open-zwave/config/BeNext/TagReader500.xml

71 lines
3.0 KiB
XML

<?xml version="1.0" encoding="utf-8"?>
<!--http://www.pepper1.net/zwavedb/device/302-->
<Product xmlns='http://code.google.com/p/open-zwave/'>
<!-- Configuration -->
<CommandClass id="112">
<Value type="list" genre="config" instance="1" index="1" label="Set to Default" size="1" value="170">
<Help>To configure the always awake mode.</Help>
<Item label="Normal" value="170"/>
<Item label="Set all parameters to default" value="255"/>
</Value>
<Value type="byte" genre="config" instance="1" index="2" label="Feedback Time" units="seconds" value="15">
<Help>To configure the time the beep is automatically turned off in seconds.
0x00: Disable, 0x01 - 0xFE: Value in seconds
</Help>
</Value>
<Value type="byte" genre="config" instance="1" index="3" label="Feedback Timeout" units="seconds" value="0">
<Help>
To configure the timeout to wait for a WAKEUP_NO_MORE_INFORMATION before the error beep
is automatically sound. The error beeps are fixed 8 beeps shortly after each other.
0x00: Disabled, 0x01 - 0xFF: Value in seconds
</Help>
</Value>
<Value type="byte" genre="config" instance="1" index="4" label="Feedback beeps per second" value="2">
<Help>
To configure the number of beeps per second. Every beep is fixed about 10ms.
0x00 - 0xFF: Number of beeps per second
</Help>
</Value>
<Value type="list" genre="config" instance="1" index="5" label="Always awake mode" size="1" value="1">
<Help>To configure the always awake mode.</Help>
<Item label="Normal operating" value="1"/>
<Item label="Always awake" value="3"/>
</Value>
<Value type="list" genre="config" instance="1" index="7" label="Operation mode" size="1" value="0">
<Help>The mode that the Tag Reader 500 communicates with the associated gateway.</Help>
<Item label="Gateway mode" value="0"/>
<Item label="Local mode" value="1"/>
</Value>
<Value type="list" genre="config" instance="1" index="8" label="Gateway confirmation" size="1" value="0">
<Help>
In gateway mode it is possible to let the gateway decide if the Tag Reader 500 can arm to home or away.
If gateway indication is disabled the Tag Reader 500 automatically assumes that it can arm and will wait
for a user input of RFID TAG or numeric code.
</Help>
<Item label="Disabled" value="0"/>
<Item label="Enabled" value="1"/>
</Value>
</CommandClass>
<!-- COMMAND_CLASS_ALARM AlarmCmd_Get not supported -->
<CommandClass id="113" getsupported="false"/>
<!-- Association Groups -->
<CommandClass id="133">
<Associations num_groups="1">
<Group index="1" max_associations="5" label="Lifeline"/>
</Associations>
</CommandClass>