<?xml version="1.0" encoding="utf-8"?>
|
|
<Product xmlns='http://code.google.com/p/open-zwave/'>
|
|
<!-- Philio Technology Corporation PH-PAT02 Multisensor 3in1 sold as Zipato brend -->
|
|
<CommandClass id="112">
|
|
<Value type="byte" genre="config" index="1" label="Basic Set OFF Level" size="1" min="0" max="255" value="0">
|
|
<Help>
|
|
Setting the BASIC command value.
|
|
When the flood trigger off(0x00), send the BASIC CC to the group 2
|
|
</Help>
|
|
</Value>
|
|
<Value type="byte" genre="config" index="2" label="Basic Set ON Level" size="1" min="0" max="255" value="255">
|
|
<Help>
|
|
Setting the BASIC command value.
|
|
When the flood trigger on(0xFF), send the BASIC CC to the group 2
|
|
</Help>
|
|
</Value>
|
|
<Value type="byte" genre="config" instance="1" index="5" label="Operation Mode" min="0" max="255" value="0">
|
|
<Help>
|
|
Bit0: Disable the Flood function.
|
|
Bit3: Setting the temperature scale. 0: Fahrenheit, 1:Celsius
|
|
Bit5: Disable the temperature report after event triggered. (1:Disable,0:Enable)
|
|
</Help>
|
|
</Value>
|
|
<Value type="byte" genre="config" instance="1" index="6" label="Multi-Sensor Function Switch" units="" min="0" max="255" value="0">
|
|
<Help>
|
|
Bit6: Disable the humidity report after event triggered. (1:Disable, 0:Enable)
|
|
</Help>
|
|
</Value>
|
|
<Value type="byte" genre="config" instance="1" index="7" label="Costumer Function" units="" min="0" max="255" value="0">
|
|
<Help>
|
|
Bit3: Disable send out BASIC OFF after the flood event cleared. (1:Disable, 0:Enable)
|
|
Bit4: Notification Type. (0: Using Notification Report, 1: Using Sensor Binary Report)
|
|
Bit5: Disable Multi CC in auto report. (1:Disable, 0:Enable)
|
|
Bit6: Disable to report battery state when the device triggered. (1:Disable, 0:Enable)
|
|
</Help>
|
|
</Value>
|
|
<Value type="byte" genre="config" instance="1" index="10" label="Auto Report Battery Time" units="" min="0" max="127" value="12">
|
|
<Help>
|
|
The interval time for auto report the battery level.
|
|
0 means turn off auto report.
|
|
The default value is 12.
|
|
The tick time can be set by the configuration No.20.
|
|
</Help>
|
|
</Value>
|
|
<Value type="byte" genre="config" instance="1" index="13" label="Auto Report Temperature Time" units="" min="0" max="127" value="12">
|
|
<Help>
|
|
The interval time for auto report the temperature.
|
|
0 means turn off auto report.
|
|
The default value is 12.
|
|
The tick time can be set by the configuration No.20.
|
|
</Help>
|
|
</Value>
|
|
<Value type="byte" genre="config" instance="1" index="14" label="Auto Report Humidity Time" units="" min="0" max="127" value="12">
|
|
<Help>
|
|
The interval time for auto report the humidity.
|
|
0 means turn off auto report.
|
|
The default value is 12.
|
|
The tick time can be set by the configuration No.20.
|
|
</Help>
|
|
</Value>
|
|
<Value type="byte" genre="config" instance="1" index="15" label="Auto Report Flood Time" units="" min="0" max="127" value="12">
|
|
<Help>
|
|
The interval time for auto report the flood state.
|
|
0 means turn off auto report.
|
|
The default value is 12.
|
|
The tick time can be set by the configuration No.20.
|
|
</Help>
|
|
</Value>
|
|
<Value type="byte" genre="config" instance="1" index="20" label="Auto Report Tick Interval" units="minute" min="0" max="255" value="30">
|
|
<Help>
|
|
The interval time for auto report each tick.
|
|
Setting this configuration will effect configuration No.10, No.13, No.14 and No.15.
|
|
Units of one minute.
|
|
Caution1: Setting to 0 means turn off all auto report function.
|
|
Caution2: The value is unsigned byte
|
|
</Help>
|
|
</Value>
|
|
|
|
<Value type="byte" genre="config" instance="1" index="21" label="Temperature Differential Report" units="fahrenheit" min="0" max="127" value="1">
|
|
<Help>
|
|
The temperature differential to report.
|
|
0 means turn off this function. The unit is Fahrenheit.
|
|
Enable this function the device will detect every 10 seconds.
|
|
And when the temperature is over 140 degree Fahrenheit, it will continue report.
|
|
</Help>
|
|
</Value>
|
|
<Value type="byte" genre="config" instance="1" index="22" label="Humidity Differential Report" units="%" min="0" max="60" value="5">
|
|
<Help>
|
|
The humidity differential to report.
|
|
0 means turn off this function.
|
|
The unit is percentage. Enable this function the device will detect every 10 seconds.
|
|
</Help>
|
|
</Value>
|
|
|
|
</CommandClass>
|
|
|
|
<!-- COMMAND_CLASS_BASIC -->
|
|
<CommandClass id="32" setasreport="true"/>
|
|
|
|
<!-- COMMAND_CLASS_ASSOCIATION -->
|
|
<CommandClass id="133">
|
|
<Associations num_groups="2">
|
|
<Group index="1" max_associations="8" label="Lifeline"/>
|
|
<Group index="2" max_associations="8" label="Light control" />
|
|
</Associations>
|
|
</CommandClass>
|
|