<?xml version="1.0" encoding="utf-8"?>
|
|
<Product xmlns='http://code.google.com/p/open-zwave/'>
|
|
<!--
|
|
Popp 700397 Wall Plug Switch Outdoor Schuko (IP44)
|
|
https://products.z-wavealliance.org/products/2842/
|
|
-->
|
|
|
|
<!-- Configuration -->
|
|
<CommandClass id="112">
|
|
<Value type="list" genre="config" instance="1" index="1" label="LED indication mode" size="1" value="1">
|
|
<Help>Defines when the LED shall shine and how</Help>
|
|
<Item label="LED off, only blinks on traffic" value="0" />
|
|
<Item label="Defined by Parameter 21 and 22" value="1" />
|
|
</Value>
|
|
|
|
<Value type="short" genre="config" instance="1" index="2" label="Automatically switch Off" size="2" units="seconds" min="0" max="65535" value="0">
|
|
<Help>
|
|
If not zero, automatically switch device off after an user defined time.
|
|
0 -> Disabled (default)
|
|
1-65535 -> Enabled time in seconds.
|
|
</Help>
|
|
</Value>
|
|
|
|
<Value type="list" genre="config" instance="1" index="3" label="Behaviour for a RF Off-Command" size="1" value="0">
|
|
<Help>
|
|
Defines how to interpret RF Off-Command.
|
|
Ignore - to switch on the light by motion detectors and switch it off after some amount of time;
|
|
in case of multiple motion detectors each would try to switch the light off that would break logic;
|
|
Switch on - to switch on the light on both On and Off paddle press on the remote and switch it off after some amount of time.
|
|
Button off click will still work (if button operations are not disabled).
|
|
</Help>
|
|
<Item label="Switch off" value="0" />
|
|
<Item label="Ignore" value="1" />
|
|
<Item label="Switch on" value="2" />
|
|
<Item label="Switch on if load is off else switch off" value="3" />
|
|
</Value>
|
|
|
|
<Value type="list" genre="config" instance="1" index="4" label="Button Mode" size="1" value="0">
|
|
<Help>This parameter defines if the local button shall control (switch) the load or it is only used to send out scene control commands to the central controller.</Help>
|
|
<Item label="Controls Load + Controls Scenes" value="0" />
|
|
<Item label="Scene Control Only" value="1" />
|
|
</Value>
|
|
|
|
<Value type="list" genre="config" instance="1" index="5" label="Restore switch state after power cycle" size="1" value="1">
|
|
<Help>Defines if the switch should restore switch state to the last prior to device power off (power cycle).</Help>
|
|
<Item label="No, turn off" value="0" />
|
|
<Item label="Yes" value="1" />
|
|
</Value>
|
|
|
|
<Value type="list" genre="config" instance="1" index="21" label="LED Color on OFF state" size="1" value="0">
|
|
<Help>Defines the behavior of the LED when the load is switched off </Help>
|
|
<Item label="Off" value="0" />
|
|
<Item label="Red" value="1" />
|
|
<Item label="Green" value="2" />
|
|
</Value>
|
|
|
|
<Value type="list" genre="config" instance="1" index="22" label="LED Color on ON state" size="1" value="2">
|
|
<Help>Defines the behavior of the LED when the load is switched on </Help>
|
|
<Item label="Off" value="0" />
|
|
<Item label="Red" value="1" />
|
|
<Item label="Green" value="2" />
|
|
</Value>
|
|
|
|
<Value type="byte" genre="config" instance="1" index="23" label="Voltage Report Threshold" size="1" units="Volt" min="0" max="250" value="100">
|
|
<Help>
|
|
Report the voltage when the voltage has changed by more then X * 1 V.
|
|
When disabled the device will report every 10 minutes regardless of current voltage.
|
|
0 -> Disabled
|
|
100 -> Default
|
|
0 - 250 -> Volt
|
|
</Help>
|
|
</Value>
|
|
|
|
<Value type="byte" genre="config" instance="1" index="24" label="Current Reporting Threshold" size="1" units="* 0,01 A" min="0" max="255" value="10">
|
|
<Help>
|
|
Report the current when the current has changed by more then X *0,01 A.
|
|
When disabled the device will report every 10 minutes regardless of current change.
|
|
0 -> Disabled
|
|
10 -> default
|
|
0 - 255 -> * 0,01 A
|
|
</Help>
|
|
</Value>
|
|
|
|
<Value type="byte" genre="config" instance="1" index="25" label="Power Reporting Threshold" size="1" units="Watts" min="0" max="255" value="50">
|
|
<Help>
|
|
Report the power when the power has changed by more then X Watt.
|
|
When disabled the device will report every 10 minutes regardless of power consumption change.
|
|
0 -> Disabled
|
|
50 -> Default
|
|
1 - 255 -> Watts
|
|
</Help>
|
|
</Value>
|
|
|
|
<Value type="short" genre="config" instance="1" index="26" label="Soft Circuit Breaker Threshold" size="2" units="Watts" min="0" max="3600" value="3600">
|
|
<Help>
|
|
When the power draw exceeds the value set in this parameter for a time set in parameter 28 the soft circuit breaker will disconnect the load.
|
|
0 -> Disabled
|
|
3600 -> Default
|
|
1 - 3600 -> Watts
|
|
</Help>
|
|
</Value>
|
|
|
|
<Value type="byte" genre="config" instance="1" index="27" label="Soft Circuit Breaker Recovery Time" size="1" units="Seconds" min="0" max="255" value="0">
|
|
<Help>Once the soft circuit breaker tipps and the load is disconnected the load will be automatically reconnected after X seconds.
|
|
When disabled the load must be repowered manually or with wireless command.
|
|
0 -> Disabled (default)
|
|
1 - 255 -> Seconds
|
|
</Help>
|
|
</Value>
|
|
|
|
<Value type="byte" genre="config" instance="1" index="28" label="Soft Circuit Breaker Recovery Time" size="1" units="* 0,1 sec" min="0" max="255" value="10">
|
|
<Help>This delay time defines how fast the soft circuit breaker wil react when the threshold power is exceeded.
|
|
The power is cut off only if the power draw remains over the threshold level for the defines time.
|
|
0 -> Disabled
|
|
10 -> Default
|
|
1 - 255 -> * 0,1 sec
|
|
</Help>
|
|
</Value>
|
|
</CommandClass>
|
|
|
|
<!-- Association Groups -->
|
|
<CommandClass id="133">
|
|
<Associations num_groups="2">
|
|
<Group index="1" max_associations="5" label="Lifeline"/>
|
|
<Group index="2" max_associations="5" label="Controlled by buttons" />
|
|
</Associations>
|
|
</CommandClass>
|
|
|
|
</Product>
|