TE-M3200 Pressure Sensor
|
|
===========================================
|
|
|
|
.. seo::
|
|
:description: Instructions for setting up TE-M3200 pressure sensors with ESPHome
|
|
:image: tem3200.jpg
|
|
:keywords: TEM3200 TE-M3200
|
|
|
|
The ``tem3200`` sensor platform allows you to use your TE-M3200 (`datasheet <https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Data+Sheet%7FM3200%7FA20%7Fpdf%7FEnglish%7FENG_DS_M3200_A20.pdf>`__,
|
|
`product page <https://www.te.com/en/product-CAT-PTT0068.html>`__) pressure sensors with ESPHome.
|
|
|
|
.. figure:: images/tem3200.jpg
|
|
:align: center
|
|
:width: 50.0%
|
|
|
|
TE-M3200 Pressure Sensor.
|
|
|
|
|
|
Configuration
|
|
-------------
|
|
:ref:`I²C <i2c>` bus is required to be set up in your configuration for this sensor to work.
|
|
|
|
.. code-block:: yaml
|
|
|
|
# Example configuration entry
|
|
sensor:
|
|
- platform: tem3200
|
|
raw_pressure:
|
|
name: "Raw Pressure"
|
|
temperature:
|
|
name: Temperature
|
|
|
|
|
|
Configuration variables
|
|
-----------------------
|
|
|
|
- **raw_pressure** (*Optional*): The information for the pressure sensor. See :ref:`tem3200-converting`.
|
|
|
|
- All other options from :ref:`Sensor <config-sensor>`.
|
|
|
|
- **temperature** (*Optional*): The information for the temperature sensor. Readings in degrees celsius (°C).
|
|
|
|
- All other options from :ref:`Sensor <config-sensor>`.
|
|
|
|
- **i2c_id** (*Optional*, :ref:`config-id`): Manually specify the ID of the :ref:`I²C Component <i2c>`. Defaults to the default I²C bus.
|
|
|
|
- **address** (*Optional*, int): Manually specify the I²C address of the sensor. Defaults to ``0x28``. See `datasheet
|
|
<https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Data+Sheet%7FM3200%7FA20%7Fpdf%7FEnglish%7FENG_DS_M3200_A20.pdf>`__
|
|
(page 10).
|
|
|
|
|
|
.. _tem3200-converting:
|
|
|
|
Converting units
|
|
-----------------
|
|
|
|
The TE-M3200 pressure sensor is not calibrated to units, you have to convert the measurement to units yourself.
|
|
|
|
Estimated
|
|
*********
|
|
|
|
On page 6 of the `datasheet <https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Data+Sheet%7FM3200%7FA20%7Fpdf%7FEnglish%7FENG_DS_M3200_A20.pdf>`__
|
|
the value ``1000`` maps to approximately ``0%`` of the maximum value of the sensor (e.g. ``0`` psi for a ``100`` psi sensor);
|
|
the value ``8000`` maps to approximately ``50%`` of the maximum value of the sensor (e.g. ``50`` psi for a ``100`` psi sensor);
|
|
the value ``15000`` maps to approximately ``100%`` of the maximum value of the sensor (e.g. ``100`` psi for the ``100`` psi sensor).
|
|
Use ``calibrate_linear`` filter to map these sensor values:
|
|
|
|
.. code-block:: yaml
|
|
|
|
# Extract of configuration
|
|
filters:
|
|
- calibrate_linear:
|
|
- 1000 -> 0.0
|
|
- 8000 -> 50.0
|
|
- 15000 -> 100.0
|
|
|
|
Calibrated
|
|
**********
|
|
1. Expose the sensor to a low known pressure, for example ``5`` psi.
|
|
2. Observe the value of the raw pressure sensor, for example ``990``.
|
|
3. Expose the sensor to a high pressure, for example ``90`` psi.
|
|
4. Observe the value of the raw pressure sensor, for example ``13550``.
|
|
5. Use ``calibrate_linear`` filter to map the incoming value to the calibrated one:
|
|
|
|
.. code-block:: yaml
|
|
|
|
# Extract of configuration
|
|
filters:
|
|
- calibrate_linear:
|
|
- 990 -> 5.0
|
|
- 13550 -> 90.0
|
|
|
|
|
|
See Also
|
|
--------
|
|
|
|
- :ref:`sensor-filters`
|
|
- `TE-M3200 Product Page <https://www.te.com/en/product-CAT-PTT0068.html>`__
|
|