102 lines
2.7 KiB
ReStructuredText
102 lines
2.7 KiB
ReStructuredText
Radon Eye BLE Sensors
|
|
=====================
|
|
|
|
.. seo::
|
|
:description: Instructions for setting up Radon Eye bluetooth-based sensors in ESPHome.
|
|
:keywords: Radon, RadonEye, RD200, BLE, Bluetooth, Wave Plus, Wave Mini
|
|
|
|
The ``radon_eye_rd200`` sensor platforms lets you track the output of Radon Eye RD200 Bluetooth Low Energy device.
|
|
|
|
This component will track radon concentration.
|
|
|
|
Device Discovery
|
|
-----------------
|
|
|
|
RadonEye devices can be found using the ``radon_eye_ble`` ble scanner.
|
|
|
|
To find out your device's MAC address, add the following to your ESPHome configuration:
|
|
|
|
.. code-block:: yaml
|
|
|
|
logger:
|
|
level: DEBUG # Required for the tracker to show the device
|
|
|
|
esp32_ble_tracker:
|
|
radon_eye_ble:
|
|
|
|
The device will then listen for nearby devices, and display a message like this one:
|
|
|
|
.. code-block:: text
|
|
|
|
[D][radon_eye_ble:017]:
|
|
Found Radon Eye RD200 device Name: FR:R20:SN1234 (MAC: XX:XX:XX:XX:XX:XX)
|
|
|
|
Once the device is found, remove the ``radon_eye_ble`` device tracker from your configuration and
|
|
take note of the device MAC address, and use it when configuring a sensor below.
|
|
|
|
Supported Devices
|
|
-----------------
|
|
|
|
Radon Eye RD200 Sensor
|
|
**********************
|
|
|
|
Radon Eye RD200 tracks radon concentration over short periods (5 min interval) and longer periods
|
|
(24h or month).
|
|
|
|
The ``radon_long_term`` sensor is populated with the longest available measurement. The RD200
|
|
provides a 24hr measurement and a 1 month measurement.
|
|
|
|
If the 1 month isn't available, it will use
|
|
the 24hr. If the 24hr isn't available either, it will not publish the value.
|
|
|
|
.. figure:: images/radon_eye_rd200.jpg
|
|
:align: center
|
|
:width: 60.0%
|
|
|
|
Configuration example:
|
|
**********************
|
|
|
|
.. code-block:: yaml
|
|
|
|
esp32_ble_tracker:
|
|
|
|
ble_client:
|
|
- mac_address: XX:XX:XX:XX:XX:XX
|
|
id: radon_eye_ble_id
|
|
|
|
sensor:
|
|
- platform: radon_eye_rd200
|
|
ble_client_id: radon_eye_ble_id
|
|
update_interval: 5min # default
|
|
radon:
|
|
name: "Radon"
|
|
radon_long_term:
|
|
name: "Radon Long Term"
|
|
|
|
Here is an example to use pCi/L (to match the value on the device display):
|
|
|
|
.. code-block:: yaml
|
|
|
|
esp32_ble_tracker:
|
|
|
|
ble_client:
|
|
- mac_address: XX:XX:XX:XX:XX:XX
|
|
id: radon_eye_ble_id
|
|
|
|
sensor:
|
|
- platform: radon_eye_rd200
|
|
ble_client_id: radon_eye_ble_id
|
|
update_interval: 5min # default
|
|
radon:
|
|
name: "Radon"
|
|
unit_of_measurement: "pCi/L"
|
|
accuracy_decimals: 2
|
|
filters:
|
|
- lambda: return x / 37;
|
|
radon_long_term:
|
|
name: "Radon Long Term"
|
|
unit_of_measurement: "pCi/L"
|
|
accuracy_decimals: 2
|
|
filters:
|
|
- lambda: return x / 37;
|