Coolcam NAS-PD01ZE Motion Sensor (PIR)
http://products.z-wavealliance.org/ProductManual/File?folder=&filename=Manuals/1920/Motion%20Detector%20User%20Guide%20EU%20V3.3.pdf
-->
<!-- Configuration Parameters -->
<CommandClass id="112">
<Value type="byte" genre="config" instance="1" index="1" label="Sensitivity Level Setting" value="12" min="8" max="255" size="1">
<Help>This parameter defines the sensitivity of PIR detector, it is recommended to test the detector with movements from a farthest end of the coverage area at first time of use.
If movements cannot be detected sensitively, simply adjust the sensitivity level with this parameter.
This Parameter can be configured with the value 8 trough 255, where 8 means high sensitivity and 255 means lowest sensitivity.
</Help>
</Value>
<Value type="short" genre="config" instance="1" index="2" label="On/Off Duration" units="second" value="30" min="5" max="600" size="2">
<Help>This parameter can be determined how long the associated devices should stay ON status.
For instance, this parameter is set to 30(second), the PIR detector will send a BASIC_SET Command to an associated device with value basic set level if PIR detector is triggered and the associated device will be turned on 30(second) before it is turned off.
This Parameter value must be large than Parameter 6#.
If user set this parameter to default by Configure CC, the parameter #6 will be set to default value.
Available Settings:5 to 600(second).
</Help>
</Value>
<Value type="byte" genre="config" instance="1" index="3" label="Basic Set Level" value="255" min="0" max="255" size="1">
<Help>Basic Set Command will be sent where contains a value when PIR detector is triggered, the receiver will take it for consideration; for instance, if a lamp module is received the Basic Set Command of which value is decisive as to how bright of dim level of lamp module shall be.
This Parameter is used to some associated devices.
Available Settings: 0, 1 to 99 or 255.
</Help>
</Value>
<Value type="list" genre="config" instance="1" index="4" label="PIR Detecting Function Enabled/Disabled" value="1" size="1">
<Help>This parameter can be enabled or disabled the PIR detector detecting function.
</Help>
<Item label="Disable" value="0" />
<Item label="Enable" value="255" />
</Value>
<Value type="short" genre="config" instance="1" index="5" label="Ambient Illumination Lux Level" units="lux" value="100" min="0" max="1000" size="2">
<Help>This parameter can be set a lux level value which determines when the light sensor is activated.
If the ambient illumination level falls below this value and a person moves across or within the detected area , PIR detector will send a Z-Wave ON command(i.e. BASIC_SET (value = parameter 3) to an associated device and activate it.
0 to 1000(Lux).
</Help>
</Value>
<Value type="byte" genre="config" instance="1" index="6" label="Re-trigger Interval Setting" units="second" value="8" min="1" max="8" size="1">
<Help>This Parameter can be used to adjust the interval of being re-triggered after the PIR detector has been triggered.
This Parameter value must be less than Parameter 2#.
If user set this parameter to default by Configure CC, the parameter #2 will be set to default value.
Available Settings: 1 to 8(s).
</Help>
</Value>
<Value type="short" genre="config" instance="1" index="7" label="Light Sensor Polling Interval" units="second" value="180" min="60" max="36000" size="2">
<Help>This Parameter can be set the light sensor measure ambient illumination level interval time.
NOTE: This Value Must Be less than Wakeup Interval Time.
Available Settings: 60 ~ 36000(second).
</Help>
</Value>
<Value type="list" genre="config" instance="1" index="8" label="Lux Level Function Enable" value="0" size="1">
<Help>If this parameter is set to Enable, and when Lux level less than the value define by parameter #5, PIR detector will send a BASIC_SET command frame(i.e. BASIC_SET (value = parameter 3) to an associated device and activate it.
If Lux Level greater than the value define by parameter #5, PIR detector will not send a BASIC_SET command frame.</Help>
<Item label="Disable" value="0" />
<Item label="Enable" value="1" />
</Value>
<Value type="byte" genre="config" instance="1" index="9" label="Ambient illumination Lux Level Report" units="lux" value="100" min="0" max="255" size="1">
<Help>This parameter defines by how much Lux Level must change, in lux, to be reported to the main controller.</Help>
</Value>
<Value type="list" genre="config" instance="1" index="10" label="Led Blink Enable" value="1" size="1">
<Help>This parameter can enabled or disable the PIR led blinking function. </Help>
<Item label="Disable" value="0" />
<Item label="Enable" value="1" />
</Value>
</CommandClass>
<!-- Association Groups -->
<CommandClass id="133">
<Associations num_groups="4">
<Group index="1" max_associations="4" label="Lifeline" />
<Group index="2" max_associations="4" label="Control Commands BASIC_SET" />
<Group index="3" max_associations="4" label="Send Notification Report" />
<Group index="4" max_associations="4" label="Send Sensor Binary Report" />
</Associations>
</CommandClass>