<?xml version="1.0" encoding="utf-8"?>
|
|
<Product xmlns="http://code.google.com/p/open-zwave/">
|
|
<!-- https://products.z-wavealliance.org/products/2243/ -->
|
|
<!-- Configuration Parameters -->
|
|
<CommandClass id="112">
|
|
<Value genre="config" instance="1" index="1" value="180" label="Light duration" units="seconds" size="2" min="5" max="900" type="short">
|
|
<Help>
|
|
Duration of light after motion detection in seconds.
|
|
</Help>
|
|
</Value>
|
|
<Value genre="config" instance="1" index="2" value="2000" label="Light threshold [lx]" units="" size="2" min="2" max="2000" type="short">
|
|
<Help>
|
|
0 - run Learn ambient light sequence.
|
|
2000 - is used as daylight (always night mode).
|
|
Value can also be controlled via potentiometer - potentiometer value is used as the default value.
|
|
</Help>
|
|
</Value>
|
|
<Value genre="config" instance="1" index="5" value="100" label="Motion Radar Sensitivity [%]" units="" size="1" min="2" max="100" type="byte">
|
|
<Help>
|
|
Adjust motion sensitivity from 2-100.
|
|
Value can also be controlled via potentiometer. Potentiometer value is used as the default value and any potentiometer movement rewrites
|
|
the current setting.
|
|
</Help>
|
|
</Value>
|
|
<Value genre="config" instance="1" index="6" value="0" label="Brightness measuring interval [min]" units="" size="1" min="5" max="120" type="byte">
|
|
<Help>
|
|
Interval for ambient light measuring when lamp is on ( lamp switches off shortly and measures ). Range 5-120 0=function is off.
|
|
</Help>
|
|
</Value>
|
|
<Value genre="config" instance="1" index="8" value="1" label="Use external Ambient Light value" units="" size="1" min="0" max="1" type="byte">
|
|
<Help>
|
|
When GLOBAL_LIGHT mode is ON - device overrides its own light sensor values and uses Light report values from any Z-Wave light sensor instead - this has to be configured appropriately to send light
|
|
automatically.
|
|
If the last remote light level value is older than 30 minutes, the internal light value is used again until the next external value is received.
|
|
</Help>
|
|
</Value>
|
|
<Value genre="config" instance="1" index="9" value="2" label="Disable local control" units="" size="1" min="0" max="4" type="list">
|
|
<Help>
|
|
Disable local control.
|
|
Lamp stops using it's own motion sensor in Slave and Stupid mode.
|
|
</Help>
|
|
<Item label="Normal mode" value="0"/>
|
|
<Item label="Slave mode without gateway checking" value="1"/>
|
|
<Item label="Normal mode with lifeline error signalisation" value="2"/>
|
|
<Item label="Slave mode with gateway checking" value="3"/>
|
|
<Item label="Stupid mode - lamp permanently on" value="4"/>
|
|
</Value>
|
|
<Value genre="config" instance="1" index="10" value="10" label="Off behaviour (timeout)" units="" size="2" min="0" max="209" type="short">
|
|
<Help>
|
|
0 - Lamp is switched off and remains so until any new motion event (local or remote) is received.
|
|
1 to 100 (Default) timeout: 1 second (1) to 100 seconds (100) in 1-second resolution.
|
|
101 to 200 timeout: 1 minute (101) to 100 minutes (200) 1-minute resolution.
|
|
201 to 209 timeout: 1 hour (201) to 9 hours (209) in 1-hour resolution.
|
|
255 Lamp is switched off for TIME (cfg 1).
|
|
It does not wait for a motion event and works normally via current motion evaluation.
|
|
</Help>
|
|
<Item value="255" label="Lamp/relay is switched off for TIME (cfg 1)"/>
|
|
</Value>
|
|
<Value genre="config" instance="1" index="11" value="255" label="On behaviour (timeout)" units="" size="2" min="2" max="209" type="short">
|
|
<Help>
|
|
Similar than Off behaviour.
|
|
Available settings: 0-255.
|
|
0 - Lamp is switched on and remains so until any new motion event (local or remote) is received.
|
|
It then works normally via current motion evaluation.
|
|
Notice - during the day, this mode cannot be ended remotely due to motion events not being transmitted only via local motion sensor if enabled.
|
|
</Help>
|
|
</Value>
|
|
<Value genre="config" instance="1" index="12" value="204" label="On behaviour time over (timeout)" units="" size="2" min="0" max="209" type="short">
|
|
<Help>
|
|
Available settings: 0-255.
|
|
0 No additional waiting for motion.
|
|
1 to 100 timeout: 1 second (1) to 100 seconds (100) in 1-second resolution.
|
|
101 to 200 timeout: 1 minute (101) to 100 minutes (200) 1-minute resolution.
|
|
201 to 209 (Default) timeout: 1 hour (201) to 9 hours (209) in 1-hour resolution.
|
|
255 Never stop waiting before motion.
|
|
</Help>
|
|
</Value>
|
|
<Value genre="config" instance="1" index="13" value="204" label="Sequence On-Off behaviour (timeout)" units="" size="2" min="0" max="209" type="short">
|
|
<Help>
|
|
Available settings: 0-255.
|
|
0 - Lamp is switched off and remains so until any new motion event (local or remote) is received.
|
|
1 to 100 timeout: 1 second (1) to 100 seconds (100) in 1-second resolution.
|
|
101 to 200 timeout: 1 minute (101) to 100 minutes (200) 1-minute resolution.
|
|
201 to 209 (Default) timeout: 1 hour (201) to 9 hours (209) in 1-hour resolution.
|
|
255 device ignores ON - OFF sequence and uses OFF behavior.
|
|
</Help>
|
|
</Value>
|
|
<Value genre="config" instance="1" index="14" value="204" label="Sequence Off-On behaviour (timeout)" units="" size="2" min="0" max="209" type="short">
|
|
<Help>
|
|
Available settings: 0-255.
|
|
0 - Lamp is switched on and remains so until any new motion event (local or remote) is received.
|
|
It then works normally via current motion evaluation.
|
|
Notice - during the day, this mode cannot be ended remotely due to motion events not being transmitted only via local motion sensor if enabled.
|
|
1 to 100 timeout: 1 second (1) to 100 seconds (100) in 1-second resolution.
|
|
101 to 200 timeout: 1 minute (101) to 100 minutes (200) 1-minute resolution.
|
|
201 to 209 (Default) timeout: 1 hour (201) to 9 hours (209) in 1-hour resolution.
|
|
255 device ignores OFF - ON sequence and uses ON behaviour.
|
|
</Help>
|
|
</Value>
|
|
<Value genre="config" instance="1" index="15" value="10" label="Sequence timing" units="" size="1" min="10" max="50" type="byte">
|
|
<Help>
|
|
Time in [100 miliseconds] of maximum delay between BASIC ON and BASIC OFF (and vice versa) to consider this as a sequence.
|
|
It is typically 1 second, but can be exceptionally longer due to retransmissions and overload in this case, a longer interval can be allowed (up to 5 seconds ).
|
|
</Help>
|
|
</Value>
|
|
<Value genre="config" instance="1" index="16" value="0" label="Motion Off behaviour (timeout)" units="" size="2" min="2" max="209" type="short">
|
|
<Help>
|
|
Available settings: 0-255.
|
|
0 (Default) BASIC SET to Motion sensor endpoint ignored, BASIC to root is mapped to relay endpoint, motion sensor still enabled.
|
|
1 to 100 timeout: 1 second (1) to 100 seconds (100) in 1-second resolution.
|
|
101 to 200 timeout: 1 minute (101) to 100 minutes (200) 1-minute resolution.
|
|
201 to 209 timeout: 1 hour (201) to 9 hours (209) in 1-hour resolution.
|
|
255 BASIC SET to Motion sensor endpoint ignored, BASIC to root is mapped to relay endpoint, motion sensor still disabled
|
|
</Help>
|
|
</Value>
|
|
</CommandClass>
|
|
|
|
<!-- Association Groups -->
|
|
<CommandClass id="133">
|
|
<Associations num_groups="4">
|
|
<Group index="1" label="Lifeline" max_associations="1" />
|
|
<Group index="2" label="Control: Key01" max_associations="16" />
|
|
<Group index="3" label="Motion Begin/End (PIR/radar/iHF)" max_associations="16" />
|
|
<Group index="4" label="Ambient light" max_associations="16" />
|
|
</Associations>
|
|
</CommandClass>
|
|
|
|