<CommandClass id="112">
<Value type="byte" genre="config" instance="1" index="1" label="Set to Default" value="-1">
<Help>Set all configuration values to default values (factory settings).</Help>
</Value>
<Value type="list" genre="config" instance="1" index="2" label="Button Type" value="0" size="1">
<Help>The way how the button reacts when press/released</Help>
<Item label="Toggle light when button is pressed, no action when button is released." value="0"/>
<Item label="Toggle light when button is released, Start dimming when button pressed." value="1"/>
<Item label="Toggle light when button is pressed and when button is Released, start dimming when quickly press and release button." value="2"/>
</Value>
<Value type="list" genre="config" instance="1" index="3" label="Control Type" value="0" size="1">
<Help>The way the Built-in Dimmer reacts when light is turned on/off with button</Help>
<Item label="Switch own light on and send a Z-Wave message to all associated nodes (direct and extern)" value="0"/>
<Item label="Don.t switch own light on but only send a Z-Wave message to associated node. (extern only)" value="1"/>
</Value>
<Value type="byte" genre="config" instance="1" index="4" label="Dimming enabled" value="1">
<Help>This parameter is used to enable the dimming option of the product. When disabled the dimming and fading routine are disabled.</Help>
<Item label="Dimming disabled." value="0"/>
<Item label="Dimming enabled." value="2"/>
</Value>
<Value type="short" genre="config" instance="1" index="6" label="Maximum Powerload" value="200" size="2">
<Help>The maximum powerload in watts when light is turned on, when measured higher then this value the Inline Dimmer is automatically turned off.</Help>
</Value>
<Value type="byte" genre="config" instance="1" index="7" label="Dimming Speed" value="3">
<Help>The speed of dimming when activated (manual and RF). Dim speed is 1% per value (* 10 ms)</Help>
</Value>
<Value type="byte" genre="config" instance="1" index="8" label="Fading up Speed" value="3">
<Help>The speed of fading up when activated (manual and RF). Fade speed is 1% per value (* 10 ms)</Help>
</Value>
<Value type="byte" genre="config" instance="1" index="9" label="Toggle time" value="50">
<Help>The time window to repress button to start dimming. Toggle time is value (* 10ms)</Help>
</Value>
<Value type="byte" genre="config" instance="1" index="11" label="Auto meter report: percentage" value="20">
<Help>A percentage that an energy value must be different compared to a previous sent value before an unsolicited meter report is sent. Minimum value = 10% Maximum value = 100%</Help>
</Value>
<Value type="byte" genre="config" instance="1" index="12" label="Auto meter report: watt" value="10">
<Help>A watt value that an energy value must be different compared to a previous sent value before an unsolicited meter report is sent. Minimum value = 5 watt Maximum value = 255 watt</Help>
</Value>
<Value type="byte" genre="config" instance="1" index="13" label="Auto meter report: time" value="20">
<Help>A time value that has to be passed compared to a previous sent value before a unsolicited meter report is sent. Minimum value = 10 seconds Maximum value = 255 seconds</Help>
</Value>
<Value type="byte" genre="config" instance="1" index="14" label="Last known status" value="0">
<Help>What to do with lamp status when power applied. If 0x00: Always switch light off when power applied. If > 0x00: Switch lamp on/off depending on last known lampstatus before power was disconnected.</Help>
</Value>
<Value type="byte" genre="config" instance="1" index="15" label="Fading down speed" value="1">
<Help>The speed of fading up when activated (manual and RF). Fade speed is 1% per value (* 10 ms)</Help>
</Value>
</CommandClass>
<!-- Association Groups -->
<CommandClass id="133">
<Associations num_groups="3">
<Group index="1" max_associations="8" label="Group 1: All nodes in this group will receive a BASIC_SET frame when light is set to a certain state with the button of the Built-in Dimmer (manual switching)." auto="false"/>
<Group index="2" max_associations="1" label="Group 2: The node associated in this group will receive a SWITCH_MULTILEVEL_REPORT frame every time the level of light is changed, where the value represents the (changed) dim level. The status is reported after every change that means manual but also if changed by Z-Wave. The node in this group will also received the (auto) METER_REPORT." auto="true"/>
<Group index="3" max_associations="1" label="Group 3: If configured that the control mode is extern only (configuration param3, value 1) then a BASIC_SET frame is sent to the node in this group when the button is changed."/>
</Associations>