esphome/tests/components/selec_meter/test.esp8266-ard.yaml

46 lines
1.3 KiB
YAML

uart:
- id: uart_selec_meter
tx_pin: 4
rx_pin: 5
baud_rate: 9600
sensor:
- platform: selec_meter
total_active_energy:
name: SelecEM2M Total Active Energy
import_active_energy:
name: SelecEM2M Import Active Energy
export_active_energy:
name: SelecEM2M Export Active Energy
total_reactive_energy:
name: SelecEM2M Total Reactive Energy
import_reactive_energy:
name: SelecEM2M Import Reactive Energy
export_reactive_energy:
name: SelecEM2M Export Reactive Energy
apparent_energy:
name: SelecEM2M Apparent Energy
active_power:
name: SelecEM2M Active Power
reactive_power:
name: SelecEM2M Reactive Power
apparent_power:
name: SelecEM2M Apparent Power
voltage:
name: SelecEM2M Voltage
current:
name: SelecEM2M Current
power_factor:
name: SelecEM2M Power Factor
frequency:
name: SelecEM2M Frequency
maximum_demand_active_power:
name: SelecEM2M Maximum Demand Active Power
disabled_by_default: true
maximum_demand_reactive_power:
name: SelecEM2M Maximum Demand Reactive Power
disabled_by_default: true
maximum_demand_apparent_power:
name: SelecEM2M Maximum Demand Apparent Power
disabled_by_default: true