HTE501 Temperature+Humidity Sensor
|
|
===================================
|
|
|
|
.. seo::
|
|
:description: Instructions for setting up HTE501 temperature and humidity sensors
|
|
:image: HTE501.png
|
|
|
|
The ``hte501`` sensor platform Temperature+Humidity sensor allows you to use your HTE501
|
|
(`datasheet <https://www.epluse.com/fileadmin/data/product/hte501/datasheet_HTE501.pdf>`__ ,
|
|
`E+E HTE501 <https://www.epluse.com/products/humidity-instruments/humidity-sensing-elements/hte501/>`__) sensor with
|
|
ESPHome. The :ref:`I²C Bus <i2c>` is
|
|
required to be set up in your configuration for this sensor to work.
|
|
|
|
|
|
.. figure:: images/HTE501.png
|
|
:align: center
|
|
:width: 80.0%
|
|
|
|
.. code-block:: yaml
|
|
|
|
# Example configuration entry
|
|
sensor:
|
|
- platform: hte501
|
|
temperature:
|
|
name: "Office Temperature"
|
|
humidity:
|
|
name: "Office Humidity"
|
|
address: 0x40
|
|
update_interval: 60s
|
|
|
|
Configuration variables:
|
|
------------------------
|
|
|
|
- **temperature** (**Required**): The information for the temperature sensor.
|
|
|
|
- All options from :ref:`Sensor <config-sensor>`.
|
|
|
|
- **humidity** (**Required**): The information for the humidity sensor.
|
|
|
|
- All options from :ref:`Sensor <config-sensor>`.
|
|
|
|
- **address** (*Optional*, int): Manually specify the I²C address of the sensor.
|
|
Defaults to ``0x40``.
|
|
- **update_interval** (*Optional*, :ref:`config-time`): The interval to check the
|
|
sensor. Defaults to ``60s``.
|
|
|
|
See Also
|
|
--------
|
|
|
|
- :ref:`sensor-filters`
|
|
- :doc:`absolute_humidity`
|
|
- :doc:`tee501`
|
|
- :doc:`ee895`
|
|
- :doc:`dht`
|
|
- :doc:`dht12`
|
|
- :apiref:`hte501/hte501.h`
|
|