<?xml version="1.0" encoding="utf-8"?>
|
|
<Product xmlns='http://code.google.com/p/open-zwave/'>
|
|
<!--
|
|
Coolcam NAS-PD01ZE Motion Sensor (PIR)
|
|
http://products.z-wavealliance.org/ProductManual/File?folder=&filename=Manuals/1920/Motion%20Detector%20User%20Guide%20EU%20V3.3.pdf
|
|
-->
|
|
<!-- Configuration Parameters -->
|
|
<CommandClass id="112">
|
|
<Value type="byte" genre="config" instance="1" index="1" label="Sensitivity Level Setting" value="12" min="8" max="255" size="1">
|
|
<Help>This parameter defines the sensitivity of PIR detector, it is recommended to test the detector with movements from a farthest end of the coverage area at first time of use.
|
|
If movements cannot be detected sensitively, simply adjust the sensitivity level with this parameter.
|
|
This Parameter can be configured with the value 8 trough 255, where 8 means high sensitivity and 255 means lowest sensitivity.
|
|
</Help>
|
|
</Value>
|
|
|
|
<Value type="short" genre="config" instance="1" index="2" label="On/Off Duration" units="second" value="30" min="5" max="600" size="2">
|
|
<Help>This parameter can be determined how long the associated devices should stay ON status.
|
|
For instance, this parameter is set to 30(second), the PIR detector will send a BASIC_SET Command to an associated device with value basic set level if PIR detector is triggered and the associated device will be turned on 30(second) before it is turned off.
|
|
This Parameter value must be large than Parameter 6#.
|
|
If user set this parameter to default by Configure CC, the parameter #6 will be set to default value.
|
|
Available Settings:5 to 600(second).
|
|
</Help>
|
|
</Value>
|
|
|
|
<Value type="byte" genre="config" instance="1" index="3" label="Basic Set Level" value="255" min="0" max="255" size="1">
|
|
<Help>Basic Set Command will be sent where contains a value when PIR detector is triggered, the receiver will take it for consideration; for instance, if a lamp module is received the Basic Set Command of which value is decisive as to how bright of dim level of lamp module shall be.
|
|
This Parameter is used to some associated devices.
|
|
Available Settings: 0, 1 to 99 or 255.
|
|
</Help>
|
|
</Value>
|
|
|
|
<Value type="list" genre="config" instance="1" index="4" label="PIR Detecting Function Enabled/Disabled" value="1" size="1">
|
|
<Help>This parameter can be enabled or disabled the PIR detector detecting function.
|
|
</Help>
|
|
<Item label="Disable" value="0" />
|
|
<Item label="Enable" value="255" />
|
|
</Value>
|
|
|
|
<Value type="short" genre="config" instance="1" index="5" label="Ambient Illumination Lux Level" units="lux" value="100" min="0" max="1000" size="2">
|
|
<Help>This parameter can be set a lux level value which determines when the light sensor is activated.
|
|
If the ambient illumination level falls below this value and a person moves across or within the detected area , PIR detector will send a Z-Wave ON command(i.e. BASIC_SET (value = parameter 3) to an associated device and activate it.
|
|
0 to 1000(Lux).
|
|
</Help>
|
|
</Value>
|
|
|
|
<Value type="byte" genre="config" instance="1" index="6" label="Re-trigger Interval Setting" units="second" value="8" min="1" max="8" size="1">
|
|
<Help>This Parameter can be used to adjust the interval of being re-triggered after the PIR detector has been triggered.
|
|
This Parameter value must be less than Parameter 2#.
|
|
If user set this parameter to default by Configure CC, the parameter #2 will be set to default value.
|
|
Available Settings: 1 to 8(s).
|
|
</Help>
|
|
</Value>
|
|
|
|
<Value type="short" genre="config" instance="1" index="7" label="Light Sensor Polling Interval" units="second" value="180" min="60" max="36000" size="2">
|
|
<Help>This Parameter can be set the light sensor measure ambient illumination level interval time.
|
|
NOTE: This Value Must Be less than Wakeup Interval Time.
|
|
Available Settings: 60 ~ 36000(second).
|
|
</Help>
|
|
</Value>
|
|
|
|
<Value type="list" genre="config" instance="1" index="8" label="Lux Level Function Enable" value="0" size="1">
|
|
<Help>If this parameter is set to Enable, and when Lux level less than the value define by parameter #5, PIR detector will send a BASIC_SET command frame(i.e. BASIC_SET (value = parameter 3) to an associated device and activate it.
|
|
If Lux Level greater than the value define by parameter #5, PIR detector will not send a BASIC_SET command frame.</Help>
|
|
<Item label="Disable" value="0" />
|
|
<Item label="Enable" value="1" />
|
|
</Value>
|
|
|
|
<Value type="byte" genre="config" instance="1" index="9" label="Ambient illumination Lux Level Report" units="lux" value="100" min="0" max="255" size="1">
|
|
<Help>This parameter defines by how much Lux Level must change, in lux, to be reported to the main controller.</Help>
|
|
</Value>
|
|
|
|
<Value type="list" genre="config" instance="1" index="10" label="Led Blink Enable" value="1" size="1">
|
|
<Help>This parameter can enabled or disable the PIR led blinking function. </Help>
|
|
<Item label="Disable" value="0" />
|
|
<Item label="Enable" value="1" />
|
|
</Value>
|
|
|
|
</CommandClass>
|
|
<!-- Association Groups -->
|
|
<CommandClass id="133">
|
|
<Associations num_groups="4">
|
|
<Group index="1" max_associations="4" label="Lifeline" />
|
|
<Group index="2" max_associations="4" label="Control Commands BASIC_SET" />
|
|
<Group index="3" max_associations="4" label="Send Notification Report" />
|
|
<Group index="4" max_associations="4" label="Send Sensor Binary Report" />
|
|
</Associations>
|
|
</CommandClass>
|
|
</Product>
|