CFSensor XGZP68xx Series Differential Pressure Sensor
|
|
=====================================================
|
|
|
|
.. seo::
|
|
:description: Instructions for setting up the CFSensor XGZP68xx Series Differential Pressure sensor.
|
|
:image: 6897d.jpg
|
|
:keywords: XGZP68xx, XGZP6897, XGZP6899, XGZP6899D, XGZP6897D
|
|
|
|
The XGZP68xx Differential Pressure sensor allows you to use digital differential pressure sensors such as the 6899D
|
|
(`datasheet <https://cfsensor.com/wp-content/uploads/2022/11/XGZP6899D-Pressure-Sensor-V2.8.pdf>`__) or
|
|
6897D Series (`datasheet <https://cfsensor.com/wp-content/uploads/2022/11/XGZP6897D-Pressure-Sensor-V2.7.pdf>`__)
|
|
sensors with ESPHome. The sensors pressure ranges are specified in the datasheets.
|
|
|
|
Calibrating the sensor can be done by checking the value that is returned when
|
|
the ports are open to the air. This value should be 0. If it is not, you can use the offset option to correct the
|
|
reading. For example, if your sensor is reading -40Pa when the ports are disconnected, you can set the offset to 40.
|
|
|
|
.. figure:: images/6897d.jpg
|
|
:align: center
|
|
:width: 30.0%
|
|
|
|
XGZP6897D Differential Pressure Sensor.
|
|
(Credit: `CFSensor <https://cfsensor.net/i2c-differential-pressure-sensor-xgzp6897d/>`__, image cropped and compressed)
|
|
|
|
.. _Sparkfun: https://www.sparkfun.com/products/17874
|
|
|
|
To use the sensor, set up an :ref:`I²C Bus <i2c>` and connect the sensor to the specified pins.
|
|
|
|
.. code-block:: yaml
|
|
|
|
# Example configuration entry
|
|
# It uses a filter offset to calibrate the sensor
|
|
sensor:
|
|
- platform: xgzp68xx
|
|
temperature:
|
|
name: "Temperature"
|
|
pressure:
|
|
name: "Differential Pressure"
|
|
filters:
|
|
- offset: 40.5
|
|
|
|
Configuration variables:
|
|
------------------------
|
|
|
|
- **temperature** (*Optional*): All options from :ref:`Sensor <config-sensor>`.
|
|
- **pressure** (*Optional*): All options from :ref:`Sensor <config-sensor>`.
|
|
- **k_value** (*Optional*, int): The K value comes from the datasheet. It will default to 4096 if not specified, which is appropriate for a sensor with a range of +/- 0.5kPa.
|
|
- **update_interval** (*Optional*, :ref:`config-time`): The interval to check the sensor. Defaults to ``60s``.
|
|
|
|
|
|
See Also
|
|
--------
|
|
- `esphome-pressure device <https://github.com/gcormier/esphome-pressure/>`__
|
|
- :ref:`sensor-filters`
|
|
- :apiref:`sdp3x/sdp3x.h`
|
|
- :ghedit:`Edit`
|