64 lines
3.0 KiB
ReStructuredText
64 lines
3.0 KiB
ReStructuredText
Panasonic SN-GCJA5 Particulate Matter Sensor
|
|
============================================
|
|
|
|
.. seo::
|
|
:description: Instructions for setting up Panasonic SN-GCJA5 Particulate matter sensors
|
|
:image: gcja5.svg
|
|
|
|
The ``gcja5`` sensor platform allows you to use your Panasonic SN-GCJA5 laser based particulate matter sensor
|
|
(`datasheet <https://na.industrial.panasonic.com/products/sensors/air-quality-gas-flow-sensors/lineup/laser-type-pm-sensor/series/123557/model/123559>`__)
|
|
sensors with ESPHome.
|
|
|
|
As the communication with the GCJA5 is done using UART, you need
|
|
to have an :ref:`UART bus <uart>` in your configuration with the ``rx_pin`` connected to the SEND/TX. Additionally, you need to set the baud rate to 9600, and you
|
|
MUST have ``EVEN`` parity.
|
|
|
|
The sensor itself will push values every second. You may wish to :ref:`filter <sensor-filters>` this value to reduce the amount of data you are ingesting.
|
|
The sensor will internally track changes to the Laser Diode and Photo Diode over time to adjust and ensure accuracy.
|
|
Based on continous runtime, the sensor is rated to last at least 5 years.
|
|
|
|
.. code-block:: yaml
|
|
|
|
# Example configuration entry
|
|
|
|
sensor:
|
|
- platform: gcja5
|
|
pm_1_0:
|
|
name: "Particulate Matter <1.0µm Concentration"
|
|
pm_2_5:
|
|
name: "Particulate Matter <2.5µm Concentration"
|
|
pm_10_0:
|
|
name: "Particulate Matter <10.0µm Concentration"
|
|
|
|
Configuration variables:
|
|
------------------------
|
|
|
|
- **pm_1_0** (*Optional*): Mass of particles with a diameter of 1 micrometres or less (μg/m^3).
|
|
All options from :ref:`Sensor <config-sensor>`.
|
|
- **pm_2_5** (*Optional*): Mass of particles with a diameter of 2.5 micrometres or less (μg/m^3).
|
|
All options from :ref:`Sensor <config-sensor>`.
|
|
- **pm_10_0** (*Optional*): Mass of particles with a diameter of 10 micrometres or less (μg/m^3).
|
|
All options from :ref:`Sensor <config-sensor>`.
|
|
- **pm_10_0** (*Optional*): Mass of particles with a diameter of 10 micrometres or less (μg/m^3).
|
|
All options from :ref:`Sensor <config-sensor>`.
|
|
- **pmc_0_3** (*Optional*): Count of particles with diameter > 0.3 um in 0.1 L of air (#/0.1L).
|
|
All options from :ref:`Sensor <config-sensor>`.
|
|
- **pmc_0_5** (*Optional*): Count of particles with diameter > 0.5 um in 0.1 L of air (#/0.1L).
|
|
All options from :ref:`Sensor <config-sensor>`.
|
|
- **pmc_1_0** (*Optional*): Count of particles with diameter > 1 um in 0.1 L of air (#/0.1L).
|
|
All options from :ref:`Sensor <config-sensor>`.
|
|
- **pmc_2_5** (*Optional*): Count of particles with diameter > 2.5 um in 0.1 L of air (#/0.1L).
|
|
All options from :ref:`Sensor <config-sensor>`.
|
|
- **pmc_5_0** (*Optional*): Count of particles with diameter > 5 um in 0.1 L of air (#/0.1L).
|
|
All options from :ref:`Sensor <config-sensor>`.
|
|
- **pmc_10_0** (*Optional*): Count of particles with diameter > 10 um in 0.1 L of air (#/0.1L).
|
|
All options from :ref:`Sensor <config-sensor>`.
|
|
|
|
See Also
|
|
--------
|
|
|
|
- :doc:`/components/sensor/gcja5`
|
|
- :ref:`sensor-filters`
|
|
- :apiref:`gcja5/gcja5.h`
|
|
- :ghedit:`Edit`
|