open-zwave/config/devolo/rs014G0159.xml

82 lines
3.7 KiB
XML

<?xml version="1.0" encoding="utf-8"?>
<!--
devolo RS 014G0159
http://products.z-wavealliance.org/products/1063
-->
<Product xmlns='http://code.google.com/p/open-zwave/'>
<!-- This thermostat's setpoint descriptions are 0 based, not 1 -->
<CommandClass base="0" override_precision="2" request_flags="4" version="1" name="COMMAND_CLASS_THERMOSTAT_SETPOINT" id="67">
<Instance index="1"/>
<Value index="1" value="0.0" max="0" min="0" verify_changes="false" write_only="false" read_only="false" units="C" label="Heating" instance="1" genre="user" type="decimal"/>
<Value index="2" value="0.0" max="0" min="0" verify_changes="false" write_only="false" read_only="false" units="C" label="Cooling" instance="1" genre="user" type="decimal"/>
<Value index="3" value="0.0" max="0" min="0" verify_changes="false" write_only="false" read_only="false" units="C" label="Unused" instance="1" genre="user" type="decimal"/>
</CommandClass>
<!-- Configuration Parameters -->
<CommandClass id="112">
<Value type="short" index="1" genre="config" label="Temperature Threshold" min="1" max="100" value="5">
<Help>
Temperature Report threshold (1=0.1C)
</Help>
</Value>
<Value type="short" index="2" genre="config" label="Setpoint resolution" min="1" max="100" value="5">
<Help>
Set-point display resolution (1=0.1C)
</Help>
</Value>
<Value type="short" index="3" genre="config" label="Min/Override Setpoint" min="0" max="40" value="12">
<Help>
Min Set-point and override limit
</Help>
</Value>
<Value type="short" index="4" genre="config" label="Max/Override Setpoint" min="0" max="40" value="28">
<Help>
Max Set-point and override limit
</Help>
</Value>
<Value type="list" index="6" genre="config" label="Setpoint control function" size="1" value="1">
<Help>
Setpoint control function
</Help>
<Item label="Disabled" value="0"/>
<Item label="Enabled" value="1"/>
</Value>
<Value type="list" index="7" genre="config" label="Temporarily override scheduler" size="1" value="1">
<Help>
Temporarily override scheduler
</Help>
<Item label="Disabled" value="0"/>
<Item label="Enabled" value="1"/>
</Value>
<Value type="list" index="8" genre="config" label="Setpoint type" size="1" value="1">
<Help>
Setpoint type in thermostat setpoint_reports
</Help>
<Item label="Heating" value="1"/>
<Item label="Cooling" value="2"/>
<Item label="Auto Changeover" value="10"/>
</Value>
<Value type="byte" index="9" genre="config" label="Led on time" min="1" max="5" value="1">
<Help>
Led on time (1=100ms)
</Help>
</Value>
<Value type="short" index="5" genre="config" label="Led Flash Period" min="0" max="65535" value="1">
<Help>
Led Flash Period (0 to 65535 seconds)
</Help>
</Value>
<Value type="byte" index="10" genre="config" label="Number of flash" min="0" max="255" value="5">
<Help>
Number of led flashes (duration)
</Help>
</Value>
<Value type="list" index="11" genre="config" label="Led Color" size="1" value="1">
<Help>
Led Color
</Help>
<Item label="Green" value="1"/>
<Item label="Red" value="2"/>
</Value>
</CommandClass>