open-zwave/config/idlock/idlock150.xml

110 lines
4.6 KiB
XML

<?xml version="1.0" encoding="utf-8"?>
<Product xmlns='http://code.google.com/p/open-zwave/'>
<!-- Configuration Parameters -->
<!--COMMAND_CLASS_CONFIGURATION_V1-->
<CommandClass id="112">
<Value type="list" index="1" genre="config" label="Door Lock Mode" units="" min="0" max="3" value="1" size="1">
<Help>
Door Lock Mode
Autolock Mode, Manual lock mode, Activate Away Mode, Deactivate Away Mode
Default Value : 1 ( Disable Away / Auto Lock Mode )
</Help>
<Item label="Disable Away, Manual Lock" value="0" />
<Item label="Disable Away, Auto Lock" value="1" />
<Item label="Enable Away, Manual Lock" value="2" />
<Item label="Enable Away, Auto Lock" value="3" />
</Value>
<Value type="list" index="2" genre="config" label="RFID Registration Configuration" units="" min="1" max="8" value="5" size="1">
<Help>
RFID Registration Configuration
IDLocks can use up to 50 RFID cards. In order to use a RFID, RFID has to be registered by z-wave configuration command class.
RFID Configuration with Z-wave is only valid for ID Lock 101.
Configuration Parameters are as below. Default value is 0x05 (Not in progress).
ID Lock 150 will always report 0x05 as this feature is not supported by this door lock model.
Configuration Set in case of starting to register from gateway
</Help>
<Item label="Begin RFID Registering mode on the door lock" value="1" />
<Item label="Not in progress" value="5" />
<Item label="RFID Database clear" value="7" />
<Item label="RFID Registering mode stop" value="8" />
</Value>
<Value type="list" index="3" genre="config" label="Door Hinge Position" units="" min="0" max="3" value="0" size="1">
<Help>
Door Hinge Position
Default Value : 0 (Right Handle)
</Help>
<Item label="Right Handle" value="0" />
<Item label="Left Handle" value="1" />
</Value>
<Value type="list" index="4" genre="config" label="Door Audio Volume Level" units="" min="0" max="6" value="5" size="1" write_only="true">
<Help>
Door Audio Volume Level
This parameter is a set only parameter. If the value is changed locally on the door lock, this value will not change.
Default Value : 5
</Help>
<Item label="No Sound" value="0" />
<Item label="Level 1" value="1" />
<Item label="Level 2" value="2" />
<Item label="Level 3" value="3" />
<Item label="Level 4" value="4" />
<Item label="Level 5" value="5" />
<Item label="Max. Sound Level" value="6" />
</Value>
<Value type="list" index="5" genre="config" label="Door ReLock Mode" units="" min="0" max="1" value="1" size="1">
<Help>
Door ReLock Mode
Default Value: 1 (Enabled)
</Help>
<Item label="Disabled" value="0" />
<Item label="Enabled" value="1" />
</Value>
<Value type="list" index="6" genre="config" label="Service PIN Mode" units="" min="0" max="9" value="0" size="1" write_only="true">
<Help>
Service PIN Mode
A configuration get command on this parameter returns the latest set parameter value (set by Z-wave).
This is a set only value, if changed locally on keypad these values are not changed on Z-wave module. Value 5, 6 and 7 are for future use on door lock.
Default Value: 0 (Deactivated)
</Help>
<Item label="Deactivated" value="0" />
<Item label="1 times used" value="1" />
<Item label="2 times used" value="2" />
<Item label="5 times used" value="3" />
<Item label="10 times used" value="4" />
<Item label="Not used (for future use)" value="5" />
<Item label="Not used (for future use)" value="6" />
<Item label="Not used (for future use)" value="7" />
<Item label="12 Hours used" value="8" />
<Item label="24 Hours used" value="9" />
</Value>
<Value type="byte" index="7" genre="config" label="Door Lock Model Type" units="" min="101" max="150" value="150" read_only="true">
<Help>
Door Lock Model Type
This configuration is only accepted by configuration get command
It is a read only parameter. Default value depends on the door lock model type.
</Help>
</Value>
<Value type="int" index="10" genre="config" label="Retrieve RFID Information" units="">
<Help>
Configuration Report for retriving the RFID information
Byte 1: Para1 (msb)
Byte 2: Para2
Byte 3: Para3
Byte 4: Para4 (lsb)
</Help>
</Value>
</CommandClass>
<!-- Association Groups -->
<!--COMMAND_CLASS_ASSOCIATION_V2-->
<CommandClass id="133">
<Instance index="1" />
<Associations num_groups="1">
<Group index="1" max_associations="5" label="Lifeline"/>
</Associations>
</CommandClass>
</Product>