<CommandClass id="64" name="COMMAND_CLASS_THERMOSTAT_MODE">
<Value type="list" genre="user" instance="1" index="0" label="Mode" units="" read_only="false" write_only="false" min="0" max="0" value="0">
<Item label="Heat" value="1"/>
<Item label="Energy Heat" value="11"/>
</Value>
<SupportedModes>
<Mode index="1" label="Heat"/>
<Mode index="11" label="Energy Heat"/>
</SupportedModes>
</CommandClass>
<CommandClass id="67" name="COMMAND_CLASS_THERMOSTAT_SETPOINT" version="1" request_flags="4" create_vars="true" base="0">
<Instance index="1"/>
<Value type="decimal" genre="user" instance="1" index="1" label="Heating" units="C" read_only="false" write_only="false" min="0" max="0" value="20"/>
<Value type="decimal" genre="user" instance="1" index="11" label="Energy Heat" units="C" read_only="false" write_only="false" min="0" max="0" value="16"/>
</CommandClass>
<!-- Configuration -->
<CommandClass id="112">
<Value type="byte" genre="config" instance="1" index="1" label="Reset to Default" size="1" value="0">
<Help>0xFF: Set all configuration values to default values (factory settings).
CONFIGURATION_REPORT
0x55: Configuration settings of the device are altered.
0xAA: Configuration of the device is untouched.
Note that this value will not change to 0x55 upon modifying the wake up interval and that re-setting the value to 0xAA will always reset the wake up interval.
</Help>
</Value>
<Value type="byte" genre="config" instance="1" index="2" label="Data request interval" value="20" size="1">
<Help>The interval that data is requested (and therefore updated) from the thermostat and boiler. Value in seconds. </Help>
</Value>
<Value type="byte" genre="config" instance="1" index="3" label="T room update difference" value="1" size="1">
<Help>The value that the room temperature must differ (compared to his previous send value) before an unsolicited room temperature report is send to the associated node. Value in 0.1C. </Help>
</Value>
<Value type="byte" genre="config" instance="1" index="4" label="T setpoint update difference" value="5" size="1">
<Help>The value that the temperature setpoint must differ (compared to his previous send value) before an unsolicited temperature setpoint report is send to the associated node. Value in 0.1C .</Help>
</Value>
<Value type="list" genre="config" instance="1" index="5" label="Unsolicited CRC" size="1" value="1">
<Help>TConfigure if the unsolicited reports are send with the CRC-16 encapsulation. Not that the receiving node should support this encapsulation to parse the Z-Wave frame!</Help>
<Item label="Disabled" value="0"/>
<Item label="Enabled" value="255"/>
</Value>
<Value type="list" genre="config" instance="1" index="6" label="Type of 'special' thermostat" size="1" value="0">
<Help>Type of 'special' thermostat: NOTE: when remeha Celcia 20 support is set then any other thermostat can not be set (!) NOTE2: when Remeha Celcia 20 gives 'Fout 203' send cfg value again</Help>
<Item label="No special" value="0"/>
<Item label="Remeha Celcia 20" value="1"/>
<Item label="Honeywell (rounded temperatures)" value="2"/>
</Value>
<Value type="list" genre="config" instance="1" index="7" label="Status auto report" size="1" value="0">
<Help>Status auto report boiler/thermostat report</Help>
<Item label="Disabled" value="0"/>
<Item label="Enabled" value="255"/>
</Value>
<Value type="list" genre="config" instance="1" index="9" label="Thermostat schedule" size="1" value="0">
<Help>Enable/Disable thermostat schedule inside the heating controller.</Help>
<Item label="Disable" value="0"/>
<Item label="Enable" value="255"/>
</Value>
</CommandClass>
<!-- COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 firmware update not supported -->
<CommandClass id="122" getsupported="false" />
<!-- Association Groups -->
<CommandClass id="133">
<Associations num_groups="1">
<Group index="1" max_associations="5" label="Lifeline" />
</Associations>
</CommandClass>
</Product>