open-zwave/config/dome/0201.xml

95 lines
5.4 KiB
XML

<?xml version="1.0" encoding="utf-8"?>
<Product xmlns='http://code.google.com/p/open-zwave/'>
<!--
Dome Door/Window Sensor Pro
https://products.z-wavealliance.org/products/2399
https://products.z-wavealliance.org/ProductManual/File?folder=&filename=Manuals/2399/Gen%202DW%20API%20Manual%20v1.3.pdf
-->
<!-- Configuration Parameters -->
<CommandClass id="112">
<Value type="list" genre="config" index="1" label="Indicator LED" units="level" min="0" max="1" size="1" value="1">
<Help>
This parameter enables or disables the LED Indicator flashing to indicate opening and closing events.
The Door/Window Sensor will always flash the LED Indicator for inclusion, exclusion, tamper, and other system events.
</Help>
<Item label="Disable" value="0"/>
<Item label="Enable" value="1"/>
</Value>
<Value type="list" genre="config" index="2" label="Open/Close Reports Sent" units="level" min="0" max="1" size="1" value="0">
<Help>
This parameter switches the Notification or Binary Sensor report sent when the door opens or closes.
If this parameter is set to 01, the Door/Window Sensor will report closed instead of open when the Magnet and Sensor are pulled apart.
</Help>
<Item label="Reports Closed when Magnet is close" value="0"/>
<Item label="Reports Open when Magnet is close" value="1"/>
</Value>
<Value type="list" genre="config" index="3" label="Report Command Classes" units="level" min="0" max="2" size="1" value="0">
<Help>
By default, the Door/Window Sensor uses the Notification command class to communicate open/close and tamper events.
If this Parameter is set to 1, the device will instead use the Binary Sensor command class.
</Help>
<Item label="Notification and Binary Sensor" value="0"/>
<Item label="Notification" value="1"/>
<Item label="Binary Sensor" value="2"/>
</Value>
<Value type="list" genre="config" index="4" label="Temperature sensor" units="level" min="0" max="1" size="1" value="0">
<Help>
The Door/Window Sensor can also monitor and report ambient temperature conditions.
However, temperature sensing functionality is disabled by default to save battery life, and this configuration parameter is used to enable or disable this feature.
</Help>
<Item label="Disable" value="0"/>
<Item label="Enable" value="1"/>
</Value>
<Value type="byte" genre="config" index="5" label="Temperature Offset" value="0" min="0" max="255" size="1">
<Help>
This Configuration Parameter can offset the temperature value reported by +/- 125 degrees to compensate for temperature variances in a room - for example, the temperature near the ceiling in a room is significantly higher than the average temperature of the same room.
This Parameter accepts a signed 8-bit value with an absolute value of up to 125, and its units are Dependant on Configuration Parameter 07.
Temperature Offset.
0 to 125 : 0 to 125 degrees.
255 to 130 : -1 to -125 degrees.
</Help>
</Value>
<Value type="list" genre="config" index="6" label="Temperature Units" units="level" min="0" max="1" size="1" value="0">
<Help>The Door/Window Sensor can report temperature values in either Celsius or Fahrenheit, and this parameter allows the user to decide which unit is used.</Help>
<Item label="Fahrenheit" value="0"/>
<Item label="Celsius" value="1"/>
</Value>
<Value type="byte" genre="config" index="7" label="Group 2 Basic Set Value" value="255" min="0" max="255" size="1">
<Help>
This parameter sets the value sent by the Basic Set command to Association Group 2 (for more information, see Association Group Info.).
0 Turn Off Device.
1 to 99 Set Device to Value.
255 Turn On Device.
</Help>
</Value>
<Value type="byte" genre="config" index="8" label="Group 4 Basic Set Level Opening" value="255" min="0" max="255" size="1">
<Help>
This parameter sets the value sent by the Basic Set command to Association Group 4.
The Door/Window Sensor sends a Basic Set command to Association Group 4 when the door or window opens (for more information, see Association Group Info.).
0 Turn Off Device.
1 to 99 Set Device to Value.
255 Turn On Device.
</Help>
</Value>
<Value type="byte" genre="config" index="9" label="Group 4 Basic Set Level Closing" value="0" min="0" max="255" size="1">
<Help>
This parameter sets the value sent by the Basic Set command to Association Group 4.
The Door/Window Sensor sends a Basic Set command to Association Group 4 when the door or window opens (for more information, see Association Group Info.).
0 Turn Off Device.
1 to 99 Set Device to Value.
255 Turn On Device.
</Help>
</Value>
</CommandClass>
<!-- Association Groups -->
<CommandClass id="133">
<Associations num_groups="5">
<Group index="1" max_associations="5" label="Lifeline" />
<Group index="2" max_associations="5" label="Tamper Basic Set" />
<Group index="3" max_associations="5" label="Tamper Notification Report" />
<Group index="4" max_associations="5" label="Sensor Basic Set" />
<Group index="5" max_associations="5" label="Sensor Notification Report"/>
</Associations>
</CommandClass>
</Product>