open-zwave/config/philio/pse02.xml

43 lines
1.6 KiB
XML

<?xml version="1.0" encoding="UTF-8"?>
<!-- Zipato: PH-PSE02.eu Indoor Siren -->
<Product xmlns="http://code.google.com/p/open-zwave/">
<!-- Configuration Parameters -->
<CommandClass id="112">
<Value type="list" index="7" genre="config" label="Customer Function" size="1" value="0">
<Help>
bit 0 Notification Type: 0: Using Notification Report, 1: Using Sensor Binary Report.
bit 7 Other sounds: 0: Disabled, 1: Enable.
</Help>
<Item label="Using Notification Report" value="0" />
<Item label="Using Sensor Binary Report" value="1" />
<Item label="Using Notification Report with other sounds" value="128"/>
<Item label="Using Sensor Binary Report with other sounds" value="129"/>
</Value>
<Value type="list" index="29" genre="config" label="Disable Alarm" size="1" value="0">
<Help>
Disable the alarm function.
1: Disable Alarm,
0: Enable Alarm.
Caution: After the power up, this configuration is always 0.
</Help>
<Item label="Enable Alarm" value="0" />
<Item label="Disable Alarm" value="1" />
</Value>
<Value type="byte" index="31" genre="config" label="Basic Set Off Level" min="0" max="127" value="6">
<Help>
Play alarm sound duration,
1 tick is 30 seconds. Default is 3 minutes, maximum is 63.5 minutes.
0 means never auto stop.
</Help>
</Value>
</CommandClass>
<!-- Basic set as report -->
<CommandClass id="32" setasreport="true"/>
<!-- Association Groups -->
<CommandClass id="133">
<Associations num_groups="1">
<Group index="1" max_associations="8" label="Lifeline"/>
</Associations>
</CommandClass>
</Product>