T6613/15 CO2 Sensors
|
|
==================================
|
|
|
|
.. seo::
|
|
:description: Instructions for setting up T6613 and T6615 sensors for ESPHome
|
|
:image: t6615.jpg
|
|
:keywords: t6613 t6615
|
|
|
|
The ``t6615`` sensor platform allows you to use T6613 and T6615 family sensors
|
|
(`amphenol`_) with ESPHome. T6613 sensors are unreferenced and require ABC to
|
|
calibrate daily, while the T6615 sensors have a sealed reference gas and
|
|
do not require ABC calibration. All ppm ranges are supported by this platform.
|
|
|
|
.. figure:: images/t6615.png
|
|
:align: center
|
|
:width: 50.0%
|
|
|
|
T6615 CO_2 Sensor.
|
|
|
|
.. _amphenol: https://amphenol-sensors.com/en/telaire/co2/525-co2-sensor-modules/319-t6615
|
|
|
|
As the communication is done using UART, you need to have an :ref:`UART bus <uart>` in your configuration with the
|
|
``rx_pin`` connected to the TX pin of the device (pin 10) and the ``tx_pin`` connected to the RX Pin of the device (pin
|
|
11). The baud rate should be set to 19200.
|
|
|
|
Additionally, the T6613/15 sensors require 5V power, while most ESP platforms only output 3.3V from their onboard
|
|
regulator, so you may need some additional components to power up the sensor.
|
|
|
|
.. code-block:: yaml
|
|
|
|
# Example configuration entry
|
|
sensor:
|
|
- platform: t6615
|
|
co2:
|
|
name: CO2
|
|
|
|
Configuration variables:
|
|
------------------------
|
|
|
|
|
|
- **co2** (**Required**): The CO_2 data from the sensor in parts per million (ppm).
|
|
All options from :ref:`Sensor <config-sensor>`.
|
|
|
|
- **update_interval** (*Optional*, :ref:`config-time`): The interval to check the
|
|
sensor. Defaults to ``60s``.
|
|
|
|
- **uart_id** (*Optional*, :ref:`config-id`): Manually specify the ID of the :ref:`UART Component <uart>` if you want
|
|
to use multiple UART buses.
|
|
|
|
- **id** (*Optional*, :ref:`config-id`): Manually specify the ID used for actions.
|
|
|
|
.. figure:: images/t6615-pins.png
|
|
:align: center
|
|
:width: 80.0%
|
|
|
|
Pins on the T6615. Only the ones marked with a red circle need to be connected.
|
|
|
|
|
|
See Also
|
|
--------
|
|
|
|
- :ref:`sensor-filters`
|
|
- `UART Protocol Documentation <https://amphenol-sensors.com/en/component/edocman/561-telaire-co2-sensors-uart-communications-protocol/download?Itemid=8486%20%27>`__
|
|
- :apiref:`t6615/t6615.h`
|
|