HE60R Garage Door Opener
|
|
========================
|
|
|
|
.. seo::
|
|
:description: Setting up a Chamberlain HomEntry HE60R and similar garage door openers
|
|
:image: he60r.jpg
|
|
|
|
.. figure:: images/he60r.jpg
|
|
:align: right
|
|
|
|
The ``he60r`` cover platform allows you to control a HomEntry HE60R
|
|
garage door opener. These units were made by Chamberlain and sold through Bunnings. It is *likely* that this
|
|
component will also work with other older Chamberlain garage door openers. It is not currently compatible with
|
|
newer Chamberlain units that use the Security+ 2.0 protocol.
|
|
|
|
This component makes use of the HE60R keypad communication interface. This is a single-wire half duplex serial
|
|
connection and requires a :ref:`uart` component to be configured. The uart **must** be set to 1200 baud, EVEN parity. See
|
|
below for a sample hardware interface.
|
|
|
|
.. code-block:: yaml
|
|
|
|
# Example configuration entry
|
|
|
|
uart:
|
|
- id: door_uart
|
|
baud_rate: 1200
|
|
parity: even
|
|
stop_bits: 1
|
|
tx_pin: GPIOXX
|
|
rx_pin: GPIOXX
|
|
|
|
cover:
|
|
platform: he60r
|
|
id: garage_door
|
|
name: Garage Door
|
|
|
|
|
|
Configuration variables:
|
|
------------------------
|
|
|
|
- **open_duration** (*Optional*, :ref:`config-time`): The time required for the door to fully open from the closed position. Default 15s.
|
|
- **close_duration** (*Optional*, :ref:`config-time`): The time required for the door to fully close from the open position. Default 15s.
|
|
- All other options from :ref:`Cover <config-cover>`.
|
|
|
|
The open and close duration serve to estimate the position to provide feedback during travel and for partial open/close
|
|
requests. These can be adjusted according to your door's actual operation. Enabling DEBUG logging will report the
|
|
actual open and close times which will help to refine these timings.
|
|
|
|
Hardware Connection
|
|
-------------------
|
|
|
|
A sample circuit is shown below which also draws power from the HE60R - note that the 3.3V regulator must
|
|
be a switching type, a linear regulator would draw too much current and run hot. You can of course simply power
|
|
the ESP32 via USB from 5V. This circuit also includes a manual control button connected to a GPIO.
|
|
|
|
Any microcontroller board supported by ESPHome should be suitable for this application.
|
|
|
|
|
|
.. figure:: images/he60r-sch.jpg
|
|
:target: /_images/he60r-sch.jpg
|
|
|
|
|
|
Note that this circuit inverts the TX line. A configuration for this would look something like:
|
|
|
|
.. code-block:: yaml
|
|
|
|
# Example configuration entry
|
|
|
|
uart:
|
|
- id: door_uart
|
|
baud_rate: 1200
|
|
parity: even
|
|
stop_bits: 1
|
|
tx_pin:
|
|
number: GPIOXX
|
|
inverted: true
|
|
rx_pin: GPIOXX
|
|
|
|
cover:
|
|
platform: he60r
|
|
id: garage_door
|
|
name: Garage Door
|
|
|
|
binary_sensor:
|
|
- platform: gpio
|
|
pin:
|
|
number: GPIOXX
|
|
inverted: true
|
|
mode:
|
|
input: true
|
|
pullup: true
|
|
name: "Garage Door Manual Button"
|
|
# debounce the switch
|
|
filters:
|
|
- delayed_on: 50ms
|
|
- delayed_off: 50ms
|
|
on_press:
|
|
then:
|
|
- cover.toggle: garage_door
|
|
|
|
|
|
|
|
See Also
|
|
--------
|
|
|
|
- :doc:`index`
|
|
- :ref:`automation`
|
|
- :ref:`gpio-binary-sensor`
|
|
- :ghedit:`Edit`
|