open-zwave/config/vision/zd2301.xml

46 lines
1.8 KiB
XML

<?xml version="1.0" encoding="utf-8"?>
<Product xmlns='http://code.google.com/p/open-zwave/'>
<!-- Vision ZD2301 Multisensor 4in1 -->
<CommandClass id="112">
<Value type="list" genre="config" index="1" label="Temperature unity" size="1" min="0" max="1" value="0">
<Help></Help>
<Item label="Celsius" value="0" />
<Item label="Fahrenheit" value="1" />
</Value>
<Value type="byte" genre="config" instance="1" index="2" label="Temperature Reporting Threshold" min="1" max="50" value="1">
<Help>Threshold change in temperature to induce an automatic report.
1 to 50 ( Set up from 0.1C to 5C)
</Help>
</Value>
<Value type="byte" genre="config" instance="1" index="3" label="Humidity Reporting Threshold" units="%" min="1" max="50" value="10">
<Help>Threshold change in humidity to induce an automatic report.
1 to 50 ( Set up from 1%-50%)
</Help>
</Value>
<Value type="byte" genre="config" instance="1" index="4" label="Luminance Reporting Threshold" units="%" min="0" max="50" value="10">
<Help>
Threshold change in luminance to induce an automatic report.
0 is disabled.
5 to 50 ( Set up from 5%-50%)
</Help>
</Value>
</CommandClass>
<!-- COMMAND_CLASS_BASIC -->
<CommandClass id="32" setasreport="true"/>
<!-- COMMAND_CLASS_ALARM AlarmCmd_Get responds with an undocumented value -->
<CommandClass id="113" getsupported="false" />
<!-- COMMAND_CLASS_SENSOR_BINARY Get responds with an undocumented value -->
<CommandClass id="30" getsupported="false" />
<!-- COMMAND_CLASS_ASSOCIATION -->
<CommandClass id="133">
<Associations num_groups="1">
<Group index="1" max_associations="5" label="Lifeline"/>
</Associations>
</CommandClass>
</Product>