<CommandClass id="112">
<Value genre="config" instance="1" index="1" value="180" label="Light duration" units="seconds" size="2" min="5" max="900" type="short">
<Help>
Duration of light after motion detection in seconds.
</Help>
</Value>
<Value genre="config" instance="1" index="2" value="2000" label="Light threshold [lx]" units="" size="2" min="2" max="2000" type="short">
<Help>
0 - run Learn ambient light sequence.
2000 - is used as daylight (always night mode).
Value can also be controlled via potentiometer - potentiometer value is used as the default value.
</Help>
</Value>
<Value genre="config" instance="1" index="5" value="100" label="Motion Radar Sensitivity [%]" units="" size="1" min="2" max="100" type="byte">
<Help>
Adjust motion sensitivity from 2-100.
Value can also be controlled via potentiometer. Potentiometer value is used as the default value and any potentiometer movement rewrites
the current setting.
</Help>
</Value>
<Value genre="config" instance="1" index="6" value="0" label="Brightness measuring interval [min]" units="" size="1" min="5" max="120" type="byte">
<Help>
Interval for ambient light measuring when lamp is on ( lamp switches off shortly and measures ). Range 5-120 0=function is off.
</Help>
</Value>
<Value genre="config" instance="1" index="8" value="1" label="Use external Ambient Light value" units="" size="1" min="0" max="1" type="byte">
<Help>
When GLOBAL_LIGHT mode is ON - device overrides its own light sensor values and uses Light report values from any Z-Wave light sensor instead - this has to be configured appropriately to send light
automatically.
If the last remote light level value is older than 30 minutes, the internal light value is used again until the next external value is received.
</Help>
</Value>
<Value genre="config" instance="1" index="9" value="2" label="Disable local control" units="" size="1" min="0" max="4" type="list">
<Help>
Disable local control.
Lamp stops using it's own motion sensor in Slave and Stupid mode.
</Help>
<Item label="Normal mode" value="0"/>
<Item label="Slave mode without gateway checking" value="1"/>
<Item label="Normal mode with lifeline error signalisation" value="2"/>
<Item label="Slave mode with gateway checking" value="3"/>
<Item label="Stupid mode - lamp permanently on" value="4"/>
</Value>
<Value genre="config" instance="1" index="10" value="10" label="Off behaviour (timeout)" units="" size="2" min="0" max="209" type="short">
<Help>
0 - Lamp is switched off and remains so until any new motion event (local or remote) is received.
1 to 100 (Default) timeout: 1 second (1) to 100 seconds (100) in 1-second resolution.
101 to 200 timeout: 1 minute (101) to 100 minutes (200) 1-minute resolution.
201 to 209 timeout: 1 hour (201) to 9 hours (209) in 1-hour resolution.
255 Lamp is switched off for TIME (cfg 1).
It does not wait for a motion event and works normally via current motion evaluation.
</Help>
<Item value="255" label="Lamp/relay is switched off for TIME (cfg 1)"/>
</Value>
<Value genre="config" instance="1" index="11" value="255" label="On behaviour (timeout)" units="" size="2" min="2" max="209" type="short">
<Help>
Similar than Off behaviour.
Available settings: 0-255.
0 - Lamp is switched on and remains so until any new motion event (local or remote) is received.
It then works normally via current motion evaluation.
Notice - during the day, this mode cannot be ended remotely due to motion events not being transmitted only via local motion sensor if enabled.
</Help>
</Value>
<Value genre="config" instance="1" index="12" value="204" label="On behaviour time over (timeout)" units="" size="2" min="0" max="209" type="short">
<Help>
Available settings: 0-255.
0 No additional waiting for motion.
1 to 100 timeout: 1 second (1) to 100 seconds (100) in 1-second resolution.
101 to 200 timeout: 1 minute (101) to 100 minutes (200) 1-minute resolution.
201 to 209 (Default) timeout: 1 hour (201) to 9 hours (209) in 1-hour resolution.
255 Never stop waiting before motion.
</Help>
</Value>
<Value genre="config" instance="1" index="13" value="204" label="Sequence On-Off behaviour (timeout)" units="" size="2" min="0" max="209" type="short">
<Help>
Available settings: 0-255.
0 - Lamp is switched off and remains so until any new motion event (local or remote) is received.
1 to 100 timeout: 1 second (1) to 100 seconds (100) in 1-second resolution.
101 to 200 timeout: 1 minute (101) to 100 minutes (200) 1-minute resolution.
201 to 209 (Default) timeout: 1 hour (201) to 9 hours (209) in 1-hour resolution.
255 device ignores ON - OFF sequence and uses OFF behavior.
</Help>
</Value>
<Value genre="config" instance="1" index="14" value="204" label="Sequence Off-On behaviour (timeout)" units="" size="2" min="0" max="209" type="short">
<Help>
Available settings: 0-255.
0 - Lamp is switched on and remains so until any new motion event (local or remote) is received.
It then works normally via current motion evaluation.
Notice - during the day, this mode cannot be ended remotely due to motion events not being transmitted only via local motion sensor if enabled.
1 to 100 timeout: 1 second (1) to 100 seconds (100) in 1-second resolution.
101 to 200 timeout: 1 minute (101) to 100 minutes (200) 1-minute resolution.
201 to 209 (Default) timeout: 1 hour (201) to 9 hours (209) in 1-hour resolution.
255 device ignores OFF - ON sequence and uses ON behaviour.
</Help>
</Value>
<Value genre="config" instance="1" index="15" value="10" label="Sequence timing" units="" size="1" min="10" max="50" type="byte">
<Help>
Time in [100 miliseconds] of maximum delay between BASIC ON and BASIC OFF (and vice versa) to consider this as a sequence.
It is typically 1 second, but can be exceptionally longer due to retransmissions and overload in this case, a longer interval can be allowed (up to 5 seconds ).
</Help>
</Value>
<Value genre="config" instance="1" index="16" value="0" label="Motion Off behaviour (timeout)" units="" size="2" min="2" max="209" type="short">
<Help>
Available settings: 0-255.
0 (Default) BASIC SET to Motion sensor endpoint ignored, BASIC to root is mapped to relay endpoint, motion sensor still enabled.
1 to 100 timeout: 1 second (1) to 100 seconds (100) in 1-second resolution.
101 to 200 timeout: 1 minute (101) to 100 minutes (200) 1-minute resolution.
201 to 209 timeout: 1 hour (201) to 9 hours (209) in 1-hour resolution.
255 BASIC SET to Motion sensor endpoint ignored, BASIC to root is mapped to relay endpoint, motion sensor still disabled
</Help>
</Value>
</CommandClass>
<!-- Association Groups -->
<CommandClass id="133">
<Associations num_groups="4">
<Group index="1" label="Lifeline" max_associations="1" />
<Group index="2" label="Control: Key01" max_associations="16" />
<Group index="3" label="Motion Begin/End (PIR/radar/iHF)" max_associations="16" />
<Group index="4" label="Ambient light" max_associations="16" />
</Associations>
</CommandClass>