Derive entity platforms from [`homeassistant.components.water_heater.WaterHeaterEntity`](https://github.com/home-assistant/home-assistant/blob/master/homeassistant/components/water_heater/__init__.py)
|
|
|
|
## Properties
|
|
|
|
:::tip
|
|
Properties should always only return information from memory and not do I/O (like network requests). Implement `update()` or `async_update()` to fetch data.
|
|
:::
|
|
|
|
| Name | Type | Default | Description
|
|
| --------------------- | ----------- | --------- | -----------
|
|
| `min_temp` | `float` | 110°F | The minimum temperature that can be set.
|
|
| `max_temp` | `float` | 140°F | The maximum temperature that can be set.
|
|
| `current_temperature` | `float` | `None` | The current temperature.
|
|
| `target_temperature` | `float` | `None` | The temperature we are trying to reach.
|
|
| `target_temperature_high` | `float` | `None` | Upper bound of the temperature we are trying to reach.
|
|
| `target_temperature_low` | `float` | `None` | Lower bound of the temperature we are trying to reach.
|
|
| `temperature_unit` | `str` | `NotImplementedError` | One of `TEMP_CELSIUS`, `TEMP_FAHRENHEIT`, or `TEMP_KELVIN`.
|
|
| `current_operation` | `string` | `None` | The current operation mode.
|
|
| `operation_list` | `List[str]` | `None` | List of possible operation modes.
|
|
| `supported_features` | `List[str]` | `NotImplementedError` | List of supported features.
|
|
| `is_away_mode_on` | `bool` | `None` | The current status of away mode.
|
|
|
|
The allowed operation modes are the states specified in the base component and implementations of the water_heater component cannot differ.
|
|
|
|
Properties have to follow the units defined in the `temperature_unit`.
|
|
|
|
## States
|
|
|
|
| State | Description
|
|
| ----- | -----------
|
|
| `STATE_ECO` | Energy efficient mode, provides energy savings and fast heating.
|
|
| `STATE_ELECTRIC` | Electric only mode, uses the most energy.
|
|
| `STATE_PERFORMANCE` | High performance mode.
|
|
| `STATE_HIGH_DEMAND` | Meet high demands when water heater is undersized.
|
|
| `STATE_HEAT_PUMP` | Slowest to heat, but uses less energy.
|
|
| `STATE_GAS` | Gas only mode, uses the most energy.
|
|
| `STATE_OFF` | The water heater is off.
|
|
|
|
## Supported features
|
|
|
|
Supported features are defined by using values in the `WaterHeaterEntityFeature` enum
|
|
and are combined using the bitwise or (`|`) operator.
|
|
|
|
| Value | Description |
|
|
| -------------------- | ------------------------- |
|
|
| `TARGET_TEMPERATURE` | Temperature can be set |
|
|
| `OPERATION_MODE` | Operation mode can be set |
|
|
| `AWAY_MODE` | Away mode can be set |
|
|
|
|
## Methods
|
|
|
|
### `set_temperature` or `async_set_temperature`
|
|
|
|
Sets the temperature the water heater should heat water to.
|
|
|
|
### `set_operation_mode`or `async_set_operation_mode`
|
|
|
|
Sets the operation mode of the water heater. Must be in the operation_list.
|
|
|
|
### `turn_away_mode_on` or `async_turn_away_mode_on`
|
|
|
|
Set the water heater to away mode.
|
|
|
|
### `turn_away_mode_off` or `async_turn_away_mode_off`
|
|
|
|
Set the water heater back to the previous operation mode. Turn off away mode.
|
|
|
|
### `turn_on` or `async_turn_on`
|
|
|
|
Turns the water heater on.
|
|
|
|
### `turn_off` or `async_turn_off`
|
|
|
|
Turns the water heater off.
|