open-zwave/config/fibaro/fgd212.xml

287 lines
22 KiB
XML

<?xml version="1.0" encoding="utf-8"?>
<Product xmlns='http://code.google.com/p/open-zwave/'>
<!--
Fibaro FGD-212
config based on http://manuals.fibaro.com/content/manuals/en/FGD-212/FGD-212-EN-T-v1.3.pdf
-->
<!-- Configuration -->
<CommandClass id="112">
<Value type="byte" genre="config" instance="1" index="1" label="Minimum brightness level" min="1" max="98" units="%" value="1">
<Help>Parameter is set automatically during the calibration process. Options for changing parameter 1-98. Default 1.</Help>
</Value>
<Value type="byte" genre="config" instance="1" index="2" label="Maximum brightness level" min="2" max="99" units="%" value="99">
<Help>Parameter is set automatically during the calibration process. Options for changing parameter 2-99. Default 99.</Help>
</Value>
<Value type="byte" genre="config" instance="1" index="3" label="Incandescence level of dimmable compact fluorescent lamps" min="1" max="99" units="%" value="1">
<Help>Virtual value set as a percentage level between parameters MIN (1%) and MAX. (99%). The Dimmer will set to this value after first switch on. It is required for warming up and switching dimmable compact fluorescent lamps and certain types of light sources. Options for changing parameter 1-99. Default 1.</Help>
</Value>
<Value type="short" genre="config" instance="1" index="4" label="Incandescence time of dimmable compact fluorescent lamps" min="0" max="255" units="sec" value="0">
<Help>This parameter determines the time required for switching compact fluorescent lamps and certain types of light sources. Setting this parameter to 0 will disable the incandescence functionality. Available settings: 0-255 (0s - 25,5s)</Help>
</Value>
<Value type="byte" genre="config" instance="1" index="5" label="The percentage of a dimming step at automatic control" min="1" max="99" units="%" value="1">
<Help>Available settings: 1-99 Default: 1</Help>
</Value>
<Value type="short" genre="config" instance="1" index="6" label="Time of a dimming step at automatic control" min="0" max="255" units="sec" value="1">
<Help>Available settings: 0-255 (0s - 2,55s) Default setting: 1</Help>
</Value>
<Value type="byte" genre="config" instance="1" index="7" label="The percentage of a dimming step at manual control" min="1" max="99" units="%" value="1">
<Help>Available settings: 1-99 Default: 1</Help>
</Value>
<Value type="short" genre="config" instance="1" index="8" label="Time of a dimming step at manual control" min="0" max="255" units="sec" value="5">
<Help>Available settings: 0-255 (0s - 2,55s) Default setting: 1</Help>
</Value>
<Value type="list" genre="config" instance="1" index="9" label="Saving state before power failure" size="1" value="1">
<Help>Saving state before power failure. Default 1.</Help>
<Item label="State NOT saved at power failure, all outputs are set to OFF upon power restore" value="0"/>
<Item label="State saved at power failure, all outputs are set to previous state upon power restore" value="1"/>
</Value>
<Value type="short" genre="config" instance="1" index="10" label="Timer functionality (auto - off)" min="0" max="32767" units="sec" value="0">
<Help>Available settings: 0 - Function disabled; 1-32767 - time to turn off measured in seconds (1s - 9,1h) Default setting: 0</Help>
</Value>
<Value type="list" genre="config" instance="1" index="11" label="Enable/Disable ALL ON/OFF" size="2" value="255">
<Help>Enable/Disable ALL ON/OFF. Default 255.</Help>
<Item label="ALL ON active / ALL OFF active" value="255" />
<Item label="ALL ON disabled/ ALL OFF disabled" value="0" />
<Item label="ALL ON disabled/ ALL OFF active" value="1" />
<Item label="ALL ON active / ALL OFF disabled" value="2" />
</Value>
<Value type="list" genre="config" instance="1" index="13" label="Force auto-calibration" size="1" value="0">
<Help>Changing value of this parameter will force the calibration process.</Help>
<Item label="idle" value="0" />
<Item label="Start auto-calibration of the load without Fibaro Bypass" value="1" />
<Item label="Start auto-calibration of the load with Fibaro Bypass" value="2" />
</Value>
<Value type="list" read_only="true" genre="config" instance="1" index="14" label="Auto-calibration status" size="1" value="0">
<Help>This parameter determines operating mode of the Dimmer (automatic/manual settings).</Help>
<Item label="calibration procedure not performed or Dimmer operates on manual settings" value="0" />
<Item label="Dimmer operates on auto-calibration settings" value="1" />
</Value>
<Value type="byte" genre="config" instance="1" index="15" label="Burnt out bulb detection" min="1" max="99" units="%" value="30">
<Help>Function based on the sudden power variation of a specific value, interpreted as a LOAD ERROR. Available settings: 0 - function disabled; 1-99 - percentage value of power variation, compared to standard power consumption, measured during the calibration procedure (to be interpreted as load error/burnt out bulb) Default setting: 30</Help>
</Value>
<Value type="short" genre="config" instance="1" index="16" label="Time delay of a burnt out bulb" min="0" max="255" units="%" value="5">
<Help>Time of delay (in seconds) for power variation detection, interpreted as a LOAD ERROR or OVERLOAD detection (too much power connected to the Dimmer). Available settings: 0 - detection of a burnt out bulb disabled; 1-255 - delay time in seconds; Default setting: 5</Help>
</Value>
<Value type="byte" genre="config" instance="1" index="19" label="Forced switch on brightness level" min="0" max="99" units="%" value="0">
<Help>If the parameter is active, switching on the Dimmer (S1 single click) will always set this brightness level. Available settings: 0 - function disabled; 1-99 - percentage level of brightness; Default setting: 0</Help>
</Value>
<Value type="list" genre="config" instance="1" index="20" label="Inputs Button/Switch configuration" size="1" value="0">
<Help>Binary inputs type configuration. Default 0.</Help>
<Item label="Mono-stable input (button)" value="0"/>
<Item label="Bi-stable input (switch)" value="1"/>
<Item label="Role blind switch (UP / DOWN) - two switch keys operate the Dimmer" value="2"/>
</Value>
<Value type="list" genre="config" instance="1" index="21" label="The value sent to associated devices on single click" size="1" value="0">
<Help>The value sent to associated devices on single click.</Help>
<Item label="0xFF value is sent, which will set associated devices to their last saved state." value="0"/>
<Item label="Current Dimmer state is sent, which will synchronize brightness level of associated devices (other Dimmers for example)." value="1"/>
</Value>
<Value type="list" genre="config" instance="1" index="22" label="Assign toggle switch status to the device status" size="1" value="0">
<Item label="Device changes status on switch status change" value="0"/>
<Item label="Device status is synchronized with switch status" value="1"/>
</Value>
<Value type="list" genre="config" instance="1" index="23" label="Double click option" size="1" value="1">
<Help>Double-click set lighting at 100%. Default 1.</Help>
<Item label="Disable double click" value="0"/>
<Item label="Enable double click" value="1"/>
</Value>
<Value type="byte" genre="config" instance="1" index="24" label="Command frames sent in 2-nd and 3-rd association groups (S1 associations)" value="0">
<Help>Parameter determines, which actions will not result in sending frames to association groups. Parameter values may be combined, e.g. 1+2=3 means that associations on switching on or off the Dimmer (single click) will not be sent.
Available settings: 0-31
0 - all actions send to association groups;
1 - do not send when switching on the Dimmer (single click);
2 - do not send when switching off the Dimmer (single click);
4 - do not send when changing dimming level (holding and releasing);
8 - do not send on double click;
16 - send 0xFF value on double click;
Default setting: 0</Help>
</Value>
<Value type="byte" genre="config" instance="1" index="25" label="Command frames sent in 4-th and 5-th association groups (S2 associations)" value="0">
<Help>Parameter determines, which actions will not result in sending frames to association groups. Parameter values may be combined, e.g. 1+2=3 means that associations on switching on or off the Dimmer (single click) will not be sent.
Available settings: 0-31
0 - all actions send to association groups;
1 - do not send when switching on the Dimmer (single click);
2 - do not send when switching off the Dimmer (single click);
4 - do not send when changing dimming level (holding and releasing);
8 - do not send on double click;
16 - send 0xFF value on double click;
Default setting: 0</Help>
</Value>
<Value type="list" genre="config" instance="1" index="26" label="The function of 3-way switch" size="1" value="0">
<Help>Switch no. 2 controls the Dimmer additionally (in 3-way switch mode). Function disabled for parameter 20 set to 2 (roller blind switch)</Help>
<Item label="3-way switch function for S2 disabled" value="0"/>
<Item label="3-way switch function for S2 enabled" value="1"/>
</Value>
<Value type="byte" genre="config" instance="1" index="27" label="Associations in Z-Wave network security mode" value="15">
<Help>This parameter defines how commands are sent in specified association groups: as secure or non-secure. Parameter is active only in Z-Wave network security mode. It does not apply to 1st Lifeline group. Parameter values may be combined, e.g. 1+2=3 means that 2nd &amp; 3rd group are sent as secure.
Available settings: 0-15
0 - all groups (II-V) sent as non-secure;
1 - 2nd group sent as secure;
2 - 3rd group sent as secure;
4 - 4th group sent as secure;
8 - 5th group sent as secure;
15 - all groups (II-V) sent as secure;
Default setting: 15</Help>
</Value>
<Value type="list" genre="config" instance="1" index="28" label="Scene activation functionality" size="1" value="0">
<Help>SCENE ID depends on the switch type configurations. Default 0.</Help>
<Item label="Functionality deactivated" value="0"/>
<Item label="Functionality activated" value="1"/>
</Value>
<Value type="list" genre="config" instance="1" index="29" label="Switch functionality of S1 and S2" size="1" value="0">
<Item label="standard mode" value="0"/>
<Item label="S1 operates as S2, S2 operates as S1" value="1"/>
</Value>
<Value type="list" genre="config" instance="1" index="30" label="Load control mode" size="1" value="2">
<Help>Forced auto-calibration will set this parameter value to 2.</Help>
<Item label="forced leading edge control" value="0"/>
<Item label="forced trailing edge control" value="1"/>
<Item label="control mode selected automatically (based on auto-calibration)" value="2"/>
</Value>
<Value type="list" read_only="true" genre="config" instance="1" index="31" label="Load control mode" size="1" value="0">
<Help>Load control mode recognized during auto-calibration.</Help>
<Item label="leading edge" value="0" />
<Item label="trailing edge" value="1" />
</Value>
<Value type="list" genre="config" instance="1" index="32" label="On/Off mode" size="1" value="2">
<Help>Load control mode recognized during auto-calibration.</Help>
<Item label="on/off mode disabled (dimming is possible)" value="0" />
<Item label="on/off mode enabled (dimming is not possible)" value="1" />
<Item label="mode selected automatically" value="2" />
</Value>
<Value type="list" read_only="true" genre="config" instance="1" index="33" label="Dimmability of the load" size="1" value="0">
<Help>Dimmability of the load</Help>
<Item label="Load recognized as dimmable" value="0" />
<Item label="Load recognized as non-dimmable" value="1" />
</Value>
<Value type="list" genre="config" instance="1" index="34" label="Soft-Start functionality" size="1" value="1">
<Help>Time required to warm up the filament of halogen bulb.</Help>
<Item label="no soft-start" value="0" />
<Item label="short soft-start (0.1s)" value="1" />
<Item label="long soft-start (0.5s)" value="2" />
</Value>
<Value type="list" genre="config" instance="1" index="35" label="Auto-calibration after power on" size="1" value="1">
<Help>This parameter determines the trigger of auto-calibration procedure, e.g. power on, load error, etc.</Help>
<Item label="No auto-calibration of the load after power on" value="0" />
<Item label="Auto-calibration performed after first power on" value="1" />
<Item label="Auto-calibration performed after each power on" value="2" />
<Item label="Auto-calibration performed after first power on or after each LOAD ERROR alarm (no load, load failure, burnt out bulb)" value="3" />
<Item label="Auto-calibration performed after each power on or after each LOAD ERROR alarm (no load, load failure, burnt out bulb)," value="4" />
</Value>
<Value type="list" genre="config" instance="1" index="37" label="Behaviour of the Dimmer after OVERCURRENT or SURGE" size="1" value="1">
<Help>Behaviour of the Dimmer after OVERCURRENT or SURGE</Help>
<Item label="device permanently disabled until re-enabling by comand or external switch" value="0" />
<Item label="three attempts to turn on the load" value="1" />
</Value>
<Value type="short" genre="config" instance="1" index="38" label="Brightness level correction for flickering loads" min="0" max="255" value="255">
<Help>Correction reduces spontaneous flickering of some capacitive load (e.g. dimmable lEDs) at certain brightness levels in 2-wire installation. In countries using ripple-control, correction may cause changes in brightness. In this case it is necessary to disable correction or adjust time of correction for flickering loads. Available settings: 0 - automatic correction disabled 1-254 - duration of correction in seconds 255 - automatic correction always enabled Default setting: 255</Help>
</Value>
<Value type="short" genre="config" instance="1" index="39" label="Power limit - OVERLOAD" min="1" max="350" units="Watt" value="250">
<Help>Reaching the defined value will result in turning off the load. Additional apparent power limit of 350VA is active by default. Available settings: 0 - functionality disabled; 1-350 - 1W-350W; Default setting: 250</Help>
</Value>
<Value type="list" genre="config" instance="1" index="40" label="Response to General Purpose Alarm" size="1" value="3">
<Help>Response to General Purpose Alarm; Default 3.</Help>
<Item label="No reaction - no response to alarm frames" value="0"/>
<Item label="ALARM DIMMER ON - device turn ON upon receipt of alarm frame" value="1"/>
<Item label="ALARM DIMMER OFF - device will turn OFF upon receipt of alarm frame" value="2"/>
<Item label="ALARM FLASHING - device will turn ON and OFF periodically" value="3"/>
</Value>
<Value type="list" genre="config" instance="1" index="41" label="Response to Water Flooding Alarm" size="1" value="2">
<Help>Response to Water Flooding Alarm; Default 2.</Help>
<Item label="No reaction - no response to alarm frames" value="0"/>
<Item label="ALARM DIMMER ON - device turn ON upon receipt of alarm frame" value="1"/>
<Item label="ALARM DIMMER OFF - device will turn OFF upon receipt of alarm frame" value="2"/>
<Item label="ALARM FLASHING - device will turn ON and OFF periodically" value="3"/>
</Value>
<Value type="list" genre="config" instance="1" index="42" label="Response to Smoke, CO or CO2 Alarm" size="1" value="3">
<Help>Response to Smoke, CO or CO2 Alarm; Default 3.</Help>
<Item label="No reaction - no response to alarm frames" value="0"/>
<Item label="ALARM DIMMER ON - device turn ON upon receipt of alarm frame" value="1"/>
<Item label="ALARM DIMMER OFF - device will turn OFF upon receipt of alarm frame" value="2"/>
<Item label="ALARM FLASHING - device will turn ON and OFF periodically" value="3"/>
</Value>
<Value type="list" genre="config" instance="1" index="43" label="Response to Temperature Alarm" size="1" value="1">
<Help>Response to Temperature Alarm; Default 1.</Help>
<Item label="No reaction - no response to alarm frames" value="0"/>
<Item label="ALARM DIMMER ON - device turn ON upon receipt of alarm frame" value="1"/>
<Item label="ALARM DIMMER OFF - device will turn OFF upon receipt of alarm frame" value="2"/>
<Item label="ALARM FLASHING - device will turn ON and OFF periodically" value="3"/>
</Value>
<Value type="short" genre="config" instance="1" index="44" label="Time of alarm state" min="1" max="32767" units="sec" value="600">
<Help>Alarm state may be cancelled earlier, as a result of pressing the switches or sending the Z-Wave command frame.</Help>
</Value>
<Value type="list" genre="config" instance="1" index="45" label="OVERLOAD alarm report" size="1" value="1">
<Help>OVERLOAD alarm report (load power consumption too high)</Help>
<Item label="No reaction" value="0"/>
<Item label="Send an alarm frame" value="1"/>
</Value>
<Value type="list" genre="config" instance="1" index="46" label="LOAD ERROR alarm report" size="1" value="1">
<Help>LOAD ERROR alarm report (no load, load failure, burnt out bulb)</Help>
<Item label="No reaction" value="0"/>
<Item label="Send an alarm frame" value="1"/>
</Value>
<Value type="list" genre="config" instance="1" index="47" label="OVERCURRENT alarm report" size="1" value="1">
<Help>OVERCURRENT alarm report (short circuit, burnt out bulb causing overcurrent)</Help>
<Item label="No reaction" value="0"/>
<Item label="Send an alarm frame" value="1"/>
</Value>
<Value type="list" genre="config" instance="1" index="48" label="SURGE alarm report" size="1" value="1">
<Help>SURGE alarm report (Dimmer output overvoltage)</Help>
<Item label="No reaction" value="0"/>
<Item label="Send an alarm frame" value="1"/>
</Value>
<Value type="list" genre="config" instance="1" index="49" label="OVERHEAT and VOLTAGE DROP alarm report" size="1" value="1">
<Help>OVERHEAT (critical temperature) and VOLTAGE DROP (low voltage) alarm report</Help>
<Item label="No reaction" value="0"/>
<Item label="Send an alarm frame" value="1"/>
</Value>
<Value type="byte" genre="config" instance="1" index="50" label="Active power reports" min="0" max="100" units="%" value="10">
<Help>The parameter defines the power level change that will result in a new power report being sent. The value is a percentage of the previous report. Available settings:
0 - power reports disabled;
1-100 (1-100%) - power report threshold;
Default setting: 10 (10%)</Help>
</Value>
<Value type="short" genre="config" instance="1" index="52" label="Periodic active power and energy reports" min="0" max="32767" units="sec" value="3600">
<Help>Parameter 52 defines a time period between consecutive reports. Timer is reset and counted from zero after each report. Available settings:
0 - periodic reports disabled;
1-32767 (1-32767 seconds);
Default setting: 3600 (3600s)</Help>
</Value>
<Value type="short" genre="config" instance="1" index="53" label="Energy reports" min="0" max="255" units="kWh" value="10">
<Help>Energy level change which will result in sending a new energy report. Available settings:
0 - energy reports disabled;
1-255 (0,01 - 2,55 kWh) - report triggering threshold;
Default setting: 10 (0,1 kWh)</Help>
</Value>
<Value type="list" genre="config" instance="1" index="54" label="Self-measurement" size="1" value="0">
<Help>The Dimmer may include active power and energy consumed by itself in reports sent to the main controller.</Help>
<Item label="Self-measurement inactive" value="0" />
<Item label="Self-measurement active" value="1" />
</Value>
<Value type="list" genre="config" instance="1" index="58" label="Method of calculating the active power" size="1" value="0">
<Help>This parameter defines how to calculate active power. This parameter is useful in a case of 2-wire connection with light sources other than resistive. The parameter is set to 0 after forced auto-calibration.</Help>
<Item label="power measurement based on the standard algorithm" value="0" />
<Item label="approximation based on the calibration data" value="1" />
<Item label="approximation based on the control angle" value="2" />
</Value>
<Value type="short" genre="config" instance="1" index="59" label="Approximated power at the maximum brightness level" min="0" max="500" units="Watt" value="0">
<Help>This parameter determines the approximate value of the power that will be reported by the device at its maximum brightness level. This parameter works only when parameter 58 has a value other than 0. Available settings: 0-500 (0-500W) - power consumed by the load at the maximum brightness level. Default setting: 0</Help>
</Value>
</CommandClass>
<!-- Map endpoints to instances -->
<CommandClass id="96" mapping="endpoints" />
<!-- Association Groups -->
<CommandClass id="133">
<Associations num_groups="5">
<Group index="1" max_associations="1" label="Lifeline"/>
<Group index="2" max_associations="8" label="On/Off(S1)"/>
<Group index="3" max_associations="8" label="Dimmer(S1)"/>
<Group index="4" max_associations="8" label="On/Off(S2)"/>
<Group index="5" max_associations="8" label="Dimmer(S2)"/>
</Associations>
</CommandClass>
</Product>