open-zwave/config/shenzen_neo/nas-ws02z.xml

55 lines
3.2 KiB
XML

<?xml version="1.0" encoding="utf-8"?>
<Product xmlns='http://code.google.com/p/open-zwave/'>
<!-- Configuration Parameters -->
<CommandClass id="112">
<Value type="byte" genre="config" instance="1" index="1" label="Alarm Duration Time" units="minute" value="120" min="0" max="255" size="1">
<Help>If this parameter is set to 0, the beep and LED will be turn on always until water leakage is not detected.</Help>
</Value>
<Value type="byte" genre="config" instance="1" index="2" label="Alarm Interval" units="minute" value="1" min="0" max="255" size="1">
<Help>This Parameter defines beep on/off interval time when water leakage is detected.</Help>
</Value>
<Value type="byte" genre="config" instance="1" index="3" label="First Alarm On Time Duration" units="second" value="60" min="0" max="255" size="1">
<Help>This parameter defines beep on duration first time when water leakage is detected.</Help>
</Value>
<Value type="byte" genre="config" instance="1" index="4" label="Alarm on Time Duration" units="second" value="5" min="0" max="255" size="1">
<Help>This parameter defines beep on duration after fist beep on when water leakage is detected.</Help>
</Value>
<Value type="list" genre="config" instance="1" index="5" label="Alarm sound" value="1" size="1">
<Help>This parameter defines beep on is enabled or disabled when water leakage is detected.
0 indicate beep on is disable, but LED will be turned on when water leakage detected.
1 indicate beep on is enabled, the BEEP and LED will be turned on when water leakage detected.
</Help>
<Item label="Disabled" value="0"/>
<Item label="Enabled" value="1"/>
</Value>
<Value type="list" genre="config" instance="1" index="6" label="Water Leakage Detected Report" value="1" size="1">
<Help>This parameter defines the function than water leakage detect is enabled or disabled.
0 indicate disable water leakage detect,
1 indicate enable water leakage detect.
</Help>
<Item label="Disabled" value="0"/>
<Item label="Enabled" value="1"/>
</Value>
<Value type="byte" genre="config" instance="1" index="7" label="Basic Set Level" value="255" min="0" max="255" size="1">
<Help>Basic Set Command will be sent where contains a value when the leakage is detected, the receiver will take it for consideration;
for instance, if a lamp module is received the Basic Set Command of which value is decisive as to how bright of dim level of lamp module shall be.
</Help>
</Value>
</CommandClass>
<!-- Association Groups -->
<CommandClass id="133">
<Associations num_groups="4">
<Group index="1" max_associations="4" label="Lifeline"/>
<Group index="2" max_associations="4" label="Control Commands"/>
<Group index="3" max_associations="4" label="Send Notification Report"/>
<Group index="4" max_associations="4" label="Send Binary Sensor Report"/>
</Associations>
</CommandClass>
</Product>