<?xml version="1.0" encoding="utf-8"?>
|
|
<Product xmlns='http://code.google.com/p/open-zwave/'>
|
|
<!-- Configuration Parameters -->
|
|
<CommandClass id="112">
|
|
<Value type="byte" index="0" genre="config" label="Unidentified Parameter" units="" min="0" max="255" value="5">
|
|
<Help>
|
|
Parameter #0 is undocumented: let us know if you know what it does!
|
|
Attributes (type, units, min and max) are wild guesses, except default value.
|
|
</Help>
|
|
</Value>
|
|
<Value type="byte" index="1" genre="config" label="On Time" units="minutes" min="0" max="255" value="20">
|
|
<Help>
|
|
On Time sets the number of minutes that the lights stay on when
|
|
motion has not been detected.
|
|
A value of 0 On Time is a special mode where the lights are
|
|
constantly sent a command to turn them on whenever motion is
|
|
detected. The device will NOT turn the lights off in this mode.
|
|
Note that this mode will significantly shorten battery life.
|
|
Recommended values:
|
|
5 min for hallways.
|
|
20 min for an office environment.
|
|
60 min for a library or other room where someone may be sitting
|
|
still for a long time.
|
|
This may be inaccurate, but default for Homeseer HSM100 may actually be 3 minutes, instead of 20?
|
|
</Help>
|
|
</Value>
|
|
<Value type="byte" index="2" genre="config" label="On Level" min="-1" max="99" value="99">
|
|
<Help>
|
|
OnLevel is the value sent by the Z-Wave BASIC_SET command to all Association Group 2 nodes when motion is detected.
|
|
A value of 0 will turn the lights off (not recommended).
|
|
A value between 1 and 99 will set the dim level to between 1% and 99% (99% is full on).
|
|
A value of -1 will turn the light on which depends on the device but most will set the dim level to the last dim setting.
|
|
</Help>
|
|
</Value>
|
|
<Value type="byte" index="3" genre="config" label="Lite Minutes" min="0" max="255" value="5">
|
|
<Help>
|
|
LiteMinutes. A Luminance report is sent to the system controller every LiteMin minutes.
|
|
A value of zero turns this mode off. Luminance values can still be obtained at any time by the home control application in this mode.
|
|
</Help>
|
|
</Value>
|
|
<Value type="byte" index="4" genre="config" label="Temp Minutes" min="0" max="255" value="5">
|
|
<Help>
|
|
TempMinutes. A Temperature report is sent to the controller every TempMin minutes.
|
|
A value of zero turns this mode off. Temperature values can still be obtained at any time by polling the status of the temperature sensor.
|
|
</Help>
|
|
</Value>
|
|
<Value type="byte" index="5" genre="config" label="Temp Adj" min="-128" max="127" value="0">
|
|
<Help>
|
|
TempAdj. TempAdj is a twos-complement number that is used to adjust the temperature reading to make it more accurate. The value is in tenths of degree Fahrenheit. The temperature reading can be adjusted by +12.7F to -12.8F. A value of 1 will adjust the temperature reading by +0.1F. A value of -1 will adjust the temperature by -0.1F. A value of 123 will adjust the temperature by +12.3F.
|
|
</Help>
|
|
</Value>
|
|
</CommandClass>
|
|
<!-- Association Groups -->
|
|
<CommandClass id="133">
|
|
<Associations num_groups="2">
|
|
<Group index="1" max_associations="1" label="Motion Notification" />
|
|
<Group index="2" max_associations="4" label="Motion Control" auto="true"/>
|
|
</Associations>
|
|
</CommandClass>
|
|
</Product>
|