158 lines
9.2 KiB
XML
158 lines
9.2 KiB
XML
<?xml version="1.0" encoding="utf-8"?>
|
|
|
|
<Product xmlns='http://code.google.com/p/open-zwave/'>
|
|
<!-- Configuration -->
|
|
<CommandClass id="112">
|
|
<Value type="list" genre="config" instance="1" index="1" label="Enable/Disable ALL ON/OFF" value="255" size="1">
|
|
<Help>Enable/Disable ALL ON/OFF</Help>
|
|
<Item label="ALL ON disabled/ ALL OFF disabled" value="0" />
|
|
<Item label="ALL ON disabled/ ALL OFF active" value="1" />
|
|
<Item label="ALL ON active / ALL OFF disabled" value="2" />
|
|
<Item label="ALL ON active / ALL OFF active" value="255" />
|
|
</Value>
|
|
|
|
<Value type="list" genre="config" instance="1" index="3" label="Auto off relay after specified time" value="0" size="1">
|
|
<Help>Auto off relay after specified time, with the possibility of manual override - immediate Off after button push.
|
|
Default value: 0 Manual override disabled</Help>
|
|
<Item label="Manual override disabled" value="0" />
|
|
<Item label="Manual override enabled" value="1" />
|
|
</Value>
|
|
|
|
<Value type="short" genre="config" instance="1" index="4" label="Auto off for relay 1" min="0" max="65535" value="0" >
|
|
<Help>
|
|
Time period for auto off, in milliseconds (0,1 s to 6553,5 s)
|
|
0 - Auto off disabled
|
|
Default value: 0
|
|
</Help>
|
|
</Value>
|
|
|
|
<Value type="short" genre="config" instance="1" index="5" label="Auto off for relay 2" min="0" max="65535" value="0" >
|
|
<Help>
|
|
Time period for auto off, in milliseconds (0,1 s to 6553,5 s)
|
|
0 - Auto off disabled
|
|
Default value: 0
|
|
</Help>
|
|
</Value>
|
|
|
|
<Value type="list" genre="config" instance="1" index="6" label="Separation of association sending (key 1)" value="0" size="1">
|
|
<Help>Activate/Deactivate association sending for group 1 - Also see param #16</Help>
|
|
<Item label="Map status to all devices in group 1 (default)" value="0" />
|
|
<Item label="Map OFF status to all devices in group 1, Double click on key 1 will send ON to all devices in group 1, all dimmers set to prev.value" value="1" />
|
|
<Item label="Map OFF status to all devices in group 1, Double click on key 1 will send ON to all devices in group 1, all dimmers set to 100%" value="2" />
|
|
</Value>
|
|
|
|
<Value type="list" genre="config" instance="1" index="7" label="Control key #2 behaviour" value="1" size="1">
|
|
<Help>Key no.2 is not represented by any physical device except of devices on association list.
|
|
This functionality prevents of lack of reaction on pressing key no.2 through polling devices
|
|
from association list one by one and checking their actual statuses.
|
|
</Help>
|
|
<Item label="Device status is not checked" value="0" />
|
|
<Item label="Device status is checked" value="1" />
|
|
</Value>
|
|
|
|
<Value type="list" genre="config" instance="1" index="13" label="Inputs behaviour" value="0" size="1">
|
|
<Help>In case of bi-stable switches, define their behaviour (toggle or follow)</Help>
|
|
<Item label="Toggle" value="0"/>
|
|
<Item label="Follow switch contact (closed=ON, open=OFF)" value="1"/>
|
|
</Value>
|
|
|
|
<Value type="list" genre="config" instance="1" index="14" label="Inputs Button/Switch configuration" value="1" size="1">
|
|
<Help>Binary inputs type configuration</Help>
|
|
<Item label="Mono-stable input (button)" value="0"/>
|
|
<Item label="Bi-stable input (switch)" value="1"/>
|
|
</Value>
|
|
|
|
<Value type="list" genre="config" instance="1" index="15" label="Dimmer/Roller shutter control" value="0" size="1">
|
|
<Help>Enable/Disable operation of dimmer or roller shutter devices associated to group 1.
|
|
Available only when using mono-stable inputs (buttons) - Hold button 1 or double-tap for operation</Help>
|
|
<Item label="Disable Dimmer/Roller shutter control" value="0"/>
|
|
<Item label="Enable Dimmer/Roller shutter control" value="1"/>
|
|
</Value>
|
|
|
|
<Value type="list" genre="config" instance="1" index="16" label="Saving state before power failure" value="1" size="1">
|
|
<Help>Saving state before power failure</Help>
|
|
<Item label="State NOT saved at power failure, all outputs are set to OFF upon power restore" value="0"/>
|
|
<Item label="State saved at power failure, all outputs are set to previous state upon power restore" value="1"/>
|
|
</Value>
|
|
|
|
<Value type="list" genre="config" instance="1" index="30" label="Relay 1: Response to General Alarm" value="3" size="1">
|
|
<Help></Help>
|
|
<Item label="DEACTIVATION - no response to alarm frames" value="0"/>
|
|
<Item label="ALARM RELAY ON - relay will turn ON upon receipt of alarm frame" value="1"/>
|
|
<Item label="ALARM RELAY OFF - relay will turn OFF upon receipt of alarm frame" value="2"/>
|
|
<Item label="ALARM FLASHING - relay will turn ON and OFF periodically (see param.39)" value="3"/>
|
|
</Value>
|
|
|
|
<Value type="list" genre="config" instance="1" index="31" label="Relay 1: Response to Water Flood Alarm" value="2" size="1">
|
|
<Help></Help>
|
|
<Item label="DEACTIVATION - no response to alarm frames" value="0"/>
|
|
<Item label="ALARM RELAY ON - relay will turn ON upon receipt of alarm frame" value="1"/>
|
|
<Item label="ALARM RELAY OFF - relay will turn OFF upon receipt of alarm frame" value="2"/>
|
|
<Item label="ALARM FLASHING - relay will turn ON and OFF periodically (see param.39)" value="3"/>
|
|
</Value>
|
|
|
|
<Value type="list" genre="config" instance="1" index="32" label="Relay 1: Response to Smoke, CO, CO2 Alarm" value="3" size="1">
|
|
<Help></Help>
|
|
<Item label="DEACTIVATION - no response to alarm frames" value="0"/>
|
|
<Item label="ALARM RELAY ON - relay will turn ON upon receipt of alarm frame" value="1"/>
|
|
<Item label="ALARM RELAY OFF - relay will turn OFF upon receipt of alarm frame" value="2"/>
|
|
<Item label="ALARM FLASHING - relay will turn ON and OFF periodically (see param.39)" value="3"/>
|
|
</Value>
|
|
|
|
<Value type="list" genre="config" instance="1" index="33" label="Relay 1: Response to Temperature Alarm" value="1" size="1">
|
|
<Help></Help>
|
|
<Item label="DEACTIVATION - no response to alarm frames" value="0"/>
|
|
<Item label="ALARM RELAY ON - relay will turn ON upon receipt of alarm frame" value="1"/>
|
|
<Item label="ALARM RELAY OFF - relay will turn OFF upon receipt of alarm frame" value="2"/>
|
|
<Item label="ALARM FLASHING - relay will turn ON and OFF periodically (see param.39)" value="3"/>
|
|
</Value>
|
|
|
|
<Value type="short" genre="config" instance="1" index="39" label="ALARM FLASHING alarm time" value="600" size="2">
|
|
<Help>Amount of time (ms) the device keeps on flashing after receipt of Alarm Frame</Help>
|
|
</Value>
|
|
|
|
<Value type="list" genre="config" instance="1" index="40" label="Relay 2: Response to General Alarm" value="3" size="1">
|
|
<Help></Help>
|
|
<Item label="DEACTIVATION - no response to alarm frames" value="0"/>
|
|
<Item label="ALARM RELAY ON - relay will turn ON upon receipt of alarm frame" value="1"/>
|
|
<Item label="ALARM RELAY OFF - relay will turn OFF upon receipt of alarm frame" value="2"/>
|
|
<Item label="ALARM FLASHING - relay will turn ON and OFF periodically (see param.39)" value="3"/>
|
|
</Value>
|
|
|
|
<Value type="list" genre="config" instance="1" index="41" label="Relay 2: Response to Water Flood Alarm" value="2" size="1">
|
|
<Help></Help>
|
|
<Item label="DEACTIVATION - no response to alarm frames" value="0"/>
|
|
<Item label="ALARM RELAY ON - relay will turn ON upon receipt of alarm frame" value="1"/>
|
|
<Item label="ALARM RELAY OFF - relay will turn OFF upon receipt of alarm frame" value="2"/>
|
|
<Item label="ALARM FLASHING - relay will turn ON and OFF periodically (see param.39)" value="3"/>
|
|
</Value>
|
|
|
|
<Value type="list" genre="config" instance="1" index="42" label="Relay 2: Response to Smoke, CO, CO2 Alarm" value="3" size="1">
|
|
<Help></Help>
|
|
<Item label="DEACTIVATION - no response to alarm frames" value="0"/>
|
|
<Item label="ALARM RELAY ON - relay will turn ON upon receipt of alarm frame" value="1"/>
|
|
<Item label="ALARM RELAY OFF - relay will turn OFF upon receipt of alarm frame" value="2"/>
|
|
<Item label="ALARM FLASHING - relay will turn ON and OFF periodically (see param.39)" value="3"/>
|
|
</Value>
|
|
|
|
<Value type="list" genre="config" instance="1" index="43" label="Relay 2: Response to Temperature Alarm" value="1" size="1">
|
|
<Help></Help>
|
|
<Item label="DEACTIVATION - no response to alarm frames" value="0"/>
|
|
<Item label="ALARM RELAY ON - relay will turn ON upon receipt of alarm frame" value="1"/>
|
|
<Item label="ALARM RELAY OFF - relay will turn OFF upon receipt of alarm frame" value="2"/>
|
|
<Item label="ALARM FLASHING - relay will turn ON and OFF periodically (see param.39)" value="3"/>
|
|
</Value>
|
|
</CommandClass>
|
|
|
|
<CommandClass id="96" mapping="endpoints" />
|
|
<!-- Association Groups -->
|
|
<CommandClass id="133">
|
|
<Associations num_groups="3">
|
|
<Group index="1" max_associations="5" label="Key no 1" auto="false"/>
|
|
<Group index="2" max_associations="5" label="Key no 2"/>
|
|
<Group index="3" max_associations="1" label="Lifeline" auto="true"/>
|
|
</Associations>
|
|
</CommandClass>
|
|
|
|
</Product>
|