<Product xmlns='http://code.google.com/p/open-zwave/'>
<!--
Remotec ZXT-600 AC MASTER
https://products.z-wavealliance.org/products/2445
-->
<!-- This thermostat's setpoint descriptions are 0 based, not 1 -->
<!-- COMMAND_CLASS_THERMOSTAT_SETPOINT get is not supported -->
<CommandClass id="67" base="0" getsupported="false"/>
<!-- The thermostat does not properly report its operating modes -->
<CommandClass id="64" name="COMMAND_CLASS_THERMOSTAT_MODE" version="1" request_flags="4" create_vars="true">
<Value type="list" genre="user" instance="1" index="0" label="Mode" units="" read_only="false" write_only="false" min="0" max="0" value="0">
<Item label="Off" value="0" />
<Item label="Heat" value="1" />
<Item label="Cool" value="2" />
<Item label="Resume" value="5" />
<Item label="Fan Only" value="6" />
<Item label="Dry Air" value="8" />
<Item label="Auto Changeover" value="10" />
</Value>
<SupportedModes>
<Mode index="0" label="Off" />
<Mode index="1" label="Heat" />
<Mode index="2" label="Cool" />
<Mode index="5" label="Resume" />
<Mode index="6" label="Fan Only" />
<Mode index="8" label="Dry Air" />
<Mode index="10" label="Auto Changeover" />
</SupportedModes>
</CommandClass>
<CommandClass id="112">
<Value type="list" index="25" genre="config" label="Learn IR code" size="2" min="0" max="32" value="0" write_only="true">
<Help>
In case none of the code on the code list works for the targeted air conditioner, user can use IR code learning function.
See manual at section &quot;IR Code Learning&quot; for a description of the procedure. Value 0-22
</Help>
<Item label="OFF" value="0" />
<Item label="ON (resume)" value="1" />
<Item label="Cool 17 C" value="2" />
<Item label="Cool 18 C" value="3" />
<Item label="Cool 19 C" value="4" />
<Item label="Cool 20 C" value="5" />
<Item label="Cool 21 C" value="6" />
<Item label="Cool 22 C" value="7" />
<Item label="Cool 23 C" value="8" />
<Item label="Cool 24 C" value="9" />
<Item label="Cool 25 C" value="10" />
<Item label="Cool 26 C" value="11" />
<Item label="Cool 27 C" value="12" />
<Item label="Cool 28 C" value="13" />
<Item label="Cool 29 C" value="14" />
<Item label="Cool 30 C" value="15" />
<Item label="Heat 17 C" value="16" />
<Item label="Heat 18 C" value="17" />
<Item label="Heat 19 C" value="18" />
<Item label="Heat 20 C" value="19" />
<Item label="Heat 21 C" value="20" />
<Item label="Heat 22 C" value="21" />
<Item label="Heat 23 C" value="22" />
<Item label="Heat 24 C" value="23" />
<Item label="Heat 25 C" value="24" />
<Item label="Heat 26 C" value="25" />
<Item label="Heat 27 C" value="26" />
<Item label="Heat 28 C" value="27" />
<Item label="Heat 29 C" value="28" />
<Item label="Heat 30 C" value="29" />
<Item label="Dry Mode" value="30" />
<Item label="Auto Mode" value="31" />
<Item label="Fan Mode" value="32" />
</Value>
<Value type="list" index="26" genre="config" label="Check IR Code Learning Status" size="1" read_only="true">
<Help>Note: The status value 0x01 and 0x04 will be reset to 0 when the ZXT-120 receive a get command to this parameter.
Idle - this IR channel is idle (default).
OK - the latest learning process successful and completed.
Learning - the ZXT- 120 is busy processing previous learning request.
Failed - the latest learning request failed.</Help>
<Item label="Idle" value="0" />
<Item label="OK" value="1" />
<Item label="Learning" value="2" />
<Item label="Failed" value="4" />
</Value>
<Value type="short" index="27" genre="config" label="Set IR Code number from built-in code library" size="2" value="0">
<Help>Refer to Code Finder Web page.</Help>
</Value>
<Value type="list" genre="config" instance="1" index="30" label="Set auto report condition trigger" size="1" min="0" max="8" value="0">
<Help>
Set Auto Report Condition Trigger By Room Temperature change.
Disable AUTO report function (Default) for saving battery life.
Auto report if room temperature is different from last report.
</Help>
<Item label="Disable AUTO report" value="0" />
<Item label="0.5 C" value="1" />
<Item label="1.0 C" value="2" />
<Item label="1.5 C" value="3" />
<Item label="2.0 C" value="4" />
<Item label="2.5 C" value="5" />
<Item label="3.0 C" value="6" />
<Item label="3.5 C" value="7" />
<Item label="4.0 C" value="8" />
</Value>
<Value type="list" index="32" genre="config" label="Set Built-in IR Emitter Control" size="1" value="255">
<Help>
To avoid the IR interference by disabling the surrounding IR emitter if 2 air-conditioners in a room are used.
Extend the battery life by disabling the Surround IR Emitters
</Help>
<Item label="Disable" value="0" />
<Item label="Enable" value="255" />
</Value>
<Value type="list" index="33" genre="config" label="Control Air Conditioner SWING function" size="1" value="1">
<Help></Help>
<Item label="Swing Off" value="0" />
<Item label="Swing Auto" value="1" />
</Value>
<Value type="list" genre="config" instance="1" index="34" label="Set Auto report condition by Time interval" size="1" min="1" max="8" value="1">
<Help>
Set Auto Report Condition Trigger By Time interval
</Help>
<Item label="1 Hr" value="1" />
<Item label="2 Hrs" value="2" />
<Item label="3 Hrs" value="3" />
<Item label="4 Hrs" value="4" />
<Item label="5 Hrs" value="5" />
<Item label="6 Hrs" value="6" />
<Item label="7 Hrs" value="7" />
<Item label="8 Hrs" value="8" />
</Value>
<Value type="list" genre="config" instance="1" index="37" label="Calibrate temperature reading" size="1" min="0" max="255" value="0">
<Help>
Temperature offset value.
</Help>
<Item label="0 C" value="0" />
<Item label="1 C" value="1" />
<Item label="2 C" value="2" />
<Item label="3 C" value="3" />
<Item label="4 C" value="4" />
<Item label="5 C" value="5" />
<Item label="-1 C" value="255" />
<Item label="-2 C" value="254" />
<Item label="-3 C" value="253" />
<Item label="-4 C" value="252" />
<Item label="-5 C" value="251" />
</Value>
</CommandClass>
<!-- Association Groups -->
<CommandClass id="133">
<Associations num_groups="1">
<Group index="1" max_associations="1" label="Lifeline" />
</Associations>
</CommandClass>