66 lines
3.8 KiB
XML
66 lines
3.8 KiB
XML
<?xml version="1.0" encoding="utf-8"?>
|
|
<!--http://benext.eu/static/manual/plugindimmer.pdf-->
|
|
<Product xmlns='http://code.google.com/p/open-zwave/'>
|
|
<!-- Configuration -->
|
|
<CommandClass id="112">
|
|
|
|
<Value type="byte" genre="config" instance="1" index="1" label="Set to Default" value="-1">
|
|
<Help>Set all configuration values to default values (factory settings).</Help>
|
|
</Value>
|
|
|
|
<Value type="list" genre="config" instance="1" index="3" label="Control Type" value="0" size="1">
|
|
<Help>The way the Built-in Dimmer reacts when light is turned on/off with button</Help>
|
|
<Item label="Switch own light on and send a Z-Wave message to all associated nodes (direct and external)" value="0"/>
|
|
<Item label="Don.t switch own light on but only send a Z-Wave message to associated node. (external only)" value="1"/>
|
|
</Value>
|
|
|
|
<Value type="byte" genre="config" instance="1" index="4" label="Dimming enabled" value="1">
|
|
<Help>This parameter is used to enable the dimming option of the product. When disabled the dimming and fading routine are disabled.</Help>
|
|
<Item label="Dimming disabled." value="0"/>
|
|
<Item label="Dimming enabled." value="2"/>
|
|
</Value>
|
|
|
|
<Value type="short" genre="config" instance="1" index="6" label="Maximum Power load" value="125" size="2">
|
|
<Help>The maximum power load in watts when light is turned on, when measured higher then this value the Inline Dimmer is automatically turned off.</Help>
|
|
</Value>
|
|
|
|
<Value type="byte" genre="config" instance="1" index="7" label="Dimming Speed" value="3">
|
|
<Help>The speed of dimming when activated (manual and RF). Dim speed is 1% per value (* 10 ms)</Help>
|
|
</Value>
|
|
|
|
<Value type="byte" genre="config" instance="1" index="8" label="Fading up Speed" value="3">
|
|
<Help>The speed of fading up when activated (manual and RF). Fade speed is 1% per value (* 10 ms)</Help>
|
|
</Value>
|
|
|
|
<Value type="byte" genre="config" instance="1" index="11" label="Auto meter report: percentage" min="0" max="100" size="1" value="2">
|
|
<Help>A percentage that an energy value must be different compared to a previous sent value before an unsolicited meter report is sent. Minimum value = 0% (disabled report) Maximum value = 100%</Help>
|
|
</Value>
|
|
|
|
<Value type="byte" genre="config" instance="1" index="12" label="Auto meter report: watt" min="0" max="255" size="1" value="3">
|
|
<Help>A watt value that an energy value must be different compared to a previous sent value before an unsolicited meter report is sent. Minimum value = 0 watt (disabled report) Maximum value = 255 watt</Help>
|
|
</Value>
|
|
|
|
<Value type="byte" genre="config" instance="1" index="13" label="Auto meter report: time" value="20">
|
|
<Help>A time value that has to be passed compared to a previous sent value before a unsolicited meter report is sent. Minimum value = 10 seconds Maximum value = 255 seconds</Help>
|
|
</Value>
|
|
|
|
<Value type="byte" genre="config" instance="1" index="14" label="Last known status" value="0">
|
|
<Help>What to do with lamp status when power applied. If 0x00: Always switch light off when power applied. If > 0x00: Switch lamp on/off depending on last known lampstatus before power was disconnected.</Help>
|
|
</Value>
|
|
|
|
<Value type="byte" genre="config" instance="1" index="15" label="Fading down speed" value="1">
|
|
<Help>The speed of fading up when activated (manual and RF). Fade speed is 1% per value (* 10 ms)</Help>
|
|
</Value>
|
|
|
|
</CommandClass>
|
|
|
|
<!-- Association Groups -->
|
|
<CommandClass id="133">
|
|
<Associations num_groups="2">
|
|
<Group index="1" max_associations="8" label="BASIC Report on manual switching" auto="false"/>
|
|
<Group index="2" max_associations="1" label="Lifeline" auto="true"/>
|
|
</Associations>
|
|
</CommandClass>
|
|
|
|
</Product>
|