66 lines
3.4 KiB
XML
66 lines
3.4 KiB
XML
<?xml version="1.0" encoding="utf-8"?>
|
|
|
|
<Product xmlns='http://code.google.com/p/open-zwave/'>
|
|
<!--
|
|
Fibaro FGT-001
|
|
https://products.z-wavealliance.org/products/2586
|
|
config based on https://manuals.fibaro.com/content/manuals/en/FGT-001/FGT-001-EN-T-v1.0.pdf
|
|
-->
|
|
<!-- Thermostat -->
|
|
<CommandClass id="64" name="COMMAND_CLASS_THERMOSTAT_MODE">
|
|
<Value type="list" genre="user" instance="1" index="0" label="Mode" units="" read_only="false" write_only="false" min="0" max="255" value="0">
|
|
<Item label="Off" value="0"/>
|
|
<Item label="Heat" value="1"/>
|
|
<Item label="Manual Valve Control" value="31"/>
|
|
</Value>
|
|
<SupportedModes>
|
|
<Mode index="0" label="Off"/>
|
|
<Mode index="1" label="Heat"/>
|
|
<Mode index="31" label="Manual Valve Control"/>
|
|
</SupportedModes>
|
|
</CommandClass>
|
|
|
|
<CommandClass id="67" name="COMMAND_CLASS_THERMOSTAT_SETPOINT" version="1" request_flags="4" create_vars="true" base="0">
|
|
<Instance index="1"/>
|
|
<Value type="decimal" genre="user" instance="1" index="1" label="Heating" units="C" read_only="false" write_only="false" min="16" max="24" value="20"/>
|
|
</CommandClass>
|
|
|
|
<!-- Configuration -->
|
|
<CommandClass id="112">
|
|
<Value type="int" genre="config" instance="1" index="1" label="Override Schedule duration" min="10" max="10000" value="240">
|
|
<Help>This parameter determines duration of Override Schedule after turning the knob while normal schedule is active (set by Schedule CC).</Help>
|
|
</Value>
|
|
<Value type="int" genre="config" instance="1" index="2" label="Additional functions" value="1" size="4">
|
|
<Help>This parameter allows to enable different additional functions of the device.
|
|
1) Enable open window detector
|
|
2) Enable fast open window detector
|
|
4) Increase receiver sensitivity (shortens battery life)
|
|
8) Enable LED indications when controlling remotely
|
|
16) Protect from setting Full ON and Full OFF mode by turning the knob manually
|
|
NOTE: Parameter values may be combined, e.g. 1+8=9 means than open window detector and LED indications when controlling remotely are enabled.
|
|
</Help>
|
|
</Value>
|
|
<Value type="list" genre="config" instance="1" index="3" label="Additional functions status" value="0" size="4" read_only="true">
|
|
<Help>This parameter allows to check status of different additional functions.
|
|
1) Optional temperature sensor connected and operational
|
|
2) Open window detected
|
|
NOTE: Parameter values may be combined, e.g. 1+2=3 means than optional sensor works properly and open window detection was triggered.
|
|
</Help>
|
|
<Item label="None" value="0"/>
|
|
<Item label="Optional temperature sensor connected and operational" value="1"/>
|
|
<Item label="Open window detected" value="2"/>
|
|
<Item label="Optional temperature sensor and Open window detected" value="3"/>
|
|
</Value>
|
|
</CommandClass>
|
|
|
|
<!-- Map endpoints to instances -->
|
|
<CommandClass id="96" mapping="endpoints"/>
|
|
|
|
<!-- Association Groups -->
|
|
<CommandClass id="133">
|
|
<Associations num_groups="1">
|
|
<Group index="1" max_associations="1" label="Lifeline"/>
|
|
</Associations>
|
|
</CommandClass>
|
|
</Product>
|