52 lines
1.6 KiB
ReStructuredText
52 lines
1.6 KiB
ReStructuredText
AMS iAQ-Core Indoor Air Quality Sensor
|
|
======================================
|
|
|
|
.. seo::
|
|
:description: Instructions for setting up the iAQ-Core sensor.
|
|
:image: iaqcore.jpg
|
|
:keywords: co2, tvoc, i2c
|
|
|
|
The AMS iAQ-Core sensor allows you to use your
|
|
(`datasheet <https://www.sciosense.com/wp-content/uploads/documents/iaQ-Core-Datasheet.pdf>`__)
|
|
sensors with ESPHome.
|
|
|
|
.. figure:: images/iaqcore.jpg
|
|
:align: center
|
|
:width: 30.0%
|
|
|
|
AMS iAQ-Core Indoor Air Quality Sensor.
|
|
|
|
The iAQ-Core sensor module is used to measure VOC levels and provide CO2 equivalent and TVOC equivalent predictions. The data is available via I²C bus.
|
|
|
|
To use the sensor, first set up an :ref:`I²C Bus <i2c>` and connect the sensor to the specified pins.
|
|
|
|
.. code-block:: yaml
|
|
|
|
# Example configuration entry
|
|
sensor:
|
|
- platform: iaqcore
|
|
address: 0x5A
|
|
update_interval: 60s
|
|
co2:
|
|
name: "iAQ Core CO2 Sensor"
|
|
tvoc:
|
|
name: "iAQ Core TVOC Sensor"
|
|
|
|
Configuration variables:
|
|
------------------------
|
|
|
|
- **i2c_id** (*Optional*, ID): The id of the I²C Bus.
|
|
- **address** (*Optional*, int): Manually specifiy the I²C address of the sensor. Defaults to ``0x5A``.
|
|
- **update_interval** (*Optional*, :ref:`config-time`): The interval to check the sensor. Defaults to ``60s``.
|
|
- **co2** (*Optional*): The configuration for the CO2 sensor. All options from
|
|
:ref:`Sensor <config-sensor>`.
|
|
- **tvoc** (*Optional*): The configuration for the TVOC sensor. All options from
|
|
:ref:`Sensor <config-sensor>`.
|
|
|
|
See Also
|
|
--------
|
|
|
|
- :ref:`sensor-filters`
|
|
- :doc:`/components/sensor/index`
|
|
- :ghedit:`Edit`
|