF_WORD_SWAP,
DOMAIN,
LOGGER,
)
PORT_SELECTOR = vol.All(
selector.NumberSelector(
selector.NumberSelectorConfig(
min=1, step=1, max=65535, mode=selector.NumberSelectorMode.BOX
)
),
vol.Coerce(int),
)
STEP_NIBEGW_DATA_SCHEMA = vol.Schema(
{
vol.Required(CONF_MODEL): vol.In(list(Model.__members__)),
vol.Required(CONF_IP_ADDRESS): selector.TextSelector(),
vol.Required(CONF_LISTENING_PORT, default=9999): PORT_SELECTOR,
vol.Required(CONF_REMOTE_READ_PORT, default=9999): PORT_SELECTOR,
vol.Required(CONF_REMOTE_WRITE_PORT, default=10000): PORT_SELECTOR,
}
)
STEP_MODBUS_DATA_SCHEMA = vol.Schema(
{
vol.Required(CONF_MODEL): vol.In(list(Model.__members__)),
vol.Required(CONF_MODBUS_URL): selector.TextSelector(),
vol.Required(CONF_MODBUS_UNIT, default=0): vol.All(
selector.NumberSelector(
selector.NumberSelectorConfig(
min=0, step=1, mode=selector.NumberSelectorMode.BOX
)
),
vol.Coerce(int),
),
}
)
class FieldError(Exception):
"""Field with invalid data."""
def __init__(self, message: str, field: str, error: str) -> None:
"""Set up error."""
super().__init__(message)
self.field = field
self.error = error
async def validate_nibegw_input(
hass: HomeAssistant, data: dict[str, Any]
) -> tuple[str, dict[str, Any]]:
"""Validate the user input allows us to connect."""
heatpump = HeatPump(Model[data[CONF_MODEL]])
heatpump.word_swap = True
await heatpump.initialize()
connection = NibeGW(
heatpump,
data[CONF_IP_ADDRESS],
data[CONF_REMOTE_READ_PORT],
data[CONF_REMOTE_WRITE_PORT],
listening_port=data[CONF_LISTENING_PORT],
)
try:
await connection.start()
except AddressInUseException as exception:
raise FieldError(
"Address already in use", "listening_port", "address_in_use"
) from exception
try:
await connection.verify_connectivity()
except (ReadSendException, CoilWriteSendException) as exception:
raise FieldError(str(exception), CONF_IP_ADDRESS, "address") from exception
except CoilNotFoundException as exception:
raise FieldError("Coils not found", "base", "model") from exception
except ReadException as exception:
raise FieldError("Timeout on read from pump", "base", "read") from exception
except WriteException as exception:
raise FieldError("Timeout on writing to pump", "base", "write") from exception
finally:
await connection.stop()
return f"{data[CONF_MODEL]} at {data[CONF_IP_ADDRESS]}", {
**data,
CONF_WORD_SWAP: heatpump.word_swap,
CONF_CONNECTION_TYPE: CONF_CONNECTION_TYPE_NIBEGW,
}
async def validate_modbus_input(
hass: HomeAssistant, data: dict[str, Any]
) -> tuple[str, dict[str, Any]]:
"""Validate the user input allows us to connect."""
heatpump = HeatPump(Model[data[CONF_MODEL]])
await heatpump.initialize()
try:
connection = Modbus(
heatpump,
data[CONF_MODBUS_URL],
data[CONF_MODBUS_UNIT],
)
except ValueError as exc:
raise FieldError("Not a valid modbus url", CONF_MODBUS_URL, "url") from exc
await connection.start()
try:
await connection.verify_connectivity()
except (ReadSendException, CoilWriteSendException) as exception:
raise FieldError(str(exception), CONF_MODBUS_URL, "address") from exception
except CoilNotFoundException as exception:
raise FieldError("Coils not found", "base", "model") from exception
except ReadException as exception:
raise FieldError("Timeout on read from pump", "base", "read") from exception
except WriteException as exception:
raise FieldError("Timeout on writing to pump", "base", "write") from exception
finally:
await connection.stop()
host = yarl.URL(data[CONF_MODBUS_URL]).host
return f"{data[CONF_MODEL]} at {host}", {
**data,
CONF_CONNECTION_TYPE: CONF_CONNECTION_TYPE_MODBUS,
}
class NibeHeatPumpConfigFlow(ConfigFlow, domain=DOMAIN):
"""Handle a config flow for Nibe Heat Pump."""
VERSION = 1
async def async_step_user(
self, user_input: dict[str, Any] | None = None
) -> ConfigFlowResult:
"""Handle the initial step."""
return self.async_show_menu(step_id="user", menu_options=["modbus", "nibegw"])
async def async_step_modbus(
self, user_input: dict[str, Any] | None = None
) -> ConfigFlowResult:
"""Handle the modbus step."""
if user_input is None:
return self.async_show_form(
step_id="modbus", data_schema=STEP_MODBUS_DATA_SCHEMA
)
errors = {}
try:
title, data = await validate_modbus_input(self.hass, user_input)
except FieldError as exception:
LOGGER.debug("Validation error %s", exception)
errors[exception.field] = exception.error
except Exception: # noqa: BLE001
LOGGER.exception("Unexpected exception")
errors["base"] = "unknown"
else:
return self.async_create_entry(title=title, data=data)
return self.async_show_form(
step_id="modbus", data_schema=STEP_MODBUS_DATA_SCHEMA, errors=errors
)
async def async_step_nibegw(
self, user_input: dict[str, Any] | None = None
) -> ConfigFlowResult:
"""Handle the nibegw step."""
if user_input is None:
return self.async_show_form(
step_id="nibegw", data_schema=STEP_NIBEGW_DATA_SCHEMA
)
errors = {}
try:
title, data = await validate_nibegw_input(self.hass, user_input)
except FieldError as exception:
LOGGER.exception("Validation error")
errors[exception.field] = exception.error
except Exception: # noqa: BLE001
LOGGER.exception("Unexpected exception")
errors["base"] = "unknown"
else:
return self.async_create_entry(title=title, data=data)
return self.async_show_form(
step_id="nibegw", data_schema=STEP_NIBEGW_DATA_SCHEMA, errors=errors
)