"""Config flow for Nibe Heat Pump integration."""
|
|
|
|
from __future__ import annotations
|
|
|
|
from typing import Any
|
|
|
|
from nibe.connection.modbus import Modbus
|
|
from nibe.connection.nibegw import NibeGW
|
|
from nibe.exceptions import (
|
|
AddressInUseException,
|
|
CoilNotFoundException,
|
|
CoilWriteSendException,
|
|
ReadException,
|
|
ReadSendException,
|
|
WriteException,
|
|
)
|
|
from nibe.heatpump import HeatPump, Model
|
|
import voluptuous as vol
|
|
import yarl
|
|
|
|
from homeassistant.config_entries import ConfigFlow, ConfigFlowResult
|
|
from homeassistant.const import CONF_IP_ADDRESS, CONF_MODEL
|
|
from homeassistant.core import HomeAssistant
|
|
from homeassistant.helpers import selector
|
|
|
|
from .const import (
|
|
CONF_CONNECTION_TYPE,
|
|
CONF_CONNECTION_TYPE_MODBUS,
|
|
CONF_CONNECTION_TYPE_NIBEGW,
|
|
CONF_LISTENING_PORT,
|
|
CONF_MODBUS_UNIT,
|
|
CONF_MODBUS_URL,
|
|
CONF_REMOTE_READ_PORT,
|
|
CONF_REMOTE_WRITE_PORT,
|
|
CONF_WORD_SWAP,
|
|
DOMAIN,
|
|
LOGGER,
|
|
)
|
|
|
|
PORT_SELECTOR = vol.All(
|
|
selector.NumberSelector(
|
|
selector.NumberSelectorConfig(
|
|
min=1, step=1, max=65535, mode=selector.NumberSelectorMode.BOX
|
|
)
|
|
),
|
|
vol.Coerce(int),
|
|
)
|
|
|
|
STEP_NIBEGW_DATA_SCHEMA = vol.Schema(
|
|
{
|
|
vol.Required(CONF_MODEL): vol.In(list(Model.__members__)),
|
|
vol.Required(CONF_IP_ADDRESS): selector.TextSelector(),
|
|
vol.Required(CONF_LISTENING_PORT, default=9999): PORT_SELECTOR,
|
|
vol.Required(CONF_REMOTE_READ_PORT, default=9999): PORT_SELECTOR,
|
|
vol.Required(CONF_REMOTE_WRITE_PORT, default=10000): PORT_SELECTOR,
|
|
}
|
|
)
|
|
|
|
|
|
STEP_MODBUS_DATA_SCHEMA = vol.Schema(
|
|
{
|
|
vol.Required(CONF_MODEL): vol.In(list(Model.__members__)),
|
|
vol.Required(CONF_MODBUS_URL): selector.TextSelector(),
|
|
vol.Required(CONF_MODBUS_UNIT, default=0): vol.All(
|
|
selector.NumberSelector(
|
|
selector.NumberSelectorConfig(
|
|
min=0, step=1, mode=selector.NumberSelectorMode.BOX
|
|
)
|
|
),
|
|
vol.Coerce(int),
|
|
),
|
|
}
|
|
)
|
|
|
|
|
|
class FieldError(Exception):
|
|
"""Field with invalid data."""
|
|
|
|
def __init__(self, message: str, field: str, error: str) -> None:
|
|
"""Set up error."""
|
|
super().__init__(message)
|
|
self.field = field
|
|
self.error = error
|
|
|
|
|
|
async def validate_nibegw_input(
|
|
hass: HomeAssistant, data: dict[str, Any]
|
|
) -> tuple[str, dict[str, Any]]:
|
|
"""Validate the user input allows us to connect."""
|
|
|
|
heatpump = HeatPump(Model[data[CONF_MODEL]])
|
|
heatpump.word_swap = True
|
|
await heatpump.initialize()
|
|
|
|
connection = NibeGW(
|
|
heatpump,
|
|
data[CONF_IP_ADDRESS],
|
|
data[CONF_REMOTE_READ_PORT],
|
|
data[CONF_REMOTE_WRITE_PORT],
|
|
listening_port=data[CONF_LISTENING_PORT],
|
|
)
|
|
|
|
try:
|
|
await connection.start()
|
|
except AddressInUseException as exception:
|
|
raise FieldError(
|
|
"Address already in use", "listening_port", "address_in_use"
|
|
) from exception
|
|
|
|
try:
|
|
await connection.verify_connectivity()
|
|
except (ReadSendException, CoilWriteSendException) as exception:
|
|
raise FieldError(str(exception), CONF_IP_ADDRESS, "address") from exception
|
|
except CoilNotFoundException as exception:
|
|
raise FieldError("Coils not found", "base", "model") from exception
|
|
except ReadException as exception:
|
|
raise FieldError("Timeout on read from pump", "base", "read") from exception
|
|
except WriteException as exception:
|
|
raise FieldError("Timeout on writing to pump", "base", "write") from exception
|
|
finally:
|
|
await connection.stop()
|
|
|
|
return f"{data[CONF_MODEL]} at {data[CONF_IP_ADDRESS]}", {
|
|
**data,
|
|
CONF_WORD_SWAP: heatpump.word_swap,
|
|
CONF_CONNECTION_TYPE: CONF_CONNECTION_TYPE_NIBEGW,
|
|
}
|
|
|
|
|
|
async def validate_modbus_input(
|
|
hass: HomeAssistant, data: dict[str, Any]
|
|
) -> tuple[str, dict[str, Any]]:
|
|
"""Validate the user input allows us to connect."""
|
|
|
|
heatpump = HeatPump(Model[data[CONF_MODEL]])
|
|
await heatpump.initialize()
|
|
|
|
try:
|
|
connection = Modbus(
|
|
heatpump,
|
|
data[CONF_MODBUS_URL],
|
|
data[CONF_MODBUS_UNIT],
|
|
)
|
|
except ValueError as exc:
|
|
raise FieldError("Not a valid modbus url", CONF_MODBUS_URL, "url") from exc
|
|
|
|
await connection.start()
|
|
|
|
try:
|
|
await connection.verify_connectivity()
|
|
except (ReadSendException, CoilWriteSendException) as exception:
|
|
raise FieldError(str(exception), CONF_MODBUS_URL, "address") from exception
|
|
except CoilNotFoundException as exception:
|
|
raise FieldError("Coils not found", "base", "model") from exception
|
|
except ReadException as exception:
|
|
raise FieldError("Timeout on read from pump", "base", "read") from exception
|
|
except WriteException as exception:
|
|
raise FieldError("Timeout on writing to pump", "base", "write") from exception
|
|
finally:
|
|
await connection.stop()
|
|
|
|
host = yarl.URL(data[CONF_MODBUS_URL]).host
|
|
return f"{data[CONF_MODEL]} at {host}", {
|
|
**data,
|
|
CONF_CONNECTION_TYPE: CONF_CONNECTION_TYPE_MODBUS,
|
|
}
|
|
|
|
|
|
class NibeHeatPumpConfigFlow(ConfigFlow, domain=DOMAIN):
|
|
"""Handle a config flow for Nibe Heat Pump."""
|
|
|
|
VERSION = 1
|
|
|
|
async def async_step_user(
|
|
self, user_input: dict[str, Any] | None = None
|
|
) -> ConfigFlowResult:
|
|
"""Handle the initial step."""
|
|
return self.async_show_menu(step_id="user", menu_options=["modbus", "nibegw"])
|
|
|
|
async def async_step_modbus(
|
|
self, user_input: dict[str, Any] | None = None
|
|
) -> ConfigFlowResult:
|
|
"""Handle the modbus step."""
|
|
if user_input is None:
|
|
return self.async_show_form(
|
|
step_id="modbus", data_schema=STEP_MODBUS_DATA_SCHEMA
|
|
)
|
|
|
|
errors = {}
|
|
|
|
try:
|
|
title, data = await validate_modbus_input(self.hass, user_input)
|
|
except FieldError as exception:
|
|
LOGGER.debug("Validation error %s", exception)
|
|
errors[exception.field] = exception.error
|
|
except Exception: # noqa: BLE001
|
|
LOGGER.exception("Unexpected exception")
|
|
errors["base"] = "unknown"
|
|
else:
|
|
return self.async_create_entry(title=title, data=data)
|
|
|
|
return self.async_show_form(
|
|
step_id="modbus", data_schema=STEP_MODBUS_DATA_SCHEMA, errors=errors
|
|
)
|
|
|
|
async def async_step_nibegw(
|
|
self, user_input: dict[str, Any] | None = None
|
|
) -> ConfigFlowResult:
|
|
"""Handle the nibegw step."""
|
|
if user_input is None:
|
|
return self.async_show_form(
|
|
step_id="nibegw", data_schema=STEP_NIBEGW_DATA_SCHEMA
|
|
)
|
|
|
|
errors = {}
|
|
|
|
try:
|
|
title, data = await validate_nibegw_input(self.hass, user_input)
|
|
except FieldError as exception:
|
|
LOGGER.exception("Validation error")
|
|
errors[exception.field] = exception.error
|
|
except Exception: # noqa: BLE001
|
|
LOGGER.exception("Unexpected exception")
|
|
errors["base"] = "unknown"
|
|
else:
|
|
return self.async_create_entry(title=title, data=data)
|
|
|
|
return self.async_show_form(
|
|
step_id="nibegw", data_schema=STEP_NIBEGW_DATA_SCHEMA, errors=errors
|
|
)
|