author: Erik Montnémery
|
|
authorURL: https://github.com/emontnemery
|
|
title: Temperature conversions moving to SensorEntity
|
|
---
|
|
|
|
Temperature unit conversions are moving from the `Entity` base class to the `SensorEntity` base
|
|
class. Unit conversions will only be done if the sensor's `device_class` attribute is set
|
|
to `DEVICE_CLASS_TEMPERATURE`. If the `device_class` is not set or is not set to
|
|
`DEVICE_CLASS_TEMPERATURE` temperature conversion will take place during a transition
|
|
period and a warning will be logged.
|
|
|
|
To facilitate this, the sensor entity model has been updated with two new properties,
|
|
`native_value` and `native_unit_of_measurement`. This allows us to add additional
|
|
unit conversions in the future instead of relying on the integrations to do it themselves.
|
|
|
|
Sensor implementations should no longer implement the `state()` property function or set
|
|
the `_attr_state` attribute. Sensor implementations should also not implement the
|
|
`unit_of_measurement` property function, set the `_attr_unit_of_measurement` attribute
|
|
or set the `unit_of_measurement` member of `EntityDescription`.
|
|
|
|
### native_value
|
|
|
|
The value reported by the sensor.
|
|
The actual state written to the state machine may be modified by `SensorEntity` due to
|
|
unit conversions.
|
|
|
|
### native_unit_of_measurement
|
|
|
|
The unit of measurement of the sensor, if any.
|
|
The `unit_of_measurement` written to the state machine may be modified by `SensorEntity`
|
|
due to unit conversions.
|