The ``atm90e32`` sensor platform allows you to use your ATM90E32 voltage/current and power sensors
|
|
(`datasheet <http://ww1.microchip.com/downloads/en/devicedoc/Atmel-46003-SE-M90E32AS-Datasheet.pdf>`__) with
|
|
ESPHome. This sensor is commonly found in CircuitSetup 2 and 6 channel energy meters and the `Gelidus Research <https://www.gelidus.ca/>`__ 2 channel power meter.
|
|
|
|
Communication with the device is done via an :ref:`SPI bus <spi>`, so you need to have an ``spi:`` entry in your configuration
|
|
with both ``mosi_pin`` and ``miso_pin`` set.
|
|
|
|
The ATM90E32 IC can measure up to three AC voltages although typically only one
|
|
voltage measurement would be used for the mains electricity phase of a
|
|
household. Three current measurements are read via CT clamps.
|
|
|
|
The `CircuitSetup Split Single Phase Energy Meter <https://circuitsetup.us/index.php/product/split-single-phase-real-time-whole-house-energy-meter-v1-2/>`__ can read 2 current channels and 1 (expandable to 2) voltage channel.
|
|
|
|
.. figure:: images/atm90e32-cs-2chan-full.jpg
|
|
:align: center
|
|
:width: 50.0%
|
|
|
|
CircuitSetup Split Single Phase Real Time Whole House Energy Meter.
|
|
|
|
The `CircuitSetup 6-Channel Energy Monitor <https://circuitsetup.us/index.php/product/expandable-6-channel-esp32-energy-meter/>`__ can read 6 current channels and 2 voltage channels at a time, this board has two ATM90E32 ICs and requires two sensors to be configured in ESPHome.
|
|
|
|
.. figure:: images/atm90e32-cs-6chan-full.jpg
|
|
:align: center
|
|
:width: 50.0%
|
|
|
|
CircuitSetup Expandable 6 Channel ESP32 Energy Meter Main Board.
|
|
|
|
Configuration variables:
|
|
------------------------
|
|
|
|
- **cs_pin** (**Required**, :ref:`Pin Schema <config-pin_schema>`): The pin CS is connected to. For the 6 channel meter main board, this will always be 5 and 4. For the add-on boards a jumper can be selected for each CS pin, but default to 0 and 16.
|
|
- **line_frequency** (**Required**, string): The AC line frequency of the supply voltage. One of ``50Hz``, ``60Hz``.
|
|
- **phase_a** (*Optional*): The configuration options for the 1st phase.
|
|
|
|
- **voltage** (*Optional*): Use the voltage value of this phase in V (RMS).
|
|
All options from :ref:`Sensor <config-sensor>`.
|
|
- **current** (*Optional*): Use the current value of this phase in amperes. All options from
|
|
:ref:`Sensor <config-sensor>`.
|
|
- **power** (*Optional*): Use the power value on this phase in watts. All options from
|
|
:ref:`Sensor <config-sensor>`.
|
|
- **reactive_power** (*Optional*): Use the reactive power value on this phase. All options from
|
|
:ref:`Sensor <config-sensor>`.
|
|
- **power_factor** (*Optional*): Use the power factor value on this phase. All options from
|
|
:ref:`Sensor <config-sensor>`.
|
|
- **phase_angle** (*Optional*): Use the phase angle value on this phase in degrees. All options from
|
|
:ref:`Sensor <config-sensor>`.
|
|
- **peak_current** (*Optional*): Use the peak current value on this phase in amperes. All options from
|
|
:ref:`Sensor <config-sensor>`.
|
|
- **harmonic_power** (*Optional*): Use the harmonic power value on this phase. All options from
|
|
:ref:`Sensor <config-sensor>`.
|
|
- **gain_voltage** (*Optional*, int): Voltage gain to scale the low voltage AC power pack to household mains feed.
|
|
Defaults to ``7305``.
|
|
- **gain_ct** (*Optional*, int): CT clamp calibration for this phase.
|
|
Defaults to ``27961``.
|
|
- **forward_active_energy** (*Optional*): Use the forward active energy value on this phase in watt-hours.
|
|
All options from :ref:`Sensor <config-sensor>`.
|
|
- **reverse_active_energy** (*Optional*): Use the reverse active energy value on this phase in watt-hours.
|
|
All options from :ref:`Sensor <config-sensor>`.
|
|
|
|
- **phase_b** (*Optional*): The configuration options for the 2nd phase. Same options as 1st phase.
|
|
- **phase_c** (*Optional*): The configuration options for the 3rd phase. Same options as 1st phase.
|
|
- **frequency** (*Optional*): Use the frequency value calculated by the meter. All options from
|
|
:ref:`Sensor <config-sensor>`.
|
|
- **peak_current_signed** (*Optional*, boolean): Control the peak current output as signed or absolute. Defaults to ``false``.
|
|
- **chip_temperature** (*Optional*): Use the chip temperature value. All options from
|
|
:ref:`Sensor <config-sensor>`.
|
|
- **gain_pga** (*Optional*, string): The gain for the CT clamp, ``2X`` for 100A, ``4X`` for 100A - 200A. One of ``1X``, ``2X``, ``4X``.
|
|
Defaults to ``2X`` which is suitable for the popular SCT-013-000 clamp.
|
|
- **current_phases** (*Optional*): The number of phases the meter has, ``2`` or, ``3``
|
|
The 6 Channel Expandable Energy Meter should be set to ``3``, and the Split Single Phase meter should be set to ``2``. Defaults to ``3``.
|
|
- **update_interval** (*Optional*, :ref:`config-time`): The interval to check the sensor. Defaults to ``60s``.
|
|
- **spi_id** (*Optional*, :ref:`config-id`): Manually specify the ID of the :ref:`SPI Component <spi>` if you want
|
|
to use multiple SPI buses.
|
|
- **enable_offset_calibration** (*Optional*, boolean): If true it enables fine grained offset noise 0 level calibration for voltage and
|
|
current sensors. Buttons are required to operate the calibration feature. With multiple atm90e32 sensors each one is enabled
|
|
individually and it's buttons are mapped using an id value pair. e.g. ``id: chip1`` when more than one is defined. Offset calibration should only be used
|
|
when DC supply noise causes non 0 current or voltage readings. Calibration can only be performed when all voltage and current inputs are at a 0 value.
|
|
|
|
Button
|
|
------
|
|
|
|
.. code-block:: yaml
|
|
|
|
button:
|
|
- platform: atm90e32
|
|
id: chip1
|
|
run_offset_calibration:
|
|
name: "Chip1 - Run Offset Calibration"
|
|
clear_offset_calibration:
|
|
name: "Chip1 - Clear Offset Calibration"
|
|
|
|
Configuration variables:
|
|
|
|
- **id** (*Optional*, :ref:`config-id`): The ID of the atm90e32 defined above. Required if there are multiple atm90e32 configured.
|
|
- **run_offset_calibration** (*Optional*): A button to run the offset calibration.
|
|
All options from :ref:`Button <config-button>`.
|
|
- **clear_offset_calibration** (*Optional*): A button to clear the offset calibration.
|
|
All options from :ref:`Button <config-button>`.
|
|
|
|
Calibration
|
|
-----------
|
|
|
|
This sensor needs calibration to show correct values. The default gain configuration is set to use the
|
|
`SCT-013-000 <https://www.amazon.com/gp/product/B075541WVT>`__
|
|
current transformers, and the `Jameco Reliapro 9v AC transformer <https://www.amazon.com/gp/product/B00B886CWS>`__.
|
|
A load which uses a known amount of current can be used to calibrate. For for a more accurate calibration use a
|
|
`Kill-A-Watt <https://www.amazon.com/gp/product/B00009MDBU>`__ meter or similar, mains voltages can fluctuate depending on grid load.
|
|
|
|
Voltage
|
|
^^^^^^^
|
|
|
|
Use the expected mains voltage for your region 110V/230V or plug in the Kill-A-Watt and select voltage. See what
|
|
value the ATM90E32 sensor reports for voltage. To adjust the sensor use the calculation:
|
|
|
|
``New gain_voltage = (your voltage reading / ESPHome voltage reading) * existing gain_voltage value``
|
|
|
|
Update **gain_voltage** for all phases in your ESPHome yaml, recompile and upload. Repeat as necessary.
|
|
|
|
Here are common voltage calibrations for the **Split Single Energy Meter**:
|
|
For meter <= v1.3:
|
|
- 42080 - 9v AC Transformer - Jameco 112336
|
|
- 32428 - 12v AC Transformer - Jameco 167151
|
|
For meter > v1.4:
|
|
- 37106 - 9v AC Transformer - Jameco 157041
|
|
- 38302 - 9v AC Transformer - Jameco 112336
|
|
- 29462 - 12v AC Transformer - Jameco 167151
|
|
For Meters >= v1.4 rev.3
|
|
- 3920 - 9v AC Transformer - Jameco 157041
|
|
|
|
Here are common voltage calibrations for the **Expandable 6 Channel Energy Meter**:
|
|
For meter <= v1.2:
|
|
- 42080 - 9v AC Transformer - Jameco 112336
|
|
- 32428 - 12v AC Transformer - Jameco 167151
|
|
For meter > v1.3:
|
|
- 7305 - 9v AC Transformer - Jameco 157041
|
|
|
|
Current
|
|
^^^^^^^
|
|
|
|
Switch on the current load and see what value the ATM90E32 sensor reports for
|
|
current on the selected phase. Using the known or measured current adjust the
|
|
sensor using calculation:
|
|
|
|
``New gain_ct = (your current reading / ESPHome current reading) * existing gain_ct value``
|
|
|
|
Update **gain_ct** for the phase in your ESPHome yaml, recompile and upload. Repeat as necessary.
|
|
|
|
It is possible that the two identical CT current sensors will have different
|
|
**gain_ct** numbers due to variances in manufacturing, although it will be
|
|
small. The current calibration can be done once and used on all sensors or
|
|
repeated for each one.
|
|
|
|
Here are common current calibration values for the **Split Single Phase Energy Meter** when **gain_pga** is set to ``4X``:
|
|
- 200A/100mA SCT-024: 12597
|
|
|
|
Here are common current calibration values for the **Split Single Phase Energy Meter** when **gain_pga** is set to ``2X``:
|
|
- 20A/25mA SCT-006: 10170
|
|
- 100A/50mA SCT-013-000: 25498
|
|
- 120A/40mA SCT-016: 39473
|
|
- Magnalab 100A: 46539
|
|
|
|
Here are common current calibrations for the **Expandable 6 Channel Energy Meter** when **gain_pga** is set to ``1X``:
|
|
- 20A/25mA SCT-006: 11131
|
|
- 30A/1V SCT-013-030: 8650
|
|
- 50A/1V SCT-013-050: 15420
|
|
- 80A/26.6mA SCT-010: 41996 (note this will saturate at 2^16/10^3 amps)
|
|
- 100A/50ma SCT-013-000: 27961
|
|
- 120A/40mA: SCT-016: 41880
|
|
|
|
Active Energy
|
|
^^^^^^^^^^^^^
|
|
|
|
The ATM90E32 chip has a high-precision built-in ability to count the amount of consumed energy on a per-phase basis.
|
|
For each phase both the Forward and Reverse active energy is counted in watt-hours.
|
|
Forward Active Energy is used to count consumed energy, whereas Reverse Active Energy is used to count exported energy
|
|
(e.g. with solar PV installations).
|
|
The counters are reset every time a given active energy value is read from the ATM90E32 chip.
|
|
|
|
Current implementation targets users who retrieve the energy values with a regular interval and store them in
|
|
a time-series-database, e.g. InfluxDB.
|
|
|
|
**Example:**
|
|
|
|
.. code-block:: yaml
|
|
|
|
sensor:
|
|
#IC1 Main
|
|
- platform: atm90e32
|
|
cs_pin: GPIOXX
|
|
phase_a:
|
|
forward_active_energy:
|
|
name: ${disp_name} ct1 FAWattHours
|
|
id: ct1FAWattHours
|
|
state_topic: ${disp_name}/ct1/forward_active_energy
|
|
reverse_active_energy:
|
|
name: ${disp_name} ct1 RAWattHours
|
|
id: ct1RAWattHours
|
|
state_topic: ${disp_name}/ct1/reverse_active_energy
|
|
|
|
If the power, power_factor, reactive_power, forward_active_energy, or reverse_active_energy configuration variables
|
|
are used, care must be taken to ensure that the line ATM90E32's voltage is from is the same phase as the current
|
|
transformer is installed on. This is significant in split-phase or multi phase installations. On a house with 240
|
|
split-phase wiring (very common in the US), one simple test is to reverse the orientation of the current transformer
|
|
on a line. If the power factor doesn't change sign, it is likely that the voltage fed to the ATM90E32 is from the other
|
|
phase.
|
|
|
|
The CircuitSetup Expandable 6 channel board can easily handle this situation by cutting the jumpers JP12/13 to
|
|
allow a separate VA2 to be input on the J3 pads. Make sure that current taps connected to CT 1-3 are on the phase
|
|
from which VA is fed (the barrel jack) and the taps connected to CT3-6 are on the phase from which VA2 is fed. See
|
|
the CicuitSetup repo for more details on this.
|
|
|
|
If a multi board stack is being used, remember to cut JP12/13 on all boards and to feed VA2 to each board. VA is
|
|
fed to all boards through the stacking headers. Another detail is that each voltage transformer needs to have the
|
|
same polarity; getting this backwards will be just like having it on the wrong phase.
|
|
|
|
Note that the current measurement is the RMS value so is always positive. They only way to determine direction is to
|
|
look at the power factor. If there are only largely resistive loads and no power sources, (PF almost 1), it is simpler
|
|
to just create a template sensor that computes power from Irms*Vrms and ignore all these details. On the other
|
|
hand, one might be surprised how reactive some loads are and the CirciuitSetup designs are able to
|
|
handle these situations well.
|
|
|
|
Additional Examples
|
|
-------------------
|
|
|
|
.. code-block:: yaml
|
|
|
|
# Example configuration entry for split single phase meter
|
|
spi:
|
|
clk_pin: GPIOXX
|
|
miso_pin: GPIOXX
|
|
mosi_pin: GPIOXX
|
|
|
|
sensor:
|
|
- platform: atm90e32
|
|
cs_pin: GPIOXX
|
|
phase_a:
|
|
voltage:
|
|
name: "EMON Line Voltage A"
|
|
current:
|
|
name: "EMON CT1 Current"
|
|
power:
|
|
name: "EMON Active Power CT1"
|
|
reactive_power:
|
|
name: "EMON Reactive Power CT1"
|
|
power_factor:
|
|
name: "EMON Power Factor CT1"
|
|
gain_voltage: 3920
|
|
gain_ct: 39473
|
|
phase_c:
|
|
current:
|
|
name: "EMON CT2 Current"
|
|
power:
|
|
name: "EMON Active Power CT2"
|
|
reactive_power:
|
|
name: "EMON Reactive Power CT2"
|
|
power_factor:
|
|
name: "EMON Power Factor CT2"
|
|
gain_voltage: 3920
|
|
gain_ct: 39473
|
|
frequency:
|
|
name: "EMON Line Frequency"
|
|
chip_temperature:
|
|
name: "EMON Chip Temperature"
|
|
line_frequency: 50Hz
|
|
current_phases: 2
|
|
gain_pga: 2X
|
|
update_interval: 60s
|
|
|
|
.. code-block:: yaml
|
|
|
|
# Example CircuitSetup 6-channel entry
|
|
spi:
|
|
clk_pin: 18
|
|
miso_pin: 19
|
|
mosi_pin: 23
|
|
sensor:
|
|
- platform: atm90e32
|
|
cs_pin: 5
|
|
id: chip1 #Optional
|
|
phase_a:
|
|
voltage:
|
|
name: "EMON Line Voltage A"
|
|
current:
|
|
name: "EMON CT1 Current"
|
|
power:
|
|
name: "EMON Active Power CT1"
|
|
gain_voltage: 7305
|
|
gain_ct: 12577
|
|
phase_b:
|
|
current:
|
|
name: "EMON CT2 Current"
|
|
power:
|
|
name: "EMON Active Power CT2"
|
|
gain_voltage: 7305
|
|
gain_ct: 12577
|
|
phase_c:
|
|
current:
|
|
name: "EMON CT3 Current"
|
|
power:
|
|
name: "EMON Active Power CT3"
|
|
gain_voltage: 7305
|
|
gain_ct: 12577
|
|
frequency:
|
|
name: "EMON Line Frequency"
|
|
line_frequency: 50Hz
|
|
current_phases: 3
|
|
gain_pga: 1X
|
|
update_interval: 60s
|
|
enable_offset_calibration: True
|
|
- platform: atm90e32
|
|
cs_pin: 4
|
|
id: chip2 #Optional
|
|
phase_a:
|
|
current:
|
|
name: "EMON CT4 Current"
|
|
power:
|
|
name: "EMON Active Power CT4"
|
|
gain_voltage: 7305
|
|
gain_ct: 12577
|
|
phase_b:
|
|
current:
|
|
name: "EMON CT5 Current"
|
|
power:
|
|
name: "EMON Active Power CT5"
|
|
gain_voltage: 7305
|
|
gain_ct: 12577
|
|
phase_c:
|
|
current:
|
|
name: "EMON CT6 Current"
|
|
power:
|
|
name: "EMON Active Power CT6"
|
|
gain_voltage: 7305
|
|
gain_ct: 12577
|
|
line_frequency: 50Hz
|
|
current_phases: 3
|
|
gain_pga: 1X
|
|
update_interval: 60s
|
|
|
|
button:
|
|
- platform: atm90e32
|
|
id: chip1
|
|
run_offset_calibration:
|
|
name: "Chip1 - Run Offset Calibration"
|
|
clear_offset_calibration:
|
|
name: "Chip1 - Clear Offset Calibration"
|
|
|
|
|
|
.. code-block:: yaml
|
|
|
|
# Example CircuitSetup 6-channel without jumpers jp9-jp11 joined or < meter v1.4
|
|
# power is calculated in a template
|
|
|
|
substitutions:
|
|
disp_name: 6C
|
|
update_time: 10s
|
|
current_cal: '27961'
|
|
|
|
spi:
|
|
clk_pin: 18
|
|
miso_pin: 19
|
|
mosi_pin: 23
|
|
sensor:
|
|
- platform: atm90e32
|
|
cs_pin: 5
|
|
phase_a:
|
|
voltage:
|
|
name: ${disp_name} Volts A
|
|
id: ic1Volts
|
|
accuracy_decimals: 1
|
|
current:
|
|
name: ${disp_name} CT1 Amps
|
|
id: ct1Amps
|
|
gain_voltage: 7305
|
|
gain_ct: ${current_cal}
|
|
phase_b:
|
|
current:
|
|
name: ${disp_name} CT2 Amps
|
|
id: ct2Amps
|
|
gain_ct: ${current_cal}
|
|
phase_c:
|
|
current:
|
|
name: ${disp_name} CT3 Amps
|
|
id: ct3Amps
|
|
gain_ct: ${current_cal}
|
|
frequency:
|
|
name: ${disp_name} Freq A
|
|
line_frequency: 60Hz
|
|
current_phases: 3
|
|
gain_pga: 1X
|
|
update_interval: ${update_time}
|
|
- platform: atm90e32
|
|
cs_pin: 4
|
|
phase_a:
|
|
voltage:
|
|
name: ${disp_name} Volts B
|
|
id: ic2Volts
|
|
accuracy_decimals: 1
|
|
current:
|
|
name: ${disp_name} CT4 Amps
|
|
id: ct4Amps
|
|
gain_voltage: 7305
|
|
gain_ct: ${current_cal}
|
|
phase_b:
|
|
current:
|
|
name: ${disp_name} CT5 Amps
|
|
id: ct5Amps
|
|
gain_ct: ${current_cal}
|
|
phase_c:
|
|
current:
|
|
name: ${disp_name} CT6 Amps
|
|
id: ct6Amps
|
|
gain_ct: ${current_cal}
|
|
frequency:
|
|
name: ${disp_name} Freq B
|
|
line_frequency: 60Hz
|
|
current_phases: 3
|
|
gain_pga: 1X
|
|
update_interval: ${update_time}
|
|
|
|
#Watts per channel
|
|
- platform: template
|
|
name: ${disp_name} CT1 Watts
|
|
id: ct1Watts
|
|
lambda: return id(ct1Amps).state * id(ic1Volts).state;
|
|
accuracy_decimals: 0
|
|
unit_of_measurement: W
|
|
icon: "mdi:flash-circle"
|
|
update_interval: ${update_time}
|
|
- platform: template
|
|
name: ${disp_name} CT2 Watts
|
|
id: ct2Watts
|
|
lambda: return id(ct2Amps).state * id(ic1Volts).state;
|
|
accuracy_decimals: 0
|
|
unit_of_measurement: W
|
|
icon: "mdi:flash-circle"
|
|
update_interval: ${update_time}
|
|
- platform: template
|
|
name: ${disp_name} CT3 Watts
|
|
id: ct3Watts
|
|
lambda: return id(ct3Amps).state * id(ic1Volts).state;
|
|
accuracy_decimals: 0
|
|
unit_of_measurement: W
|
|
icon: "mdi:flash-circle"
|
|
update_interval: ${update_time}
|
|
- platform: template
|
|
name: ${disp_name} CT4 Watts
|
|
id: ct4Watts
|
|
lambda: return id(ct4Amps).state * id(ic2Volts).state;
|
|
accuracy_decimals: 0
|
|
unit_of_measurement: W
|
|
icon: "mdi:flash-circle"
|
|
update_interval: ${update_time}
|
|
- platform: template
|
|
name: ${disp_name} CT5 Watts
|
|
id: ct5Watts
|
|
lambda: return id(ct5Amps).state * id(ic2Volts).state;
|
|
accuracy_decimals: 0
|
|
unit_of_measurement: W
|
|
icon: "mdi:flash-circle"
|
|
update_interval: ${update_time}
|
|
- platform: template
|
|
name: ${disp_name} CT6 Watts
|
|
id: ct6Watts
|
|
lambda: return id(ct6Amps).state * id(ic2Volts).state;
|
|
accuracy_decimals: 0
|
|
unit_of_measurement: W
|
|
icon: "mdi:flash-circle"
|
|
update_interval: ${update_time}
|
|
#Total Amps
|
|
- platform: template
|
|
name: ${disp_name} Total Amps
|
|
id: totalAmps
|
|
lambda: return id(ct1Amps).state + id(ct2Amps).state + id(ct3Amps).state + id(ct4Amps).state + id(ct5Amps).state + id(ct6Amps).state ;
|
|
accuracy_decimals: 2
|
|
unit_of_measurement: A
|
|
icon: "mdi:flash"
|
|
update_interval: ${update_time}
|
|
#Total Watts
|
|
- platform: template
|
|
name: ${disp_name} Total Watts
|
|
id: totalWatts
|
|
lambda: return id(totalAmps).state * id(ic1Volts).state;
|
|
accuracy_decimals: 1
|
|
unit_of_measurement: W
|
|
icon: "mdi:flash-circle"
|
|
update_interval: ${update_time}
|
|
#kWh
|
|
- platform: total_daily_energy
|
|
name: ${disp_name} Total kWh
|
|
power_id: totalWatts
|
|
filters:
|
|
- multiply: 0.001
|
|
unit_of_measurement: kWh
|
|
|
|
Harmonic Power
|
|
--------------
|
|
|
|
Harmonic power in AC systems refers to deviations from the ideal sinusoidal waveform, caused by multiples of the
|
|
fundamental frequency. It results from non-linear loads and can lead to issues like voltage distortion, equipment
|
|
overheating, and miss operation of protective devices. The ATM90E32 can output advanced harmonic power measurements
|
|
providing important analysis data for monitoring power anomalies on the bus.
|
|
|
|
**Harmonic Power Example:**
|
|
|
|
.. code-block:: yaml
|
|
|
|
sensor:
|
|
- platform: atm90e32
|
|
phase_a:
|
|
harmonic_power:
|
|
name: ${disp_name} CT1 Harmonic Power
|
|
|
|
Phase Angle
|
|
-----------
|
|
|
|
Phase angle in AC systems represents the angular displacement of a sinusoidal waveform from a reference point.
|
|
It's a measure of timing difference between voltage and current. Phase angle is crucial for power factor assessment
|
|
and efficient power transfer. This advanced measurement function is available with an ATM90E32.
|
|
|
|
**Phase Angle Example:**
|
|
|
|
.. code-block:: yaml
|
|
|
|
sensor:
|
|
- platform: atm90e32
|
|
phase_a:
|
|
phase_angle:
|
|
name: ${disp_name} L1 Phase Angle
|
|
|
|
Peak Current
|
|
------------
|
|
|
|
Peak current in AC systems refers to the maximum value of the alternating current waveform. It signifies the highest
|
|
magnitude reached during each cycle of the sinusoidal waveform. Peak current is relevant for sizing components and
|
|
assessing the capacity of electrical equipment in the system. This advanced measurement is available from the ATM90E32.
|
|
Peak current can be displayed in signed or unsigned format using a boolean parameter which spans all phases.
|
|
The default is false which is unsigned.
|
|
|
|
**Peak Current Example:**
|
|
|
|
.. code-block:: yaml
|
|
|
|
sensor:
|
|
- platform: atm90e32
|
|
phase_a:
|
|
peak_current:
|
|
name: ${disp_name} CT1 Peak Current
|
|
peak_current_signed: True
|
|
|
|