<?xml version="1.0" encoding="utf-8"?>
|
|
<Product xmlns='http://code.google.com/p/open-zwave/'>
|
|
<!--
|
|
Dome On/Off Plug-In Switch
|
|
https://docs.domeha.com/#on-off-plug-in-switch
|
|
-->
|
|
<!-- Configuration Parameters -->
|
|
<CommandClass id="112">
|
|
<Value type="list" genre="config" index="1" label="Meter Report" units="level" min="0" max="1" size="1" value="1">
|
|
<Help>
|
|
This parameter enables/disables the METER_REPORT function, which sends periodic reports to Group1 members with information on line voltage, current load, and power and energy consumption.
|
|
Also see Param 2 and 6.
|
|
</Help>
|
|
<Item label="Disable" value="0"/>
|
|
<Item label="Enable" value="1"/>
|
|
</Value>
|
|
<Value type="short" genre="config" index="2" label="Meter Report interval" min="1" max="65535" size="2" units="Seconds" value="300">
|
|
<Help>This parameter sets the amount of time between each successive METER_REPORT signal sent to Group 1 (also see Param 1 and 6.)</Help>
|
|
</Value>
|
|
<Value type="byte" genre="config" index="3" label="Overload Current Level" min="1" max="16" size="1" units="Amp" value="13">
|
|
<Help>
|
|
Sets the maximum current the plug will pass before it cuts off power and sends a NOTIFICATION_EVENT_POWER_MANAGEMENT_OVER_LOAD_DETECTED signal to Group 1 and a BASIC_SET(FF) to Group 2.
|
|
The LED will then blink red once per second until the notification is cleared after the current returns to normal.
|
|
To clear the NOTIFICATION and start monitoring again, the BUTTON must be pushed once (only after the current is back to normal) or a BINARY_SWITCH_SET(FF) command must be sent.
|
|
NOTE: this value must be higher than Param 4.
|
|
</Help>
|
|
</Value>
|
|
<Value type="byte" genre="config" index="4" label="Alert Current Level" min="1" max="15" units="Amp" size="1" value="12">
|
|
<Help>
|
|
Sets the current level at which the On/Off Plug-In Switch will flash its LED yellow, until the current returns to below this level.
|
|
It will NOT cut off current to the device; this functions as a visible warning to the user.
|
|
NOTE: this value must be lower than Param 3.
|
|
</Help>
|
|
</Value>
|
|
<Value type="list" genre="config" index="5" label="Indicator LED" units="level" min="0" max="1" size="1" value="1">
|
|
<Help>This parameter enables or disables the indicator LED.</Help>
|
|
<Item label="Disable" value="0"/>
|
|
<Item label="Enable" value="1"/>
|
|
</Value>
|
|
<Value type="byte" genre="config" index="6" label="Current change METER_REPORT level" units="%" min="1" max="100" size="1" value="5">
|
|
<Help>
|
|
In addition to sending a METER_REPORT to Group 1 in the time interval set by Param 2, the On/Off Plug-In Switch also sends a METER_REPORT when it detects a relative change in current flow.
|
|
This parameter sets this minimum current change amount, in percent, at which point the On/Off Plug-In Switch will send a METER_REPORT to Group 1.
|
|
Also see Param 1 and 2.
|
|
</Help>
|
|
</Value>
|
|
<Value type="list" genre="config" index="7" label="Remember On/Off Status" min="0" max="1" size="1" value="1">
|
|
<Help>
|
|
This parameter sets whether or not the On/Off Plug-In Switch will remember if it was turned on or off when it was last plugged in.
|
|
If enabled, whenever the device is rebooted (plugged in and out of the main outlet,) it will resume its state from before the reboot.
|
|
If disabled, it will turn on every time the device is rebooted.
|
|
</Help>
|
|
<Item label="Disable" value="0"/>
|
|
<Item label="Enable" value="1"/>
|
|
</Value>
|
|
<Value type="list" genre="config" index="8" label="Timer Function" min="0" max="1" size="1" value="1">
|
|
<Help>If this parameter is enabled, whenever the On/Off Plug-In Switch is turned on, it will automatically turn off after a set amount of time (set in Param 9.)</Help>
|
|
<Item label="Disable" value="0"/>
|
|
<Item label="Enable" value="1"/>
|
|
</Value>
|
|
<Value type="short" genre="config" index="9" label="Meter Report interval" min="1" max="65535" size="2" units="Seconds" value="150">
|
|
<Help>
|
|
Sets the time interval before the On/Off Plug-In Switch automatically shuts off.
|
|
See Param 8.
|
|
</Help>
|
|
</Value>
|
|
<Value type="list" genre="config" index="10" label="Locally switch" min="0" max="1" size="1" value="1">
|
|
<Help>If this parameter is enabled, the user can turn the device on or off using the BUTTON.</Help>
|
|
<Item label="Disable" value="0"/>
|
|
<Item label="Enable" value="1"/>
|
|
</Value>
|
|
</CommandClass>
|
|
<!-- Association Groups -->
|
|
<CommandClass id="133">
|
|
<Associations num_groups="3">
|
|
<Group index="1" max_associations="5" label="Lifeline" />
|
|
<Group index="2" max_associations="5" label="Overload Current" />
|
|
<Group index="3" max_associations="5" label="Notification Report" />
|
|
</Associations>
|
|
</CommandClass>
|
|
</Product>
|