<?xml version="1.0" encoding="utf-8" ?>
|
|
<!-- Heatit Z-Dim Light Dimmer Switch (Firmware 1.0)
|
|
https://products.z-wavealliance.org/products/3261
|
|
-->
|
|
<Product xmlns='http://code.google.com/p/open-zwave/'>
|
|
|
|
<CommandClass id="112" name="COMMAND_CLASS_CONFIGURATION">
|
|
<Value type="byte" genre="config" index="1" label="Connected Load" min="0" max="200" size="1" value="0">
|
|
<Help>
|
|
This parameter defines the value of connected load.
|
|
0 Not configured (Default)
|
|
1-200 Watts connected load
|
|
</Help>
|
|
</Value>
|
|
<Value type="byte" genre="config" index="2" label="Minimum Dim level" min="1" max="98" size="1" value="20">
|
|
<Help>
|
|
This parameter defines the lowest dimming level of the dimmer.
|
|
The value must be lower than parameter 3
|
|
1-98 Default is 20 (20%)
|
|
</Help>
|
|
</Value>
|
|
<Value type="byte" genre="config" index="3" label="Maximum Dim level" min="2" max="99" size="1" value="85">
|
|
<Help>
|
|
This parameter defines the highest dimming level of the dimmer.
|
|
The value must be higher than parameter 2
|
|
2-99 Default is 85 (85%)
|
|
</Help>
|
|
</Value>
|
|
<Value type="byte" genre="config" index="4" label="Total steps" min="5" max="255" size="1" value="15">
|
|
<Help>
|
|
This parameter defines how many steps it should take to dim from minimum
|
|
to maximum dim level (One round = 20 steps)
|
|
Default is 15 (3/4 round)
|
|
</Help>
|
|
</Value>
|
|
<Value type="list" genre="config" index="5" size="1" label="Double press function" value="1">
|
|
<Help>This parameter defines the double press functionality.</Help>
|
|
<Item label="Disabled " value="0"/>
|
|
<Item label="Active (Default)" value="1"/>
|
|
</Value>
|
|
<Value type="list" genre="config" index="6" size="1" label="Scene controller" value="0">
|
|
<Help>This parameter enables scene controller.</Help>
|
|
<Item label="Central Scene notification (Default)" value="0"/>
|
|
<Item label="Dim to highest level" value="1"/>
|
|
</Value>
|
|
<Value type="byte" genre="config" index="7" label="Switch ON level" min="0" max="99" size="1" value="0">
|
|
<Help>
|
|
This parameter defines the dimming level when restored from OFF state by push button.
|
|
0 Restores last dim level (Default)
|
|
1-99%
|
|
</Help>
|
|
</Value>
|
|
<Value type="byte" genre="config" index="8" label="Dimming Duration" min="0" max="255" size="1" value="1">
|
|
<Help>
|
|
This parameter defines how long it takes to dim to desired level.
|
|
Note! Only Multilevel Switch Command Class is affected by this parameter.
|
|
0 Disabled
|
|
1-127 Duration in seconds (1 - 127 seconds. Default is 1)
|
|
128-255 Duration in minutes (1 - 127 minutes)
|
|
</Help>
|
|
</Value>
|
|
<Value type="short" genre="config" index="9" label="Meter Report Interval" min="0" max="32767" size="2" value="60">
|
|
<Help>
|
|
This parameter defines report interval for Power Metering.
|
|
0 Disabled
|
|
30-32767 Duration in seconds (Default is 60)
|
|
</Help>
|
|
</Value>
|
|
<Value type="byte" genre="config" index="10" label="Power restore level" min="1" max="99" size="1" value="50">
|
|
<Help>
|
|
Parameter defines initial dimming level after power loss.
|
|
1-99 (Default is 50%)
|
|
</Help>
|
|
</Value>
|
|
</CommandClass>
|
|
|
|
<CommandClass id="133" name="COMMAND_CLASS_ASSOCIATION">
|
|
<Associations num_groups="3">
|
|
<Group index="1" max_associations="8" label="Lifeline"/>
|
|
<Group index="2" max_associations="8" label="Dimming level"/>
|
|
<Group index="3" max_associations="8" label="State of Device ON/OFF"/>
|
|
</Associations>
|
|
</CommandClass>
|
|
|
|
</Product>
|