.. seo::
:description: Instructions for setting up a Growatt inverter reading on modbus.
:image: growatt.jpg
:keywords: Growatt, Ginverter
The ``Growatt Inverter`` sensor platform allows you to use growatt inverter data reading on modbus with ESPHome.
.. figure:: images/growatt.jpg
:align: center
:width: 50.0%
Growatt Logo
The communication with this component is done over a :ref:`UART bus <uart>` using :ref:`Modbus <modbus>`.
You must therefore have a ``uart:`` and ``modbus:`` entry in your configuration with both the TX and RX pins set
to some pins on your board and the baud rate set to 9600.
.. code-block:: yaml
# Example configuration
sensor:
- platform: growatt_solar
protocol_version: RTU
inverter_status:
name: "Growatt Status Code"
phase_a:
voltage:
name: "Growatt Voltage Phase A"
current:
name: "Growatt Current Phase A"
active_power:
name: "Growatt Power Phase A"
phase_b:
voltage:
name: "Growatt Voltage Phase B"
current:
name: "Growatt Current Phase B"
active_power:
name: "Growatt Power Phase B"
phase_c:
voltage:
name: "Growatt Voltage Phase C"
current:
name: "Growatt Current Phase C"
active_power:
name: "Growatt Power Phase C"
pv1:
voltage:
name: "Growatt PV1 Voltage"
current:
name: "Growatt PV1 Current"
active_power:
name: "Growatt PV1 Active Power"
pv2:
voltage:
name: "Growatt PV2 Voltage"
current:
name: "Growatt PV2 Current"
active_power:
name: "Growatt PV2 Active Power"
active_power:
name: "Growatt Grid Active Power"
pv_active_power:
name: "Growatt PV Active Power"
frequency:
name: "Growatt Frequency"
energy_production_day:
name: "Growatt Today's Generation"
total_energy_production:
name: "Growatt Total Energy Production"
inverter_module_temp:
name: "Growatt Inverter Module Temp"
Configuration variables:
------------------------
- **inverter_status** (*Optional*): Status code of the inverter (0: waiting, 1: normal, 3:fault)
- **protocol_version** (*Optional*): Version of the protocol used by your inverter.
Old inverters use RTU (default). Newer ones use RTU2 (e.g. MIC, MIN, MAX series)
- **phase_a** (*Optional*): The group of exposed sensors for Phase A/1.
- **current** (*Optional*): Use the current value of the sensor in amperes. All options from
:ref:`Sensor <config-sensor>`.
- **voltage** (*Optional*): Use the voltage value of the sensor in volts.
All options from :ref:`Sensor <config-sensor>`.
- **active_power** (*Optional*): Use the (active) power value of the sensor in watts. All options
from :ref:`Sensor <config-sensor>`.
- **phase_b** (*Optional*): The group of exposed sensors for Phase B/2 on applicable inverters.
- All options from **phase_a**
- **phase_c** (*Optional*): The group of exposed sensors for Phase C/3 on applicable inverters.
- All options from **phase_a**
- **pv1** (*Optional*): The group of exposed sensors for Photo Voltaic 1.
- **current** (*Optional*): Use the current value of the sensor in amperes. All options from
:ref:`Sensor <config-sensor>`.
- **voltage** (*Optional*): Use the voltage value of the sensor in volts.
All options from :ref:`Sensor <config-sensor>`.
- **active_power** (*Optional*): Use the (active) power value of the sensor in watts. All options
from :ref:`Sensor <config-sensor>`.
- **pv2** (*Optional*): The group of exposed sensors for Photo Voltaic 2.
- All options from **pv1**
- **active_power** (*Optional*): Use the (active) power value for the Grid in watts. All options
from :ref:`Sensor <config-sensor>`.
- **pv_active_power** (*Optional*): Use the (active) power value of PVs in total in watts. All options
from :ref:`Sensor <config-sensor>`.
- **frequency** (*Optional*): Use the frequency value of the sensor in hertz.
All options from :ref:`Sensor <config-sensor>`.
- **energy_production_day** (*Optional*): Use the export active energy value for same day of the
sensor in kilo watt hours. All options from :ref:`Sensor <config-sensor>`.
- **total_energy_production** (*Optional*): Use the total exported energy value of the sensor in
kilo watt hours. All options from :ref:`Sensor <config-sensor>`.
- **inverter_module_temp** (*Optional*): Use the inverter module temperature value of the sensor in
degree celsius. All options from :ref:`Sensor <config-sensor>`.
- **update_interval** (*Optional*, :ref:`config-time`): The interval to check the
sensor. Defaults to ``10s``.
- **address** (*Optional*, int): The address of the sensor if multiple sensors are attached to
the same UART bus. You will need to set the address of each device manually. Defaults to ``1``.