<?xml version="1.0" encoding="utf-8"?>
|
|
<!--
|
|
Oomi FT111 Nano Dimmer
|
|
https://products.z-wavealliance.org/products/2765
|
|
-->
|
|
<Product xmlns='http://code.google.com/p/open-zwave/'>
|
|
<!-- Configuration Parameters -->
|
|
<CommandClass id="112">
|
|
<Value type="list" index="3" genre="config" label="Over current protection" units="" min="0" max="1" size="1" value="1">
|
|
<Help>Output Load will be turned off automatically after 30 seconds and if the current overrun 1.5A.</Help>
|
|
<Item label="Disable" value="0"/>
|
|
<Item label="Enable" value="1"/>
|
|
</Value>
|
|
<Value type="list" index="4" genre="config" label="Over heat protection" units="" min="0" max="1" size="1" value="0">
|
|
<Help>Output load will be closed after 30 seconds if the temperature inside the product exceeds 100C.</Help>
|
|
<Item label="Disable" value="0"/>
|
|
<Item label="Enable" value="1"/>
|
|
</Value>
|
|
<Value type="list" index="20" genre="config" label="Status re-power on" size="1" value="0">
|
|
<Help>Configure the output load status after re-power on</Help>
|
|
<Item label="The last status before the power outage" value="0"/>
|
|
<Item label="Always on" value="1"/>
|
|
<Item label="Always off" value="2"/>
|
|
</Value>
|
|
<Value type="list" index="80" genre="config" label="Notification report association group 1" units="" size="1" value="3">
|
|
<Help>To set which notification would be sent to the associated nodes in association group 1 when the state of output load is changed</Help>
|
|
<Item label="None" value="0"/>
|
|
<Item label="Hail" value="1"/>
|
|
<Item label="Basic" value="2"/>
|
|
<Item label="Send Multilevel Switch report" value="3"/>
|
|
<Item label="Send Hail CC when using the manual switch to change the load state" value="4"/>
|
|
</Value>
|
|
<Value type="list" index="81" genre="config" label="Notification report using the external switch 1" units="" size="1" value="1">
|
|
<Help>To set which notification would be sent to the associated nodes in association group 3 when using the external switch 1 to switch the loads</Help>
|
|
<Item label="None" value="0"/>
|
|
<Item label="Basic" value="1"/>
|
|
</Value>
|
|
<Value type="list" index="82" genre="config" label="Notification report using the external switch 2" units="" size="1" value="1">
|
|
<Help>To set which notification would be sent to the associated nodes in association group 4 when using the external switch 2 to switch the loads</Help>
|
|
<Item label="None" value="0"/>
|
|
<Item label="Basic" value="1"/>
|
|
</Value>
|
|
<Value type="int" index="85" genre="config" label="State appointment 1" value="2566920192">
|
|
<Help>State appointment
|
|
Set the ON time of output load.
|
|
Value1 = 0, disable or = non zero, enable (day, bit0 - bit6 represent Mon to Sun).
|
|
Value2 = ON (hour)
|
|
Value3 = ON (minute)
|
|
Value4 = ON (brightness level)
|
|
</Help>
|
|
</Value>
|
|
<Value type="int" index="86" genre="config" label="State appointment 2" value="8960">
|
|
<Help>State appointment
|
|
Set the ON time of output load.
|
|
Value1 = 0, disable or = non zero, enable (day, bit0 - bit6 represent Mon to Sun).
|
|
Value2 = ON (hour)
|
|
Value3 = ON (minute)
|
|
Value4 = ON (brightness level)
|
|
</Help>
|
|
</Value>
|
|
<Value type="list" index="90" genre="config" label="Enable/disable the parameter 91 and 92" units="" size="1" value="0">
|
|
<Help>Enables/disables parameter 91 and 92</Help>
|
|
<Item label="Disable" value="0"/>
|
|
<Item label="Enable" value="1"/>
|
|
</Value>
|
|
<Value type="short" index="91" genre="config" label="Minimum Change to send Report (Watt)" units="watts" min="0" max="6000" size="2" value="25">
|
|
<Help>The value represents the minimum change in wattage for a Report to be sent (default 25 W)</Help>
|
|
</Value>
|
|
<Value type="byte" index="92" genre="config" label="Minimum Change to send Report (%)" units="%" min="0" max="100" value="5">
|
|
<Help>The value represents the minimum percentage change in wattage for a Report to be sent (Default 5)</Help>
|
|
</Value>
|
|
<Value type="button" index="100" genre="config" label="Default Group Reports" units="" write_only="true" affects="101,102,103">
|
|
<Help>Set report types for groups 1, 2 and 3 to default.</Help>
|
|
</Value>
|
|
<Value type="int" index="101" genre="config" label="Report type sent in Reporting Group 1" units="" value="0">
|
|
<Help>
|
|
Defines the type of report sent for reporting group 1.
|
|
1 is meter report for voltage.
|
|
2 is meter report for current.
|
|
4 is meter report for watts.
|
|
8 is meter report for kilowatts.
|
|
Value 1 (msb) Reserved
|
|
Value 2 Reserved
|
|
Value 3 Reserved
|
|
Value 4 (lsb) bits 7-4 reserved
|
|
bit 3 current
|
|
bit 2 voltage
|
|
bit 1 watt
|
|
bit 0 kWh
|
|
</Help>
|
|
</Value>
|
|
<Value type="int" index="102" genre="config" label="Report type sent in Reporting Group 2" units="" value="0">
|
|
<Help>
|
|
Defines the type of report sent for reporting group 2.
|
|
1 is meter report for voltage.
|
|
2 is meter report for current.
|
|
4 is meter report for watts.
|
|
8 is meter report for kilowatts.
|
|
Value 1 (msb) Reserved
|
|
Value 2 Reserved
|
|
Value 3 Reserved
|
|
Value 4 (lsb) bits 7-4 reserved
|
|
bit 3 current
|
|
bit 2 voltage
|
|
bit 1 watt
|
|
bit 0 kWh
|
|
</Help>
|
|
</Value>
|
|
<Value type="int" index="103" genre="config" label="Report type sent in Reporting Group 3" units="" value="0">
|
|
<Help>
|
|
Defines the type of report sent for reporting group 3.
|
|
1 is meter report for voltage.
|
|
2 is meter report for current.
|
|
4 is meter report for watts.
|
|
8 is meter report for kilowatts.
|
|
Value 1 (msb) Reserved
|
|
Value 2 Reserved
|
|
Value 3 Reserved
|
|
Value 4 (lsb) bits 7-4 reserved
|
|
bit 3 current
|
|
bit 2 voltage
|
|
bit 1 watt
|
|
bit 0 kWh
|
|
</Help>
|
|
</Value>
|
|
<Value type="button" index="110" genre="config" label="Set 111-113 to default" units="" write_only="true" value="0" affects="111,112,113">
|
|
<Help>Set time interval for sending reports for groups 1, 2 and 3 to default.</Help>
|
|
</Value>
|
|
<Value type="int" index="111" genre="config" label="Send Interval for Reporting Group 1" units="seconds" min="0" max="2147483647" value="3">
|
|
<Help>Defines the time interval when the defined report for group 1 is sent.</Help>
|
|
</Value>
|
|
<Value type="int" index="112" genre="config" label="Send Interval for Reporting Group 2" units="seconds" min="0" max="2147483647" value="600">
|
|
<Help>Defines the time interval when the defined report for group 2 is sent.</Help>
|
|
</Value>
|
|
<Value type="int" index="113" genre="config" label="Send Interval for Reporting Group 3" units="seconds" min="0" max="2147483647" value="600">
|
|
<Help>Defines the time interval when the defined report for group 3 is sent.</Help>
|
|
</Value>
|
|
<Value type="list" index="120" genre="config" label="Set the external switch mode for S1" units="" min="0" max="4" size="1" value="0">
|
|
<Help>When the mode is determined, this mode value will not be reset after exclusion</Help>
|
|
<Item label="Unidentified" value="0"/>
|
|
<Item label="2-state switch" value="1"/>
|
|
<Item label="3-way switch" value="2"/>
|
|
<Item label="Momentary button" value="3"/>
|
|
<Item label="Enter automatic identification" value="4"/>
|
|
</Value>
|
|
<Value type="list" index="121" genre="config" label="Set the external switch mode for S2" units="" min="0" max="4" size="1" value="0">
|
|
<Help>When the mode is determined, this mode value will not be reset after exclusion</Help>
|
|
<Item label="Unidentified" value="0"/>
|
|
<Item label="2-state switch" value="1"/>
|
|
<Item label="3-way switch" value="2"/>
|
|
<Item label="Momentary button" value="3"/>
|
|
<Item label="Enter automatic identification" value="4"/>
|
|
</Value>
|
|
<Value type="list" index="122" genre="config" label="Touch panel port state" units="" min="0" max="5" size="1" value="0" read_only="true">
|
|
<Help>Get the state of touch panel port</Help>
|
|
<Item label="Not connected" value="0"/>
|
|
<Item label="Connected" value="5"/>
|
|
</Value>
|
|
<Value type="list" index="123" genre="config" label="Control destination for external switch S1" units="" min="0" max="3" size="1" value="3">
|
|
<Help>Set the control destination for external switch S1</Help>
|
|
<Item label="Output loads of itself" value="1"/>
|
|
<Item label="Other nodes" value="2"/>
|
|
<Item label="Output loads of itself and other nodes" value="3"/>
|
|
</Value>
|
|
<Value type="list" index="124" genre="config" label="Control destination for external switch S2" units="" min="1" max="3" size="1" value="3">
|
|
<Help>Set the control destination for external switch S2</Help>
|
|
<Item label="Output loads of itself" value="1"/>
|
|
<Item label="Other nodes" value="2"/>
|
|
<Item label="Output loads of itself and other nodes" value="3"/>
|
|
</Value>
|
|
<Value type="byte" index="125" genre="config" label="Default dimming rate" units="%" min="0" max="99" value="3">
|
|
<Help>Set the default dimming rate</Help>
|
|
</Value>
|
|
<Value type="list" index="128" genre="config" label="Current working mode" units="" min="0" max="2" size="1" value="0" read_only="true">
|
|
<Help>Get the current working mode</Help>
|
|
<Item label="Unknown" value="0"/>
|
|
<Item label="2-wire mode" value="1"/>
|
|
<Item label="3-wire mode" value="2"/>
|
|
</Value>
|
|
<Value type="list" index="129" genre="config" label="Dimming principle" units="" min="0" max="1" size="1" value="1">
|
|
<Help>Set the dimming principle</Help>
|
|
<Item label="Trailing edge mode" value="0"/>
|
|
<Item label="Leading edge mode" value="1"/>
|
|
</Value>
|
|
<Value type="list" index="130" genre="config" label="Type of load" units="" min="0" max="3" size="1" value="0" read_only="true">
|
|
<Help>To get what type of load the Dimmer is connected to</Help>
|
|
<Item label="Unknown" value="0"/>
|
|
<Item label="Resistive load" value="1"/>
|
|
<Item label="Capacitive load" value="2"/>
|
|
<Item label="Inductive load" value="3"/>
|
|
</Value>
|
|
<Value type="byte" index="131" genre="config" label="Min brightness level" units="%" min="0" max="99" value="20">
|
|
<Help>Set the min brightness level that the load can reach to</Help>
|
|
</Value>
|
|
<Value type="byte" index="132" genre="config" label="Max brightness level" units="%" min="0" max="99" value="95">
|
|
<Help>Set the max brightness level that the load can reach to</Help>
|
|
</Value>
|
|
<Value type="list" index="249" genre="config" label="Recognition way of load" units="" min="0" max="2" size="1" value="2">
|
|
<Help>Set the recognition way of load</Help>
|
|
<Item label="Never recognize the load when power on" value="0"/>
|
|
<Item label="Only recognize once when first power on" value="1"/>
|
|
<Item label="Recognize the load once power on" value="2"/>
|
|
</Value>
|
|
<Value type="list" index="252" genre="config" label="Configuration Locked" units="" min="0" max="1" size="1" value="0">
|
|
<Help>Enable/disable Configuration Locked</Help>
|
|
<Item label="Disable" value="0"/>
|
|
<Item label="Enable" value="1"/>
|
|
</Value>
|
|
<Value type="list" index="255" genre="config" label="Reset To Factory Defaults" size="4" value="1" write_only="true">
|
|
<Help>Reset to factory defaults</Help>
|
|
<Item label="Reset to factory default setting" value="0"/>
|
|
<Item label="Normal" value="1"/>
|
|
<Item label="Reset to factory default setting and removed from the z-wave network" value="1431655765"/>
|
|
</Value>
|
|
</CommandClass>
|
|
<!-- Association Groups -->
|
|
<CommandClass id="133">
|
|
<Associations num_groups="4">
|
|
<Group index="1" max_associations="5" label="Lifeline"/>
|
|
<Group index="2" max_associations="5" label="Retransmit"/>
|
|
<Group index="3" max_associations="5" label="Control Key1"/>
|
|
<Group index="4" max_associations="5" label="Control Key2"/>
|
|
</Associations>
|
|
</CommandClass>
|
|
</Product>
|