open-zwave/config/fibaro/fgr221.xml

78 lines
4.8 KiB
XML

<?xml version="1.0" encoding="utf-8"?>
<Product xmlns='http://code.google.com/p/open-zwave/'>
<!-- Configuration -->
<CommandClass id="112">
<Value type="list" genre="config" instance="1" index="1" label="Activate / deactivate functions ALL ON / ALL OFF" value="0" size="1">
<Help> </Help>
<Item label="ALL ON disabled/ ALL OFF disable - Default" value="0" />
<Item label="ALL ON disabled/ ALL OFF active" value="1" />
<Item label="ALL ON active / ALL OFF disabled" value="2" />
<Item label="ALL ON active / ALL OFF active" value="255" />
</Value>
<Value type="list" genre="config" instance="1" index="10" label="Turning off the shutter positioning function" value="0" size="1">
<Help> </Help>
<Item label="Turning on the shutter positioning function - Default" value="0"/>
<Item label="Turning off the shutter positioning function" value="1"/>
</Value>
<Value type="list" genre="config" instance="1" index="14" label="14. Inputs Button/Switch configuration" value="0" size="1">
<Help>Binary inputs type configuration</Help>
<Item label="Mono-stable switch (button) - Default" value="0"/>
<Item label="Bi-stable switch (switch)" value="1"/>
<Item label="Single Mono-stable switch" value="2"/>
</Value>
<Value type="byte" genre="config" instance="1" index="20" label="Saving the position Favourites" value="16" size="1">
<Help>Options for changing parameter 1-99, default 16</Help>
</Value>
<Value type="list" genre="config" instance="1" index="30" label="General Alarm, set for shutter no. 1" value="2" size="1">
<Help> </Help>
<Item label="DEACTIVATION - the device does not respond to alarm data frames" value="0"/>
<Item label="OPEN SHUTTER ALARM - the device closes the roller shutter after detecting an alarm" value="1"/>
<Item label="CLOSED SHUTTER ALARM - the device opens the roller shutter after detecting an alarm - Default" value="2"/>
</Value>
<Value type="list" genre="config" instance="1" index="31" label="Alarm of flooding with water, set for relay the shutter." value="0" size="1">
<Help> </Help>
<Item label="DEACTIVATION - the device does not respond to alarm data frames - Default" value="0"/>
<Item label="OPEN SHUTTER ALARM - the device closes the roller shutter after detecting an alarm" value="1"/>
<Item label="CLOSED SHUTTER ALARM - the device opens the roller shutter after detecting an alarm" value="2"/>
</Value>
<Value type="list" genre="config" instance="1" index="32" label="Smoke, CO, CO2 Alarm. Set for the roller shutter." value="1" size="1">
<Help> </Help>
<Item label="DEACTIVATION - the device does not respond to alarm data frames" value="0"/>
<Item label="OPEN SHUTTER ALARM - the device closes the roller shutter after detecting an alarm - Default" value="1"/>
<Item label="CLOSED SHUTTER ALARM - the device opens the roller shutter after detecting an alarm" value="2"/>
</Value>
<Value type="list" genre="config" instance="1" index="33" label="Temperature Alarm, set for roller shutter" value="1" size="1">
<Help> </Help>
<Item label="DEACTIVATION - the device does not respond to alarm data frames" value="0"/>
<Item label="OPEN SHUTTER ALARM - the device closes the roller shutter after detecting an alarm - Default" value="1"/>
<Item label="CLOSED SHUTTER ALARM - the device opens the roller shutter after detecting an alarm" value="2"/>
</Value>
<Value type="byte" genre="config" instance="1" index="41" label="Scene activation functionality" value="0" size="1">
<Help> Only valid for the 1.9 version of FGR221. The device offers the possibility of sending commands compatible with Command class scene activation. Information is sent to devices assigned to association group no. 3. Controllers such as Home Center 2 are able to interpret such commands and based on these commands they activate scenes, to which specific scene IDs have been assigned. The user may expand the functionality of the button connected to inputs S1 and S2 by distinguishing the actions of keys connected to those inputs. For example: double click would activate the scene goodnight and triple click would activate the scene morning.
</Help>
<Item label="Deactivation of functionality - Default" value="0"/>
<Item label="Activation of functionality" value="1"/>
</Value>
</CommandClass>
<!--
<CommandClass id="96" mapping="endpoints" />
-->
<!-- Association Groups -->
<CommandClass id="133">
<Associations num_groups="3">
<Group index="1" max_associations="16" label="Switch click" auto="false"/>
<Group index="2" max_associations="16" label="Switch hold" />
<Group index="3" max_associations="1" label="Lifeline" auto="true"/>
</Associations>
</CommandClass>
</Product>