<?xml version="1.0" encoding="utf-8"?>
<Product xmlns='http://code.google.com/p/open-zwave/'>
<!--
NorthQ NQ-92021 Power Reader & Power Manager
http://products.z-wavealliance.org/products/69
http://northq.com/wp-content/uploads/2016/01/Technical-Integration.pdf
-->
<!-- Configuration Parameters -->
<CommandClass id="112">
<Value type="int" index="1" genre="config" label="Pulse factor" units="pulses" min="10" max="1000000" value="10000">
<Help>How many pulses are counted per 10 kWh.</Help>
</Value>
<Value type="list" index="2" genre="config" label="Sensor type" units="" min="1" max="2" value="1" size="1">
<Help>Defines the meter type on which the Power Reader is placed</Help>
<Item label="Pulse Meter" value="1"/>
<Item label="Rotating Wheel" value="2"/>
</Value>
<Value type="byte" index="3" genre="config" label="IR Listen period" units="" min="0" max="127" value="0">
<Help>Additional time for feedback measurement.Should always be 0.</Help>
</Value>
<Value type="byte" index="4" genre="config" label="IR Pulse Width" units="" min="0" max="127" value="50">
<Help>Adjusts transmit signal so received signal will in average be equal to this values. Auto calibration might select another value than this.</Help>
</Value>
<Value type="byte" index="5" genre="config" label="Poll / Wake up frequency" units="seconds" min="1" max="50" value="20" >
<Help>Wake device up this many times per second. This value also controls number of measurements per second on mechanical meters.</Help>
</Value>
<Value type="int" index="8" genre="config" label="Wake up interval" units="seconds" min="1" max="32767" value="900" read_only="true" >
<Help>Do not use. Set this value using WAKE_UP_INTERVAL_SET instead.</Help>
</Value>
<Value type="int" index="9" genre="config" label="Pulse count" units="pulses/kWh" min="0" max="2147483647" value="0" >
<Help>Current pulse count in device (pulse count / pulse factor = kWh).</Help>
</Value>
<Value type="short" index="10" genre="config" label="Keep alive period" units="second" size="2" min="1" max="32767" value="5">
<Help>set to the number of seconds that it will take the controlling node to send a response / request to the wake up notification</Help>
</Value>
<Value type="int" index="11" genre="config" label="Real-time mode" units="pulses/kWh" min="0" max="32767" value="0" >
<Help>Set this to enter real-time mode from remote. Contains seconds * poll frequency before going back to sleep. If you press the button once this value will be set.</Help>
</Value>
</CommandClass>