"""Support for Peblar sensors."""
|
|
|
|
from __future__ import annotations
|
|
|
|
from collections.abc import Callable
|
|
from dataclasses import dataclass
|
|
from datetime import datetime, timedelta
|
|
|
|
from peblar import PeblarUserConfiguration
|
|
|
|
from homeassistant.components.sensor import (
|
|
SensorDeviceClass,
|
|
SensorEntity,
|
|
SensorEntityDescription,
|
|
SensorStateClass,
|
|
)
|
|
from homeassistant.const import (
|
|
EntityCategory,
|
|
UnitOfElectricCurrent,
|
|
UnitOfElectricPotential,
|
|
UnitOfEnergy,
|
|
UnitOfPower,
|
|
)
|
|
from homeassistant.core import HomeAssistant
|
|
from homeassistant.helpers.entity_platform import AddEntitiesCallback
|
|
from homeassistant.util.dt import utcnow
|
|
|
|
from .const import (
|
|
PEBLAR_CHARGE_LIMITER_TO_HOME_ASSISTANT,
|
|
PEBLAR_CP_STATE_TO_HOME_ASSISTANT,
|
|
)
|
|
from .coordinator import PeblarConfigEntry, PeblarData, PeblarDataUpdateCoordinator
|
|
from .entity import PeblarEntity
|
|
|
|
PARALLEL_UPDATES = 0
|
|
|
|
|
|
@dataclass(frozen=True, kw_only=True)
|
|
class PeblarSensorDescription(SensorEntityDescription):
|
|
"""Describe a Peblar sensor."""
|
|
|
|
has_fn: Callable[[PeblarUserConfiguration], bool] = lambda _: True
|
|
value_fn: Callable[[PeblarData], datetime | int | str | None]
|
|
|
|
|
|
DESCRIPTIONS: tuple[PeblarSensorDescription, ...] = (
|
|
PeblarSensorDescription(
|
|
key="cp_state",
|
|
translation_key="cp_state",
|
|
device_class=SensorDeviceClass.ENUM,
|
|
options=list(PEBLAR_CP_STATE_TO_HOME_ASSISTANT.values()),
|
|
value_fn=lambda x: PEBLAR_CP_STATE_TO_HOME_ASSISTANT[x.ev.cp_state],
|
|
),
|
|
PeblarSensorDescription(
|
|
key="charge_current_limit_source",
|
|
translation_key="charge_current_limit_source",
|
|
device_class=SensorDeviceClass.ENUM,
|
|
entity_category=EntityCategory.DIAGNOSTIC,
|
|
options=list(PEBLAR_CHARGE_LIMITER_TO_HOME_ASSISTANT.values()),
|
|
value_fn=lambda x: PEBLAR_CHARGE_LIMITER_TO_HOME_ASSISTANT[
|
|
x.ev.charge_current_limit_source
|
|
],
|
|
),
|
|
PeblarSensorDescription(
|
|
key="current_total",
|
|
device_class=SensorDeviceClass.CURRENT,
|
|
entity_category=EntityCategory.DIAGNOSTIC,
|
|
entity_registry_enabled_default=False,
|
|
native_unit_of_measurement=UnitOfElectricCurrent.MILLIAMPERE,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
suggested_display_precision=1,
|
|
suggested_unit_of_measurement=UnitOfElectricCurrent.AMPERE,
|
|
value_fn=lambda x: x.meter.current_total,
|
|
),
|
|
PeblarSensorDescription(
|
|
key="current_phase_1",
|
|
translation_key="current_phase_1",
|
|
device_class=SensorDeviceClass.CURRENT,
|
|
entity_category=EntityCategory.DIAGNOSTIC,
|
|
entity_registry_enabled_default=False,
|
|
has_fn=lambda x: x.connected_phases >= 2,
|
|
native_unit_of_measurement=UnitOfElectricCurrent.MILLIAMPERE,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
suggested_display_precision=1,
|
|
suggested_unit_of_measurement=UnitOfElectricCurrent.AMPERE,
|
|
value_fn=lambda x: x.meter.current_phase_1,
|
|
),
|
|
PeblarSensorDescription(
|
|
key="current_phase_2",
|
|
translation_key="current_phase_2",
|
|
device_class=SensorDeviceClass.CURRENT,
|
|
entity_category=EntityCategory.DIAGNOSTIC,
|
|
entity_registry_enabled_default=False,
|
|
has_fn=lambda x: x.connected_phases >= 2,
|
|
native_unit_of_measurement=UnitOfElectricCurrent.MILLIAMPERE,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
suggested_display_precision=1,
|
|
suggested_unit_of_measurement=UnitOfElectricCurrent.AMPERE,
|
|
value_fn=lambda x: x.meter.current_phase_2,
|
|
),
|
|
PeblarSensorDescription(
|
|
key="current_phase_3",
|
|
translation_key="current_phase_3",
|
|
device_class=SensorDeviceClass.CURRENT,
|
|
entity_category=EntityCategory.DIAGNOSTIC,
|
|
entity_registry_enabled_default=False,
|
|
has_fn=lambda x: x.connected_phases == 3,
|
|
native_unit_of_measurement=UnitOfElectricCurrent.MILLIAMPERE,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
suggested_display_precision=1,
|
|
suggested_unit_of_measurement=UnitOfElectricCurrent.AMPERE,
|
|
value_fn=lambda x: x.meter.current_phase_3,
|
|
),
|
|
PeblarSensorDescription(
|
|
key="energy_session",
|
|
translation_key="energy_session",
|
|
device_class=SensorDeviceClass.ENERGY,
|
|
native_unit_of_measurement=UnitOfEnergy.WATT_HOUR,
|
|
state_class=SensorStateClass.TOTAL_INCREASING,
|
|
suggested_display_precision=2,
|
|
suggested_unit_of_measurement=UnitOfEnergy.KILO_WATT_HOUR,
|
|
value_fn=lambda x: x.meter.energy_session,
|
|
),
|
|
PeblarSensorDescription(
|
|
key="energy_total",
|
|
translation_key="energy_total",
|
|
device_class=SensorDeviceClass.ENERGY,
|
|
entity_category=EntityCategory.DIAGNOSTIC,
|
|
native_unit_of_measurement=UnitOfEnergy.WATT_HOUR,
|
|
state_class=SensorStateClass.TOTAL_INCREASING,
|
|
suggested_display_precision=2,
|
|
suggested_unit_of_measurement=UnitOfEnergy.KILO_WATT_HOUR,
|
|
value_fn=lambda x: x.meter.energy_total,
|
|
),
|
|
PeblarSensorDescription(
|
|
key="power_total",
|
|
device_class=SensorDeviceClass.POWER,
|
|
native_unit_of_measurement=UnitOfPower.WATT,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
value_fn=lambda x: x.meter.power_total,
|
|
),
|
|
PeblarSensorDescription(
|
|
key="power_phase_1",
|
|
translation_key="power_phase_1",
|
|
device_class=SensorDeviceClass.POWER,
|
|
entity_category=EntityCategory.DIAGNOSTIC,
|
|
entity_registry_enabled_default=False,
|
|
has_fn=lambda x: x.connected_phases >= 2,
|
|
native_unit_of_measurement=UnitOfPower.WATT,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
value_fn=lambda x: x.meter.power_phase_1,
|
|
),
|
|
PeblarSensorDescription(
|
|
key="power_phase_2",
|
|
translation_key="power_phase_2",
|
|
device_class=SensorDeviceClass.POWER,
|
|
entity_category=EntityCategory.DIAGNOSTIC,
|
|
entity_registry_enabled_default=False,
|
|
has_fn=lambda x: x.connected_phases >= 2,
|
|
native_unit_of_measurement=UnitOfPower.WATT,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
value_fn=lambda x: x.meter.power_phase_2,
|
|
),
|
|
PeblarSensorDescription(
|
|
key="power_phase_3",
|
|
translation_key="power_phase_3",
|
|
device_class=SensorDeviceClass.POWER,
|
|
entity_category=EntityCategory.DIAGNOSTIC,
|
|
entity_registry_enabled_default=False,
|
|
has_fn=lambda x: x.connected_phases == 3,
|
|
native_unit_of_measurement=UnitOfPower.WATT,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
value_fn=lambda x: x.meter.power_phase_3,
|
|
),
|
|
PeblarSensorDescription(
|
|
key="voltage",
|
|
device_class=SensorDeviceClass.VOLTAGE,
|
|
entity_category=EntityCategory.DIAGNOSTIC,
|
|
entity_registry_enabled_default=False,
|
|
has_fn=lambda x: x.connected_phases == 1,
|
|
native_unit_of_measurement=UnitOfElectricPotential.VOLT,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
value_fn=lambda x: x.meter.voltage_phase_1,
|
|
),
|
|
PeblarSensorDescription(
|
|
key="voltage_phase_1",
|
|
translation_key="voltage_phase_1",
|
|
device_class=SensorDeviceClass.VOLTAGE,
|
|
entity_category=EntityCategory.DIAGNOSTIC,
|
|
entity_registry_enabled_default=False,
|
|
has_fn=lambda x: x.connected_phases >= 2,
|
|
native_unit_of_measurement=UnitOfElectricPotential.VOLT,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
value_fn=lambda x: x.meter.voltage_phase_1,
|
|
),
|
|
PeblarSensorDescription(
|
|
key="voltage_phase_2",
|
|
translation_key="voltage_phase_2",
|
|
device_class=SensorDeviceClass.VOLTAGE,
|
|
entity_category=EntityCategory.DIAGNOSTIC,
|
|
entity_registry_enabled_default=False,
|
|
has_fn=lambda x: x.connected_phases >= 2,
|
|
native_unit_of_measurement=UnitOfElectricPotential.VOLT,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
value_fn=lambda x: x.meter.voltage_phase_2,
|
|
),
|
|
PeblarSensorDescription(
|
|
key="voltage_phase_3",
|
|
translation_key="voltage_phase_3",
|
|
device_class=SensorDeviceClass.VOLTAGE,
|
|
entity_category=EntityCategory.DIAGNOSTIC,
|
|
entity_registry_enabled_default=False,
|
|
has_fn=lambda x: x.connected_phases == 3,
|
|
native_unit_of_measurement=UnitOfElectricPotential.VOLT,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
value_fn=lambda x: x.meter.voltage_phase_3,
|
|
),
|
|
PeblarSensorDescription(
|
|
key="uptime",
|
|
translation_key="uptime",
|
|
device_class=SensorDeviceClass.TIMESTAMP,
|
|
entity_category=EntityCategory.DIAGNOSTIC,
|
|
entity_registry_enabled_default=False,
|
|
value_fn=lambda x: (
|
|
utcnow().replace(microsecond=0) - timedelta(seconds=x.system.uptime)
|
|
),
|
|
),
|
|
)
|
|
|
|
|
|
async def async_setup_entry(
|
|
hass: HomeAssistant,
|
|
entry: PeblarConfigEntry,
|
|
async_add_entities: AddEntitiesCallback,
|
|
) -> None:
|
|
"""Set up Peblar sensors based on a config entry."""
|
|
async_add_entities(
|
|
PeblarSensorEntity(
|
|
entry=entry,
|
|
coordinator=entry.runtime_data.data_coordinator,
|
|
description=description,
|
|
)
|
|
for description in DESCRIPTIONS
|
|
if description.has_fn(entry.runtime_data.user_configuration_coordinator.data)
|
|
)
|
|
|
|
|
|
class PeblarSensorEntity(PeblarEntity[PeblarDataUpdateCoordinator], SensorEntity):
|
|
"""Defines a Peblar sensor."""
|
|
|
|
entity_description: PeblarSensorDescription
|
|
|
|
@property
|
|
def native_value(self) -> datetime | int | str | None:
|
|
"""Return the state of the sensor."""
|
|
return self.entity_description.value_fn(self.coordinator.data)
|